• 제목/요약/키워드: field variables method

검색결과 541건 처리시간 0.029초

단축적법의 개선에 의한 축류압축기의 효과적인 성능예측 (Effective Performance Prediction of Axial Flow Compressors Using a Modified Stage-Stacking Method)

  • 송태원;김재환;김동섭;노승탁
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1077-1084
    • /
    • 2000
  • In this work, a modified stage-stacking method for the performance prediction of multi-stage axial flow compressors is proposed. The method is based on a simultaneous calculation of all interstage variables (temperature, pressure, flow velocity) instead of the conventional sequential stage-by-stage scheme. The method is also very useful in simulating the effect of changing angles of the inlet guide vane and stator vanes on the compressor operating characteristics. Generalized stage performance curves are used in presenting the performance characteristics of each stage. General assumptions enable determination of flow path data and stage design performance. Performance of various real compressors is predicted and comparison between prediction and field data validates the usefulness of the present method.

자기벡터포텐셜을 이용한 3차원 전자력 계산 (Electromagnetic Force Calculation using Magnetic Vector Potentials in 3-D Problems)

  • 양재진;이복용;이병환;이기식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.153-155
    • /
    • 1994
  • Electric machines such as motors which have moving parts are desgined for producing mechanical force or torque. The accurate calculation of electromagnetic force and torque is important in the design these machines, Electromagnetic force calculation method using the results of Finite Element Method(FEM) has been presented variously in 2-D problems. Typically the Maxwell's Stress Tensor method and the method of virtual work are used. In the problems including current source, magnetic vector potentials(MVP) have mostly been used as an unknown variables for field analysis by numerical method; e, g. FEM. This paper, thus, introduces both methods using MVP in 3-D case. To verify the usefulness of presented methods, a solenoid model is chosen and analyzed by 3-D and axisymmetrical FEM. In each case, the calculated force are tabulated for several mesh schemes.

  • PDF

스위치드 릴럭턴스 전동기의 토오크 리플 저감을 위한 기하학적인 파라미터와 전기적인 파라미터의 최적화 (Optimum Geometric and Electrical Parameter for Minimization Torque Ripple of Switched Reluctance Motor)

  • 최재학;김솔;이갑재;이주;홍경진;최동훈
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.93-100
    • /
    • 2003
  • Switched reluctance motor(SRM) has some advantages such as low cost, high torque density but SRM has essentially high torque ripple due to its salient structure. In order to apply SRM to industrial field, torque ripple has to be reduced. This paper introduces optimal design process of SRM using an optimization algorithm of Progressive Quadratic Response Surface Modeling(PQRSM) and two-dimensional(2D) Finite Element Method(FEM). The electrical and geometrical design parameters have been adopted as 2D design variables. From this work, it can be obtained both the optimal design minimized torque ripple and the optima1 design maximized the average torque, respectively. Finally, this Paper Presents Performance comparison of two optimal designs and consider influence of the selected design variables in torque characteristics.

부유식 해양구조물의 신뢰성해석 -설계변수의 불확실성 변화에 대한 구조시스템 신뢰성- (Reliability Analysis of Floating Offshore Structures -structural systems reliability to change in uncertainty of design variables-)

  • Lee, Joo-Sung
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 가을 학술발표회논문집
    • /
    • pp.224-231
    • /
    • 1993
  • This paper is concerned with the influence of changes in stochastic parameters of the important resistance variables such as the strength modelling parameter and material and geometric properties, on the system safety level of TLP structures. The effect of parameters governing the post-ultimate behaviour is also addressed. An extended incremental load method is employed for the present study, which has been successfully applied to the system reliability analysis of continuous structures. The Hutton Field TLP and its one variant called herein TLP-B, are chosen as TLP models in this paper. The results of several parameteric studies lead to useful conclusions relating to the importance of reducing uncertainties in strength formulae and relating the importance of component post-ultimate behaviour to the systems reliability of such structures.

  • PDF

조난선박의 표류거동에 관한 연구 (On the drifting characteristics of a distressed ship)

  • 김창제;채양범;김길수;정태권;강성진
    • 한국항해학회지
    • /
    • 제20권4호
    • /
    • pp.1-6
    • /
    • 1996
  • A vessel in distress might be well identified when both the variables affecting the drifting of the vessel and the extent to which the variables affect the drifted vessel are known. And also the disembarking place inside the ship might be easily located if the drifting poised is forecasted. The forecasting method of the drifting poise is resolved by combining the vectors of the current and the wind. It is, however, very hard to forecast the effect of the wind, which should be mainly determined by field survey. This study aims at identifying the drifting characteristics of medium/large ships, considering only the effect of the wind. The experiment revealed the following results. $\circled1$ The drifting poise is determined by the aspect ratio of the ship and the shape of the superstructure of the ship. $\circled2$ Drifting direction is quite stable when wind speed goes over a certain level. $\circled3$ Drifting speed is 3-7% of the wind speed in case of T/S Hannara.

  • PDF

교차검증을 이용한 국내선 항공수요예측 (Domestic air demand forecast using cross-validation)

  • 임재환;김영록;최연철;김광일
    • 한국항공운항학회지
    • /
    • 제27권1호
    • /
    • pp.43-50
    • /
    • 2019
  • The aviation demand forecast field has been actively studied along with the recent growth of the aviation market. In this study, the demand for domestic passenger demand and freight demand was estimated through cross-validation method. As a result, passenger demand is influenced by private consumption growth rate, oil price, and exchange rate. Freight demand is affected by GDP per capita, private consumption growth rate, and oil price. In particular, passenger demand is characterized by temporary external shocks, and freight demand is more affected by economic variables than temporary shocks.

신호교차로 용량 및 서비스수준에 대한 간략적 분석방법(4갈래 교차로 비포화 상태를 대상으로) (A Simplified Analytical Method for the Capacity and Level of Service of Signalized Intersections)

  • 홍순진
    • 대한교통학회지
    • /
    • 제22권4호
    • /
    • pp.43-56
    • /
    • 2004
  • 우리나라 HCM의 운영분석 과정은 많은 입력변수와 복잡한 계산절차가 요구되는 미시적인 신호교차로 분석이라고 할 수 있다. 본 연구는 4갈래 교차로 비포화 상태를 대상으로 하며, 운영분석 과정상의 교통량보정, 좌회전 및 우회전 직진환산계수 산정에 포함되는 여러 변수들 중에서 중요성이 적다고 판단되는 변수들을 통합하거나 일반화된 값을 사용함으로서 계산절차의 간략화 가능성을 검토하는 것이다. 또한 차로군 분류도 현장측정을 기초로 방향별 이동류의 교통량비로서 간략하게 분류하는 방법을 모색하였다. 연구는 해당 각 변수에 대해서 현장측정치의 최소, 최대범위에서 일반화된 값 사용시에 KHCM 분석방법을 사용하여 비교하였다. 차로군 분류에 관해서는 방향별 교통량을 변화시키면서 KHCM과 간략법을 사용하여 비교하였다. 종합평가에서는 교통량, 좌회전, 우회전 노면마찰의 최소, 최대조건을 조합하여 시나리오를 구축하고 각각의 분석방법을 사용하여 민감도를 평가하였다. 분석결과 현장에서 관측된 도로 및 교통조건에서 해당 변수의 민감도는 물론이고, 본 연구의 차로군 분류 및 종합평가의 지체차이가 오차 범위내에 있었다.

직류전기장에 의한 기포의 변형과 이탈에 관한 연구 (A Study on the Bubble Deformation and Departure Under DC Electric Field)

  • 권영철;김무환;강인석;김석준
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1518-1528
    • /
    • 1995
  • The deformation and departure processes of a bubble attached to the wall are studied experimentally and numerically to understand the phenomena of the nucleate boiling heat transfer enhancement under DC electric field. An air-bubble is injected in a dielectric liquid with different electric fields generated by changing three types of electrode system (Type 1,2 and 3) in the bubble generator. Experimental variables are the electric field strength and the distance and the shape of the electrodes under DC electric field. From experimental results, it is observed that the bubble under Dc electric field is elongated in the same direction as the electric field and the contact angle increases. For the parallel plate electrode which generates a uniform electric field, bubble departure volume doesn't seem to decrease within our experimental range. However, when a needle is raised a few millimeters from the lower electrode to make a nonuniform electric field around the needle, bubble departure volume decreases continuously with the increase of an applied voltage. The reduction effect of bubble departure volume is the most effective under a strong nonuniform electric field generated with Type 3. As the nonuniformity of the electric field due to the shape of a electrode increases, the terminal velocity and the acceleration of a bubble increase largely. For the comparison with visualization results, the deformation of a bubble attached to the electrode is carried out by a numerical method. Numerical results show good agreement qualitatively with experimental results.

$SF_6$ 가스의 실제 기체특성을 고려한 파퍼식 가스차단기 내의 냉가스 유동해석 (Analysis of Cold Gas Flow in Puffer Type GCB Considering the Real Gas Property of $SF_6$)

  • 김홍규;정진교;박경엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권3호
    • /
    • pp.129-134
    • /
    • 2004
  • To analyze the performance of the gas circuit breaker(GCB), the flow field variables such as temperature, pressure and density should be evaluated accurately In the puffer chamber of puffer type GCB, the pressure rise may Exceed 20 bar and in this range of high pressure, $SF_6$ gas deviates the ideal gas property. Therefore, the real gas property of $SF_6$ should be taken into consideration for the accurate analysis of flow field. This paper presents the analysis technique of cold gas flow in GCB employing the real gas state equation of SF6. The FVFLIC method is Employed to solve the axisymmetric Euler equation. To reduce the computational effort of real gas state equation, the relationship between density and pressure is approximated by the polynomial at the temperature of 300K. The proposed method is applied to the test GCB model and simulation results show good agreement with the experimental ones.

축류형 송풍기의 성능 및 소음 예측을 위한 전산 프로그램의 개발 및 적용 (Development and Application of the Computer Program for the Performance and Noise Prediction of Axial Flow Fan)

  • 정동규;홍순성;이찬
    • 한국유체기계학회 논문집
    • /
    • 제3권3호
    • /
    • pp.31-40
    • /
    • 2000
  • A computer program is developed for the prediction of the aerodynamic performance and the noise characteristics in the basic design step of axial flow fan. The flow field and the performance of fan are analyzed by using the streamline curvature computing scheme with total pressure loss and flow deviation models. Fan noise is assumed to be generated due to the pressure fluctuations induced by wake vortices of fan blades and to radiate via dipole distribution. The vortex-induced fluctuating pressure on blade surface is calculated by combining thin airfoil theory and the predicted flow field data. The predicted performances, sound pressure level and noise directivity patterns of fan by the present method are favorably compared with the test data of actual fan. Furthermore, the present method is shown to be very useful in optimizing design variables of fan with high efficiency and low noise level.

  • PDF