• Title/Summary/Keyword: field load test

Search Result 884, Processing Time 0.029 seconds

Review on the Fire Resistance and Pumpability Performance of Fiber Reinforced High Strength Concrete

  • Kwon, Hae-Won;Kim, Young-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.1
    • /
    • pp.58-65
    • /
    • 2013
  • Currently, many high-rise buildings are built in Korea for land-efficient utilization and vista. In high-rise buildings this tall, the use of high-strength concrete is essential to reduce the cross-section of structure members and secure axial load. However, this high strength concrete is vulnerable to spalling by fire, due to the water vapor pressure caused by the very high temperature in fire. To prevent this, the main method used is to reinforce the concrete with fiber. However, there has been little research on the pumpability of fiber reinforced high strength concrete. For this reason, this study features a performance review based on the properties and pumpability of fiber reinforced high strength concrete. In addition, the parameter of rheology was measured by extracting mortar from the concrete, and friction factor was measured through a 400 m horizontal pipe pumping test using the fiber reinforced high strength concrete. The basic information on fiber reinforced high strength concrete that we obtain through the experiments and review will contribute to the field.

A Study on the Field Test of the Solar Heating System with Parabolic Solar Collectors Integrated the Roof of a Residential Building (지붕대체형 집광집열기를 이용한 태양열 난방시스템의 동절기 성능 평가)

  • Kim, Yong-Ki;Lee, Tae-Won;Yoon, Kwang-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.61-69
    • /
    • 2007
  • The final energy consumption in the building sector in Korea represents almost 20% of the total energy consumption. Besides, Space heating and hot water generation in Korea are based on fossil fuels, with a serious environmental impact. Despite the popularity of simple solar domestic hot water systems, active solar space heating remains, for various reasons, marginal. And thus, the aim of this paper is to demonstrate potentialities of solar assisted space heating systems, both technically and economically. From this study found that the solar heating system with CPC solar collectors integrated the roof of a single-story residential building shares $50{\sim}55%$ of the annual heating load.

A Study on Fatigue Analysis of Dropper for High Speed Electric Railway (고속선용 드롭퍼 피로분석 연구)

  • Lee, Tae-Hoon;Park, Ki-Bum;Jeon, Yong-Joo;Ryu, Young-Tae;Cho, Yong-Hyeon;Lee, Ki-Won;Park, Young
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1445-1453
    • /
    • 2009
  • The dropper supports the contact wire and is attached using thimbles and various types of dropper clips on the catenary. Consequently droppers are subject to mechanical loads from friction and buckling during the passage of pantographs. If such mechanical loads occur repeatedly with every passing pantograph, it is possible that the dropper wire will break due to fatigue. In order to investigate failure causes for the high speed line dropper, theoretical analyses and experiments have been carried out. In this paper, mathematical formulas are derived for the prediction of the dropper static load. The measured values in the experiment agree well with the theoretical predictions. And, we performed measurement for the variation of forces on the dropper. To analyze the cause analysis on fracture of dropper wire, we have conducted experiment such as fatigue test of new products, SEM(Scanning Electron Microscope) and EDX(Energy Dispersive X-ray) of fractured specimens in the field. Finally, we also measured the vertical displacements when a pantograph moved at 300km/h under the Korean high speed overhead line.

  • PDF

A strengthening effect based on a grid size of a bamboo-mat and a model-test for the understanding on ground failure. (대나무매트의 격자크기에 따른 보강효과 및 지반 파괴형상 파악을 위한 모형시험)

  • Lee, Ji-Hun;Kim, Seung-Gon;Kim, Woo-Jin;Kim, Jong-Ryeol;Kang, Hee-Bog
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1673-1677
    • /
    • 2008
  • A method of construction with a basis treatment that uses a latticed bamboo mat puts bamboo's peculiarity and bamboo mat's bending substance to use, and a latticed bamboo mat equally distributes to embankment loading in a basis ground. Therefore it prevents ground destruction by an ill-balanced load and an irregular ground subsidence, and it makes safety system. This investigation make progress a soil box model by a dredged reclamation ground of west and south sea at domestic area, and make a comparative study and analyze the strengthening effect based on a grid size of a bamboo-mat and ground failure that it will use in the field.

  • PDF

Numerical and experimental study on flexural behavior of reinforced concrete beams: Digital image correlation approach

  • Krishna, B. Murali;Reddy, V. Guru Prathap;Tadepalli, T.;Kumar, P. Rathish;Lahir, Yerra
    • Computers and Concrete
    • /
    • v.24 no.6
    • /
    • pp.561-570
    • /
    • 2019
  • Understanding the realistic behavior of concrete up to failure under different loading conditions within the framework of damage mechanics and plasticity would lead to an enhanced design of concrete structures. In the present investigation, QR (Quick Response) code based random speckle pattern is used as a non-contact sensor, which is an innovative approach in the field of digital image correlation (DIC). A four-point bending test was performed on RC beams of size 1800 mm × 150 mm × 200 mm. Image processing was done using an open source Ncorr algorithm for the results obtained using random speckle pattern and QR code based random speckle pattern. Load-deflection curves of RC beams were plotted for the results obtained using both contact and non-contact (DIC) sensors, and further, Moment (M)-Curvature (κ) relationship of RC beams was developed. The loading curves obtained were used as input data for material model parameters in finite element analysis. In finite element method (FEM) based software, concrete damage plasticity (CDP) constitutive model is used to predict the realistic nonlinear quasi-static flexural behavior of RC beams for monotonic loading condition. The results obtained using QR code based DIC are observed to be on par with conventional results and FEM results.

Evaluation of Micro-Tensile Properties for Nano-coating Material TiN (나노 코팅재 TiN 의 마이크로 인장 특성 평가)

  • Huh, Yong-Hak;Kim, Dong-Iel;Hahn, Jun-Hee;Kim, Gwang-Seok;Yeon, Soon-Chang;Kim, Yong-Hyub
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.240-245
    • /
    • 2004
  • Tensile properties of hard coating material, TiN, were evaluated using micro-tensile testing system. TiN has been known as a hard coating material commonly used today. Micro-tensile testing system consisted of a micro tensile loading system and a micro-ESPI(Electronic Speckle Pattern Interferometry) system. Micro-tensile loading system had a maximum load capacity of 500mN and a resolution of 4.5 nm in stroke. TiN thin film $1{\mu}m$ thick was deposited on the Si wafer pre-deposited of $Si_3N_4$ film substrate by the closed field unbalanced magnetron sputtering (CFUBMS) process. Three kinds of micro-tensile specimen with the respective width of $50{\mu}m$, $100{\mu}m$ and $500{\mu}m$ were fabricated by MEMS process. The mechanical properties including tensile strength and elastic modulus were determined using the micro-tensile testing system and compared by those obtained by nano-indentation

  • PDF

Advanced Indentation Studies on the Effects of Hydrogen Attack on Tensile Property Degradation of Heat-Resistant Steel Heat-Affected Zones

  • Choi, Yeol;Jang, Jae-il;Lee, Yun-Hee;Kwon, Dongil;Kim, Jeong-Tae
    • Corrosion Science and Technology
    • /
    • v.2 no.6
    • /
    • pp.266-271
    • /
    • 2003
  • Safety diagnosis of various structural components and facilities is indispensable for preventing catastrophic failure of material by time-dependent and environment accelerating degradation. Also, this diagnosis of operating components should be done periodically for safe maintenance and economical repair. However, conventional standard methods for mechanical properties have the problems of bulky specimen, destructive procedure and complex procedure of specimen sampling. So, a non-destructive and simple mechanical testing method using small specimen is needed. Therefore, an advanced indentation technique was developed as a potential method for non-destructive testing of in-field structures. This technique measures indentation load-depth curve during indentation and analyzes the mechanical properties related to deformation such as yield strength, tensile strength and work-hardening index. In this paper, we characterized the tensile properties including yield and tensile strengths of the V-modified Cr-Mo steels in petro-chemical and thermo-electrical plants. And also, the effects of hydrogen-assisted degradation of the V-modified Cr-Mo steels were analyzed in terms of work-hardening index and yield ratio.

Ceramic Materials having Strain Sensing Properties -The CaO-NiO Ceramics-

  • Seo, Sato-Shi;Akira Kishimoto
    • The Korean Journal of Ceramics
    • /
    • v.5 no.2
    • /
    • pp.165-170
    • /
    • 1999
  • The strain sensing properties of th system xNiO-(1-x) CaO with various compositions (x=0.001-0.05) are evaluated and the origin of the phenomena is guessed. We have found out that the high temperature electrical conductivity of the xNiO-(1-x)CaO increases by applying the compressive stress at $1000^{\circ}C$. When the applied load is removed, the electrical conductivity rapidly decreases and returns to the original value, but a small hysteresis of the stress-conductivity curve is observed. After the loading test, the lattice parameter of the specimen is found lengthened. The correlation between the lengthening of the lattice parameter and the increases in the electrical conductivity by loading is discussed. The amount of the "expanded type" Ni(II)O6 clusters in the xNiO-(1-x)CaO grains is supposed to be increased by the applied stress, which would be the origin of the strain dependent electric conduction in the xNiO-(1-x)CaO system.aO system.

  • PDF

Frequency Control Method of Grid Interconnected Microgrid Operating in Stand Alone Mode (계통연계형 마이크로그리드의 독립운전시 주파수 제어에 관한 연구)

  • Chae, Woo-Kyu;Lee, Hak-Ju;Park, Jung-Sung;Cho, Jin-Tae;Won, Dong-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1099-1106
    • /
    • 2012
  • Microgrid is a new electrical energy system that composed of various generators, renewable energy, batteries and loads located near the electrical customers. When Microgrid is interconnected with large power system, Microgrid don't need to control the frequency. But in case of the outage or faults of power system, Microgrid should control the frequency to prevent the shutdown of Microgrid. This paper presents the frequency control methods using the droop function, being used by synchronous generators and EMS(Energy Management System). Using droop function, two battery systems could share the load based on locally measured signals without any communications between batteries. Also, we suggest that EMS should control the controllable distributed generators as P/Q control modes except batteries to overcome the weakness of droop function. Finally we suggest the two batteries systems to prolong the battery's life time considering the economical view. The validation of proposed methods is tested using PSCAD/EMTDC simulations and field test sites at the same time.

Individual DC Voltage Balancing Method at Zero Current Mode for Cascaded H-bridge Based Static Synchronous Compensator

  • Yang, Zezhou;Sun, Jianjun;Li, Shangsheng;Liao, Zhiqiang;Zha, Xiaoming
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.240-249
    • /
    • 2018
  • Individual DC voltage balance problem is an inherent issue for cascaded H-bridge (CHB) based converter. When the CHB-based static synchronous compensator (STATCOM) is operating at zero current mode, the software-based individual DC voltage balancing control techniques may not work because of the infinitesimal output current. However, the different power losses of each cell would lead to the individual DC voltages unbalance. The uneven power losses on the local supplied cell-controllers (including the control circuit and drive circuit) would especially cause the divergence of individual DC voltages, due to their characteristic as constant power loads. To solve this problem, this paper proposes an adaptive voltage balancing module which is designed in the cell-controller board with small size and low cost circuits. It is controlled to make the power loss of the cell a constant resistance load, thus the DC voltages are balanced in zero current mode. Field test in a 10kV STATCOM confirms the performance of the proposed method.