• Title/Summary/Keyword: field decay test

Search Result 25, Processing Time 0.036 seconds

Evaluation of Deterioration of Larix kaempferi Wood Heat-treated by Superheated Steam through Field Decay Test for 12 Months (12개월 야외 내후성 시험에 의한 과열증기 열처리된 낙엽송재의 열화 평가)

  • Park, Yonggun;Han, Yeonjung;Park, Jun-Ho;Chung, Hyunwoo;Kim, Hyunbin;Yang, Sang-Yun;Chang, Yoon-Seong;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.497-510
    • /
    • 2018
  • In this study, the decay resistance of larch wood, which was heat treated by superheated steam, was evaluated by the field decay test. During the field decay test of 12 months, non-treated wood has been severely damaged by termite, however, no visible damage has occurred in the preservative-treated wood and superheated steam heat-treated wood. Results of field decay test showed approximately 5% mass loss of the non-treated wood and the preservative-treated wood, and approximately 1% mass loss of the superheated steam heat-treated wood. After the field decay test for 12 months, the residual amount of preservatives remaining in the preservative-treated wood was lower than that before the field decay test. It was considered that the preservative was partially eluted during the field decay test, and the mass loss of the preservative-treated wood was thought to be similar to that of the non-treated wood. Through this study and additional long-term monitoring test, superheated steam heat treatment can be considered to be an environmental-friendly method to enhance the decay resistance of wood against rot fungi and/or insect without chemical treatment such as preservative injection.

Field Application of Power Cable Diagnosis System (전력케이블 열화진단기법의 현장적용)

  • Kim, Ju-Yong;Han, Jae-Hong;Song, Il-Keun;Kim, Sang-Jun;Lee, Jae-Bong;Oh, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

A study on charging and electrical stability characteristics with no-insulation and metal insulation in form of racetrack type coils

  • Quach, Huu Luong;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.3
    • /
    • pp.13-19
    • /
    • 2020
  • This study presents the experiment and simulation results on the magnetic field response and electrical stability behaviors of no-insulation (NI) and metal insulation with stainless steel tape (MI-SS) which wound in form of racetrack type coils. First of all, the structural design of the racetrack type bobbin was shown along with its parameters. Then, the current-voltage tests were carried out to measure the critical current of both test coils. Also, the sudden discharging and charging tests were performed in the steady state to estimate the decay field time and magnetic field response, respectively. Finally, the overcurrent tests were conducted in the transient state to investigate the electrical stability of these test coils. Based on the experimental results, the contact surface resistances were calculated and applied to the field coils (FCs) of 10-MW-class second generation high temperature superconducting generator (2G HTSG) used in wind offshore environment. The charging delay time and electrical stability for NI and MI-SS HTS FCs of 10-MW-class 2G HTSG are analyzed by the equivalent circuit model and the key parameters which were obtained from the electromagnetic finite element analysis results.

Evaluation of Preservative Efficiacy for Refractory Wood Species in Field Tests and Its Implication for Korean Wood Preservation Industry (야외시험을 통한 난주입수종의 방부성능 평가 및 국내 목재보존산업에서의 시사점)

  • Ra, Jong Bum;Ingram, Janet;Wang, Jieying;Morris, Paul I.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.544-558
    • /
    • 2017
  • The objective of this research is to investigate preservative efficacy for refractory species in field tests. The field tests were set up to evaluate the preservative performance of western hemlock and white spruce preservative-treated to the residential products group C and D of Canadian standard (CSA O80 Series-08) that have been developed for residential use in above-ground and ground-contact conditions, respectively. They were incised and pressure-treated with alkaline copper quaternary (ACQ) or copper azole (CA). Treated samples for the ground contact stake test and ground proximity test were installed in Jinju, Korea on November 2010 according to AWPA E7-09 and AWPA E18-06, respectively. Each sample has been annually assigned ratings for decay and termite attack, based on AWPA E7 grading system. After six years and five months of exposure, the untreated samples showed decay and particularly severe damage by termite attack but all the preservative-treated samples showed no decay. The results showed that the 5-mm penetration depths may be applicable for the treatment of refractory species. This paper discusses what to consider for the use of refractory species in Korean wood preservation industry from the penetration and retention points of view.

Studies on the Effect of Diffusion Process to Decay Resistance of Mine Props (간역(簡易) 처리법(處理法)에 의한 갱목(坑木)의 내부효력(耐腐效力)에 관(關)한 연구(硏究))

  • Shim, Chong-Supp;Shin, Dong-So;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.166-166
    • /
    • 1982
  • This study has been made to make an observation regarding present status of the coal mine props which is desperately needed for coal production, despite of great shortage of the timber resources in this country, and investigate the effects of diffusion process on the decay resistances of the mine props as applied preservatives of Malenit and chromated zinc chloride. The results are as follows. 1. Present status of the coal mine props Total demand of coal mine props in the year of 1975 was approximately 456 thousand cubic meters. The main species used for mine props are conifer (mainly Pinus densiflora) and hardwood (mainly Quercus). Portions between them are half and half. With non fixed specification, wide varieties of timber in size and form are used. And volume of wood used per ton of coal production shows also wide range from 0.017 cubic meter to 0.03 cubic meter. 2. Decay resistance test a) The oven dry weight decreased between untreated specimen and treated specimen has not shown any significantly, although it has shown some differences in average values between them. It may be caused by the shorter length of the test. b) The strength of compression test between untreated specimen and treated specimen has also shown the same results as shown in case of weight decrease. Reasons assumed are the same. c) The amounts of the extractives in one percent of sodium hydroxide (NaOH) between untreated and treated specimen have shown the large value in case of untreated specimen than that of treated. 3. The economical benifit between untreated and treated wood when applied in field has seen better in long tenn base in case of treated wood, although the primary cost of treated wood add a little bit more cost than that of the untreated wood.

  • PDF

A Numerical Method for Longitudinal Dispersion Equation for Nonconservative Contaminants (비보존성 오염물질에 대한 종확산 방정식의 수치해법)

  • Yu, Myeong-Gwan;Jeon, Gyeong-Su
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.6
    • /
    • pp.607-616
    • /
    • 1999
  • A fractional step finite difference model for the longitudinal dispersion of nonconservative contaminants is developed. It is based on splitting the longitudinal dispersion equation into a set of three equations each to be solved over a one-third time step. The fourth-order Holly-Preissmann scheme, an analytic solution, and the Crank-Nicholson scheme are used to solve the equations for the pure advection, the first-order decay, and the diffusion, respectively. To test the model, it is applied to simulate the longitudinal dispersion of continuous source released into a nonuniform flow field as well as the dispersion of an instantaneous source in a uniform flow field. The results are compared with the exact solution and those computed by an existing model. Compared to the existing model which uses Euler method for the first-order decay equation, the present model yield more accurate results as the decay coefficient increases.

  • PDF

A Study on the Utilization of Computer Program for the Prediction of Rom Acoustics (실내음향 예측을 위한 컴퓨터 프로그램 이용에 관한 연구)

  • 김선우;최형욱;한명호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.250-255
    • /
    • 1997
  • The computer simulation and mock-up test are recently applied to the practical design for the room acoustics to predict and evaluate its characteristics. In this paper, the sound field properties predicted and evaluated by the computer simulation were compared to the measured data. Comparison and analysis between simulation data and measured data were performed for the Reverberation Time, Sound Pressure Level at the various measuring positions and frequencies and Definition, Early Decay Time, Speech Transmission Index.

  • PDF

Influence of Copper Azole Retention Level to Wood Decay (목재 내 Copper Azole 보유량이 목재부후에 미치는 영향)

  • Lee, Hyun-Mi;Son, Dong-Won;Lee, Han-Sol;Hwang, Won-Joung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.112-121
    • /
    • 2015
  • In this study, Copper Azole (CuAz), a domestically available wood preservative for pressure treatment, was employed to perform an experimental research on its infiltration and decay properties in Japanese Red Pine. Test specimens were pressure-injected with CuAz-2 preservative to measure its preservative effectiveness, and then its impact on weight and mass losses. Furthermore, wood specimens were treated with CuAz-2 preservatives of various concentration levels before they were decayed with brown-rot-fungi in order to observe decay properties on light microscope (LM) and field emission scanning electron microscope (FE-SEM). As a result, untreated specimen by Fomitopsis palustris showed the mass loss of more than 40%, and the value of preservative effectiveness of CuAz-2 by indoor decay was $1,73-3.32kg/m^3$. The concentration levels of CuAz-2 preservative were shown to cause significant variations in terms of decay progresses in the cross section, radial section, and tangential section. By contrast, untreated specimens had underwent serious decays in early wood, late wood, longitudinal resin canals, and ray, which led to vertical destruction of wood texture. As for the radial section, ray tracheid, ray parenchyma cell, and window like pits were decayed and destroyed. In the case of tangential section, uniseriate rays and vertical resin canals were seriously decayed. In conclusion, this study indicates that the adequacy of the current CuAz injection amount should be reviewed in the domestic environment because there are significantly different decays at different decay conditions.

Development of Field Applicable Global Assessment System for Power Cable Systems (현장적응형 케이블 열화진단 설비 개발)

  • Yi, Dong-Young;Kim, Ju-Yong;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1634-1636
    • /
    • 2001
  • We have developed the global assessment system for medium voltage power cable systems. Our purpose of diagnostic activity is the economic discrimination and maintenance of bad cables which is likely to cause cable system failure. We have atapted the Voltage Decay Method to construct the power cable assessment system for our diagnostic purpose. From the field application test results, we have concluded that our system is successful and convenient for the discrimination and maintenance of the damaged cables economically.

  • PDF

A Study on the Application of GFRP Rock Bolt Sensor through Field Experiment and Numerical Analysis (현장실험과 수치해석을 통한 GFRP 록볼트 센서의 적용성 연구)

  • Lee, Seungjoo;Chang, Suk-Hyun;Lee, Kang-Il;Kim, Bumjoo;Heo, Joon;Kim, Yong-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.129-138
    • /
    • 2019
  • In this study, the rebar rock bolt sensor and GFRP rock bolt sensor, which can be monitored, were embedded in a large model slope, and the behavior of slopes occurred in the early stage of slope collapse was analyzed after performing the field failure test, numerical analysis of the individual element method and finite element method. By comparing and analyzing the field test and numerical analysis results, field applicability of rock slope collapse monitoring on the rebar rock bolt sensor and GFRP rock bolt sensor was investigated. Through this study, smart slope collapse prediction and warning system was developed, which can be used to induce effective evacuation of residents living in the collapsible area by detecting landslide and ground decay precursor information in advance.