• 제목/요약/키워드: field resistance

검색결과 2,388건 처리시간 0.043초

벼 아소미노리 교배조합 품종의 벼흰잎마름병 저항성 (Resistance of Varieties Bred by Crossing with Asominori to Bacterial Leaf Blight)

  • 심재성
    • 한국자원식물학회지
    • /
    • 제10권2호
    • /
    • pp.128-134
    • /
    • 1997
  • This study was conducted to test on the resistance of varieties bred by crossing with Asominori to bacterial leaf blight. Nakdongbyeo and Dongjinbyeo which were susceptible to HB 9011, 8 resistant varieties including Ilmibyeo derived from Asominori and Asominori, Hwangok, 13 varieties including Chukoku 45 which were resistance to HB 9011, HB 9022 and HB 9033 were used to screen their res ponce depending on the various screening methods such as the true resistance, the secondary infection resistance and the disease common field test methods, and the results are as follows: Among 13 varieties tested, 11 varieties including llmibyeo showed tme resistance to HB 9011. Less than 1.0cm of disease lesion were developed on these varieties. Disease lesion was not developed on most of the Asominori lines including Daechongbyeo against IIB9011 and 1lmibyeo was also resistance to HB 9011, on this variety disease lesion area rate was 1.2%, and 7 varieties including Hwajinbyeo showed field resistance to HB 9022. Disease lesion area rate were 19.6% on Nakdongbyeo. 15.6% on Dongjinbyeo, from 3.0% to 2.4% on Asominori lines, and 0.5% on the Asominori when screened at disease common area. Disease was not developed on Keumnambyeo. Significant correlation coefficiences were found between the results from the test methods of the true resistance, the field resistance ancl the field resistance at disease common field tests on Asominori lines, but in some cases, even the varieties on which disease lesions developed, showed field resistance to HB 9022 and HB 9033.

  • PDF

소수성 특성을 이용한 저점도 AP 표면처리재의 현장 적용성 연구 (A Study on Field Applicability Evaluation of the Hydrophobic - Low Viscosity Surface Treatment Material for Pavement Preventive Maintenance)

  • 최준성
    • 한국도로학회논문집
    • /
    • 제16권1호
    • /
    • pp.31-39
    • /
    • 2014
  • PURPOSES : Surface treatment material for pavement preventive maintenance should be inspected field applicability. This study(Part II) aimed to checkup coating characteristics and performance analysis using lab and field tests. The hydrophobic - low viscosity filling material for pavement preventive maintenance is presented in Part I, which is a series of companion study. METHODS : Relative comparison between general asphalt mixtures and surface treatment asphalt mixtures are analyzed and measured for the field application such as indirect tensile strength ratio(TSR), abrasion resistance, crack propagation resistance, temperature resistance, coating thickness, permeability resistance and skid resistance in terms of british pendulum number(BPN). RESULTS : It is found that TSR, crack propagation resistance and permeability resistance is increased as against uncoated asphalt specimen. Abrasion resistance and temperature resistance is secured from the initial coating thickness point of view, which is about 0.2~0.3mm. Skid resistance on the surface treatment pavement is satisfied with the BPN criteria of national highway because of exposed aggregate and crack sill induced pavement deterioration and damage cracks. CONCLUSIONS : The hydrophobic - low viscosity surface treatment material for pavement preventive maintenance is validated on field applicability evaluation based on quantitative analysis of coating thickness and performance analysis using lab and field tests.

벼흰빛잎마름병에 대한 포장 저항성의 새로운 검정법 (An Improved Method for Screening Rice Cultivars with Field Resistance to Bacterial Leaf Blight)

  • 최재을;이두구;서재환;배성호
    • 한국식물병리학회지
    • /
    • 제1권2호
    • /
    • pp.115-121
    • /
    • 1985
  • 벼 흰빛잎마름병에 대한 새로운 포장 저항성 검정법을 모색하기 위하여 검정 식물체 접종법과 인접 식물체 접종법을 비교 검토하였다. 새로운 검정법인 검정 식물체 접종법에서는 포장 저항성 검정 식물체를 전엽접종한 발병엽으로부터 새로 출엽된 잎에 이차전염된 발병 엽면적율을 측정하였다. 검정 식물체 접종으로 검정된 포장 저항성 정도는 인접 식물체 접종 결과와 높은 상관이 인정되었으나 포장 저항성 정도는 검정 식물체 접종법에서 명확히 구분되었다. 공시한 33품종 중에서는 밀양 42호, 삼강벼, 태백벼, 한강찰벼, 섬진벼, 70 X-46, 중국 45호 등이 강한 포장 저항성을 보였다. 새로운 포장 저항성 검정법은 품종의 질적 저항성 및 포장 저항성을 동시에 검정할 수 있을 뿐만 아니라 다른 검정법에 비하여 노력과 포장 면적이 적게 들기 때문에 유용한 검정법으로 이용될 수 있을 것으로 생각된다.

  • PDF

Analysis of Magnetic Field Application Effect on Fault Current Limiting Characteristics of a Flux-lock Type SFCL

  • Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권6호
    • /
    • pp.255-259
    • /
    • 2008
  • The magnetic field application effect on resistance of a high-$T_c$ superconducting (HTSC) element comprising a flux-lock type superconducting fault current limiter (SFCL) was investigated. The YBCO thin film, which was etched into a meander line using a lithography, was used as a current limiting element of the flux-lock type SFCL. To increase the magnetic field applied into HTSC element, the capacitor was connected in series with a solenoid-type magnetic field coil installed in the third winding of the flux-lock type SFCL. There was no magnetic field application effect on the resistance of HTSC element despite the application of larger magnetic field into the HTSC element when a fault happened. The resistance of HTSC element, on the contrary, started to decrease at the point of four periods from a fault instant although the amplitude of the applied magnetic field increased.

BiPbSrCaCuO 초전도 자기검출소자 (Magnetic Field Sensor using BiPbSrCaCuO Superconductor)

  • 이상헌;이성갑;이영희
    • 한국전기전자재료학회논문지
    • /
    • 제16권5호
    • /
    • pp.429-434
    • /
    • 2003
  • The magnetic field sensor was fabricated with superconducting ceramics of BiPbSrCaCuO system. The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor was changed from zero to a value more than 100 $\mu\textrm{V}$ by the applied magnetic field. The change of electrical resistance depended on magnetic field. The sensitivity of this sensor was 2.9 $\Omega$/T. The sensing limit was about 1.5${\times}$10$\^$-5/ T. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

외부 교류자장이 Bi-2223테이프의 동저항 및 손실특성에 미치는 영향 (Effect of an External AC Magnetic field on Dynamic Resistance and Loss Characteristic in a Bi-2223 Tape)

  • 류경우;최병주
    • 한국전기전자재료학회논문지
    • /
    • 제18권5호
    • /
    • pp.473-477
    • /
    • 2005
  • A Bi-2223 tape has been developed for power applications such as a fault current limiter, a power cable and a superconducting magnetic energy storage system. In such applications, the Bi-2223 tape carries time varying transport current and in addition experiences time varying external magnetic field. It is well known that the external magnetic field not only causes magnetization loss in the Bi-2223 tape, but also drastically increases transport loss due to a so-called 'dynamic resistance' We developed an evaluation setup, which can measure transport loss in external at magnetic fields. Using this equipment, we measured the dynamic resistances for various amplitudes and frequencies of an external at magnetic field perpendicular to the face in the tape. Simultaneously we investigated the effect of an external ac field on transport loss with different experimental conditions. This paper describes test results ana discussions on correlation between the dynamic resistance and the transport loss for the Bi-2223 tape.

초전도발전기의 계자권선 보호저항 선정에 관한 연구 (Protection Resistance Determination for Field Winding in Superconducting Generator)

  • 강준선;나완수;권영길;손명환;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.238-240
    • /
    • 1999
  • In this paper, the protection resistance determination for the field winding in superconducting generator is suggested. To protect the field winding in a generator, they usually use the external resistance to decrease the field current more rapidly when quench occurs in the winding. Since the field winding is actually separated into four sections (magnets), we have choices to insert 1, 2, and 4 external resistances. For each case, the current decay and the voltages across e winding are calculated, and we can choose the best external resistance.

  • PDF

산화물 초전도체의 자기적 특성 (Magnetic Properties of Oxide Superconducting Material)

  • 이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.115-118
    • /
    • 2003
  • The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor was changed from zero to a value more than $100\;{\mu}V$ by the applied magnetic field. The change of electrical resistance depended on magnetic field. The sensitivity of this sensor was $2.9\;{\Omega}/T$. The sensing limit was about $1.5{\times}10^{-5}\;T$. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

  • PDF

BPSCCO 자기 효과 (Magnetic Characteristics of BiPbSrCaCuO Oxide Superconductor)

  • 이상헌;이성갑;이영희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.252-254
    • /
    • 2003
  • A magnetic field sensor is fabricated with superconducting ceramics system. The sensor at liquid nitrogen temperature shows the increase in electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor is changed from zero to a value more than $100{\mu}V$ by the applied magnetic field. The change in electrical resistance depends on magnetic field. The sensitivity of this sensor is 2.9 ohm/T. The increase in electrical resistance by the magnetic field is ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material.

  • PDF

하중 제어법을 이용한 파이프 줄기초의 현장 인발저항 특성 (Characteristics of Field Uplift Tests of Continuous Greenhouse using the Load Control Method)

  • 임성윤;김명환;김유용;유석철;김석진;임재삼
    • 한국농공학회논문집
    • /
    • 제60권4호
    • /
    • pp.105-111
    • /
    • 2018
  • Institutional inertia anti-disaster standard was presented mainly on the upper surface, it is necessary to improve to the soil type standard and uplift the resistance standard greenhouse that are vulnerable to strong winds. In this study, we carried out a field test using the load control method in order to evaluate the uplift resistance of continuous foundation of greenhouse with different depths of the rafters. Institutional inertia anti-disaster standard of greenhouse foundation did not protect the greenhouse structure from the damages caused by strong winds and heavy snow. Therefore, field tests for behavior characteristics of continuous greenhouse foundation were carried out to ensure stable facility cultivation. The field test condition was evaluated using different embedded depth as follows: 30cm, 40cm, 50cm and spacing 50cm, 60cm, 70 cm. As a result of the uplift resistance field tests using the load control method, the minimum uplift resistance was found to be over 90kg and uplift resistance displacement was 9.4mm. Uplift resistance of the continuous greenhouse foundation was in the range of 90-180 kg according to embedded depth and spacing. Using the test condition, there was no constant trend in the uplift resistance.