• Title/Summary/Keyword: fiber sensor

Search Result 1,227, Processing Time 0.032 seconds

Feasibility study on the development of Liquid crystal-optical fiber temperature sensor for minimal invasive laserthermia (LC(Liquid crystal)-광섬유를 이용한 최소 침습적 레이저 온열 치료용 온도 측정 센서의 개발을 위한 기초 연구)

  • Lee, Bong-Soo;Hwang, Young-Muk;Chung, Soon-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.225-230
    • /
    • 2003
  • Nowadays, laserthermia is widely used to treat malignant tumors with generating heat as the one of minimal invasive surgeries. Generally, the laserthermia probe system consists of the fiber-optic laser and light guides, image guide and temperature sensor. It is very important to measure the temperature of treating tumor and make a stable temperature ($42{\sim}43^{\circ}C$) during the treating time. Therefore, laserthermia probe needs temperature sensor which can measure it exactly and fast. In this study, to develop a new type of temperature sensor with LC(liquid crystal) and optical fiber, the reflectivity of LC according to the temperature changes are measured. Also, the relationships are derived from the results.

Spectroscopic study on the development of fiber-optic pH sensor (광섬유 pH 센서 개발을 위한 분광학적 연구)

  • Yoo, Wook-Jae;Heo, Ji-Yeon;Cho, Dong-Hyun;Jang, Kyoung-Won;Seo, Jeong-Ki;Lee, Bong-Soo;Cho, Young-Ho;Moon, Joo-Hyun;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.365-371
    • /
    • 2009
  • In this study, we have fabricated a fiber-optic pH sensor which is composed of a light source, plastic optical fibers and a spectrometer. As an indicator, a phenol red is used, and a pH liquid solution is prepared by mixing of phenol red and various kinds of pH buffer solutions in these experiments. The emitting light from a light source is guided by plastic optical fibers to the pH liquid solution, and the optical characteristic of a light is changed in the pH liquid solution according to its color change. Therefore, we have measured the intensities and wavelength shifts of the modulated lights, which are changed due to the color variations of phenol red at different pH values, by using of a spectrometer for spectral analysis. Also, the relationships between the pH values of liquid solutions and the optical properties of modulated light according to the change of color of phenol red are obtained.

Hetero-core Optical Fiber Exposure Sensor Module and Instrumentation Delay (헤테로코어 광파이버 노출형 센서모듈과 계측 지연현상)

  • Song, Young-Yong;Park, Eik-Tae;Lee, Hwan-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.401-408
    • /
    • 2019
  • The objective of this study is to develop a new type of buried sensor module that can directly assess pre-stressed concrete by measuring strain using a hetero-core optical fiber sensor. In this regard, experiments were conducted to evaluate the performance of the sensor using an exposure sensor module. Based on the experimental results, when the values of the displacement control velocity were 0.12 mm/min and 1.80 mm/min, the corresponding delays in the measurement were 52.1 s and 2.6 s respectively, which indicated that the maximum delay between the two measurements was a factor of 19. Due to the measurement delay phenomena, the sensor module used in the experiments cannot be employed to check the real-time state of the structure. Thus, additional experiments were needed to develop a new sensor module that can measure the real-time state of the structure. To investigate the cause of the measurement delay phenomena, three experiments were conducted. It was confirmed that measurement delay is mainly attributed to frictional resistance. The measurement delay phenomena were not observed in the experiments using the friction-removed device.

Demodulation of FBG and Acoustic Sensors Embedded in a Fiber-Optic Sagnac Loop (광섬유 사낙간섭계에 삽입된 광섬유격자센서와 음향센서의 복조)

  • Kim, Hyun-Jin;Lee, June-Ho;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.44-50
    • /
    • 2012
  • When the fiber Bragg gratings are embedded in a fiber-optic Sagnac loop for measuring temperature or strain, it is difficult to separate the Bragg wavelengths. The transmitted light is mixed with the reflected Bragg wavelengths in the photo-detector, working as noises. To suppress the noises, we placed the FBG sensors and a fiber-optic attenuator at asymmetric positions in the loop. With the arrangement the reflected light became much bigger than the transmitted light, enabling the separation of the reflected Bragg wavelengths with almost the same signal-to-noise ratio of the FBG sensors outside the loop.

Winding Temperature Measurement in a 154 kV Transformer Filled with Natural Ester Fluid

  • Kweon, Dongjin;Koo, Kyosun
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.156-162
    • /
    • 2013
  • This paper measures the hot spot temperatures in a single-phase, 154 kV, 15/20 MVA power transformer filled with natural ester fluid using optical fiber sensors and compares them with those calculated by conventional heat run tests. A total of 14 optical fiber sensors were installed on the high-voltage and low-voltage windings to measure the hot spot temperatures. In addition, three thermocouples were installed in the transformer to measure the temperature distribution during the heat run tests. In the low-voltage winding, the hot spot temperature was $108.4^{\circ}C$, calculated by the conventional heat run test. However, the hot spot temperature measured using the optical fiber sensor was $129.4^{\circ}C$ between turns 2 and 3 on the upper side of the low-voltage winding. Therefore, the hot spot temperature of the low-voltage winding measured using the optical fiber sensor was $21.0^{\circ}C$ higher than that calculated by the conventional heat run test.

Fiber-optic biosensor for analysis of glucose and lactate in blood samples (혈액중 포도당과 젖산의 분석을 위한 광섬유 생물센서)

  • Sohn, Ok-Jae;Rhee, Jong-Il
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.28-33
    • /
    • 2006
  • Optical-fiber sensors have been developed to determine the concentrations of glucose and lactic acid in blood samples. Fluorescence dye [tris(2,2'-biphenyridine)-ruthenium(II)-chloride (RuBPY)] was entrapped by using a silicon to the unclad tip of a glass optic fiber. Enzymes like glucose oxidase (GOD) and lactate oxidase (LOD) have been immobilized by acrylamide resin adhesive, adsorption with zeolite or covalent bonding with aminopropyl-triethoxysilan. The fiber-optic glucose/lactate sensor was then used to analyze the concentrations of glucose and lactate in blood samples. The results were compared with the results of HPLC analysis and their difference was in error by less then 5 %.

Frequency Spectrum and re Correlation with Cutting Mechanisms in Orthogonal Cutting of Glass Fiber Reinforced Plastics (GFRP의 2차원 절삭에서 주파수 스펙트럼과 절삭메카니즘과의 상호연관성에 관한 연구)

  • Gi-Heung Choi
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.135-142
    • /
    • 2001
  • This study discusses frequency analysis based on the frequency spectrum and process characterization in orthogonal cutting of Fiber-matrix composite materials. A sparsely distributed idealized composite material, namely a glass reinforced polyester(GFRP) was used as workpiece The present method employs a force sensor and the signals from the sensor are processed using the fast Fourier transform(FFT) technique. The experimental correlations between the different chip formation mechanisms and power spectrum me established. Effects of fiber orientation, cutting parameters and tool geometry on the cutting mechanisms me also discussed.

  • PDF

A study on the computer diagnosis that apply Neural-Fuzzy algorithm accumulation detection of Partial Discharge signal (광섬유 내의 유도 브릴루앙 산란광을 이용한 초고압전력케이블 열화진단에 관한 연구)

  • Hwang, Kyoung-Jun;Yeoum, Keoung-Tae;Kim, Yong-Kab;Kim, Jin-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1558-1559
    • /
    • 2007
  • This study is an application field by using optical fiber. The system to measure sBs from optical fiber is designed, So it can be used as a temperature sensor. by using frequency shift, resulting from temperature changes. the frequency shift is checked by changing temperature from $25^{\circ}C$ to $69^{\circ}C$ with chamber in the laboratory and using 40Km optical fiber. It's also measured by varying the length of optical fiber The program to do the real-time monitoring and analyze the measured data is created to find accurate frequency. It can be used as an optical fiber sensor, which is capable of measuring temperature and distance by using sBs.

  • PDF