• 제목/요약/키워드: fiber-optic sensor

검색결과 518건 처리시간 0.025초

헤테로코어형 광파이버 압력센서개발을 위한 기초연구 (A Basic Study on Development of the Hetero-core Type Fiber Optic Pressure Sensor)

  • 김영복
    • 유공압시스템학회논문집
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2010
  • A new type fiber optic sensing system has been developed as a commercially available standard using the technique of hetero-core spliced fiber optic sensor, for the purposes of monitoring large scaled structures, preserving natural environments and measuring physical phenomenons. The sensing system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed system in this work conveniently provides us with various options of sensor modules intended to measure such physical quantities as displacement, distortion, pressure, binary states and liquid adhesion. The experiment study has been performed to examine the performance to a pseudo-cracking experiment in the outdoor situation, and to clarify temperature influences to the system in terms of the coupling of optical connectors and the OTDR stability. It has been verified that the sensing system is robust to the temperature change ranging from the general condition to the hard condition. Especially, in this study, the specification and performances of the pressure sensor have been demonstrated to show the capability of inspecting various physical quantities.

  • PDF

내시경용 광섬유 pH 측정 센서 개발을 위한 기초 연구 (Feasibility Study on the Development of Fiber-Optic pH Sensor for Endoscope)

  • 이봉수;홍주영;황영묵;조승현
    • 센서학회지
    • /
    • 제13권3호
    • /
    • pp.213-217
    • /
    • 2004
  • The general method to find a H. pylori in the stomach is the rapid urease test but it is only used to decide the infection with H. pylori. In this study, it is tried to develope fiber-optic pH sensor which can be used with gastroscop to quantify H. pylori. To measure the degree of infection with H. pylori, the color change of phenol red according to the degree of pH is measured by optical fibers with different light sources and the optimum distance from a sample to the end of sensor tip is decided by measuring the maximum reflectivity from a sample. Also the sensitivity study is carried out to decide the optimum light source which has sensitive change of reflectivity to the change of pH. It is expected that the fiber-optic pH sensor which measures the degree of infection with H. pylori exactly can be developed.

광섬유 센서를 이용한 실시간 온도 감시 시스템 (Real Time Temperature Monitoring System Using Optic Fiber Sensor)

  • 이창근;김영수;구명모;김봉기
    • 한국컴퓨터정보학회논문지
    • /
    • 제15권12호
    • /
    • pp.209-216
    • /
    • 2010
  • 본 광 분포 온도 측정 시스템은 광섬유 자체를 온도 측정용 센서로 이용하는 시스템으로, 한 가닥의 광섬유만을 포설하여 포설된 주변 전체 온도를 수 천 점으로 측정이 가능한 시스템이다. 분포 측정의 경우 측정 점의 수를 많이 할 경우 측정점당 비용을 기존 센서의 비용 수준으로 절감 할 수 있으며 동시에 한 두 가닥의 광섬유로 전체 센서를 연결 할 수 있는 장점이 있다. 본 논문에서는 일반적으로 통신용으로 사용하는 광케이블 자체를 센서 (optical sensor cable)로 활용하여 최소한 매 1m 간격으로 센서 기능을 할 수 있는 특성을 이용함으로써 각 센서와 수많은 연결선들을 줄이고 시스템은 컴퓨터를 이용하여 데이터저장, 제어나 보관 등 데이터 관리가 용이하며, 실시간 온도 변화에 따른 온도 이력정보를 이용한 실시간 온도 모니터링 시스템을 구축한다.

Vibration-Monitoring of a Real Bridge by Using a $Moir\'{e}$-Fringe-Based Fiber Optic Accelerometer

  • Kim, Dae-Hyun;Lee, Jong-Jae
    • 비파괴검사학회지
    • /
    • 제27권6호
    • /
    • pp.556-562
    • /
    • 2007
  • This paper presents the use of a novel fiber optic accelerometer system to monitor ambient vibration (both wind-induced one and vehicle-induced) of a real bridge structure. This sensor system integrates the $Moir\'{e}$ fringe phenomenon with fiber optics to achieve accurate and reliable measurements. A low-cost signal processing unit implements unique algorithms to further enhance the resolution and increase the dynamic bandwidth of the sensors. The fiber optic accelerometer has two major benefits in using this fiber optic accelerometer system for monitoring civil engineering structures. One is its immunity to electromagnetic (EM) interference making it suitable for difficult applications in such environments involving strong EM fields, electrical spark-induced explosion risks, and cabling problems, prohibiting the use of conventional electromagnetic accelerometers. The other is its ability to measure both low- and high-amplitude vibrations with a constantly high resolution without pre-setting a gain level, as usually required in a conventional accelerometer. The second benefit makes the sensor system particularly useful for real-time measurement of both ambient vibration (that is often used for structural health monitoring) and strong motion such as earthquake. Especially, the semi-strong motion and the small ambient one are successfully simulated and measured by using the new fiber optic accelerometer in the experiment of the structural health monitoring of a real bridge.

Faraday 반사경을 이용한 광섬유형 전류센서의 안정화 (Stabilization of Fiber-optic Current Sensor Using a Faraday Rotator Mirror)

  • 김기혁;송민호
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.72-76
    • /
    • 2003
  • 편광분석법을 이용한 광섬유형 전류센서를 구성하여 다양한 전류측정 실험을 행하였다. 잔존 선형복굴절의 영향을 최소화하기 위하여 광섬유 센서 코일의 한쪽 끝에 Faraday 미러를 장착하였으며 일반적인 미러를 사용하는 경우와 출력의 안정성을 비교분석 하였다. 센서코일에 변형을 가하는 경우나 장시간에 걸친 안정성 실험에서도 Faraday 미러를 사용하는 경우에 출력의 안정성이 현저하게 증가함을 알 수 있었다.

광섬유 국소화 표면 플라즈몬 공명 센서를 위한 광섬유 표면상의 금속 나노 입자 형성 (Formation of metal nano particles on optical fiber for fiber optic localized surface plasmon resonance sensor)

  • 이훈;이승기
    • 센서학회지
    • /
    • 제17권2호
    • /
    • pp.95-99
    • /
    • 2008
  • Various etching methods of optical fiber and formation of metal nano particles on the optical fiber have been proposed for fabrication of fiber optic localized surface plasmon resonance (FO LSPR) biosensors. Different types of etched optical fiber are possible by removing the cladding of optical fiber using HF (hydrofluoric acid) solution and BHF (buffered hydrofluoric acid) solution, which results in improved surface roughness when BHF solution is used. Localized surface plasmon can be formed and measured by formation of silver and gold nano particles on the etched optical fiber. The characteristics of the etched optical fiber and metal nano particles on the etched surface of the optical fiber play a key role in dictating the sensitivity of the LSPR sensors, so that the proposed results can be expected to be applied for related research on fiber optic based biosensors.

Fiber-Optic Sensors

  • 김병운
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1988년도 광학 및 양자전자학 워크샵
    • /
    • pp.104-104
    • /
    • 1988
  • Single-mode 광섬유를 이용한 Sersor 및 그와 관련된 광섬유 device 의 작동원리 및 연구동향에 대하여 논의하였다. 논의된 광섬유 sersor 로는 intensity type sersor, fiber gyroscope, sensor array 등이 포함되어 있고, 관련 부품으로는 directional coupler, acousto-optic, fiber-optic amplifier 등이 설명되었다.

  • PDF

하이브리드 광섬유 센서 시스템을 이용한 풍력발전기의 다중물리량 상태감시 (A Hybrid Fiber-Optic Sensor System for Multi-Stress Condition Monitoring of Wind Turbines)

  • 김대길;김현진;송민호
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.76-82
    • /
    • 2015
  • A hybrid fiber-optic sensor system which combines fiber Bragg grating sensors and a Michelson interferometer has been constructed and evaluated for condition monitoring of large scale wind turbines. In order to measure multiple stresses applied to wind turbines such as strain, temperature and vibration, the system uses single broadband light source. It addresses both types of sensors, which simplifies the optical setup and enhances the cost-effectiveness of condition monitoring system. An athermal-packaged FBG is used to supply quasi-coherent light, of which coherence length is about 3.28mm, for the Michelson interferometer demodulation. Experimental results demonstrated that the proposed fiber-optic sensor system was capable of measuring strain and temperature with measurement accuracy of 1pm. Also 500~2000Hz vibration signals were successfully analyzed by applying FFT signal processing to interference signals.

Fiber-Optic Sensor Simultaneously Detecting Localized Surface Plasmon Resonance and Surface-Enhanced Raman Scattering

  • Norov, Erdene;Jeong, Hyeon-Ho;Park, Jae-Hyoung;Lee, Seung-Ki;Jeong, Dae Hong
    • Rapid Communication in Photoscience
    • /
    • 제2권2호
    • /
    • pp.46-51
    • /
    • 2013
  • This study reports a fiber-optic sensor detecting biomolecule by simultaneously monitoring localized surface plasmon resonance (LSPR) from gold nanoparticles (Au NPs) of ca. $50{\pm}5$ nm attached on one end of optical fiber and surface enhanced Raman scattering (SERS) of the reporter molecules adsorbed on the gold surfaces as an additional sensing tool. The sensor was fabricated by immobilizing Au NPs on one end of an optical fiber by chemical reaction. LSPR and SERS signals of the sensor were measured using various refractive indices solutions. Finally, the sensor was applied to observe real-time LSPR sensor-gram and SERS spectra of the reporter molecule of 4-aminothiphenol during the antibody-antigen reaction of interferon-gamma (IFN-${\gamma}$) as a proof-concept experiment of biological applications.

광학적 pH 센서를 위한 지시염료가 고정된 필름의 광학적 특성 연구 (Study on Optical Characteristics of pH Indicators in the Immobilized Film for Fiber-Optic pH Sensor)

  • 김범규;박병기
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.414-419
    • /
    • 2017
  • The optical characteristics of cresol red, phenol red, and neutral red immobilized in the thin film were investigated with absorbance measurement in order to find a sensing part of a fiber-optic pH sensor. Sol-Gel method with tetramethyl orthosilicate as a precursor was used to immobilize the pH indicators in the thin film. The absorbance spectra were measured when pH indicators were immobilized in the film and were dissolved in the buffer solution. Experimental results showed that the absorbance spectra could be changed when the pH indicator is immobilized in the thin film. As compared with other pH indicators, the neutral red exhibited similar absorbance spectra regardless of physical conditions and was sensitive over whole pH range between 4 and 11. In addition, the absorbance ratio of base peak to acid peak tended to increase in proportion to the increase in pH. Experimental results indicate that the neutral red is a good pH indicator for fabrication of a sensing part of the fiber-optic pH sensor.