• Title/Summary/Keyword: femur fracture

Search Result 192, Processing Time 0.023 seconds

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

The Influence of Impact Angle on Hip Fracture in Fallings

  • Choi, Jae-Bong
    • International Journal of Safety
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • The direction of the applied load and displacement rate on the femur during falls may be an important factors in the etiology of hip fractures. Nonetheless, previous studies did not consider these two factors simultaneously for falling condition. Therefore, in the present study, an impact test system is developed to simulate the falling condition and the influence of impact angle on the deformation pattern changes of proximal femur is investigated. The results showed that a slight variation in impact angle quite affects deformation pattern of the proximal femur. Along with bone mineral density and trabaecular morphology, the impact angle can be another important factor affecting the structural capacity of the proximal femur.

Femoral Fracture load and damage localization pattern prediction based on a quasi-brittle law

  • Nakhli, Zahira;Ben Hatira, Fafa;Pithioux, Martine;Chabrand, Patrick;Saanouni, Khemais
    • Structural Engineering and Mechanics
    • /
    • v.72 no.2
    • /
    • pp.191-201
    • /
    • 2019
  • Finite element analysis is one of the most used tools for studying femoral neck fracture. Nerveless, consensus concerning either the choice of material characteristics, damage law and /or geometric models (linear on nonlinear) remains unreached. In this work, we propose a numerical quasi-brittle damage model to describe the behavior of the proximal femur associated with two methods to evaluate the Young modulus. Eight proximal femur finite elements models were constructed from CT scan data (4 donors: 3 women; 1 man). The numerical computations showed a good agreement between the numerical curves (load - displacement) and the experimental ones. A very encouraging result is obtained when a comparison is made between the computed fracture loads and the experimental ones ($R^2=0.825$, Relative error =6.49%). All specific numerical computation provided very fair qualitative matches with the fracture patterns for the sideway fall simulation. Finally, the comparative study based on 32 simulations adopting linear and nonlinear meshing led to the conclusion that the quantitatively results are improved when a nonlinear mesh is used.

Healing Effect of Yukmijihwang-tang on Fracture Factor and Morphological Changes in Femur Fractured Mice (육미지황탕(六味地黃湯)이 대퇴골절 동물모델의 골절 유합인자 및 형태학적 변화에 미치는 영향)

  • Kim, Hyun-Seok;Jeon, Dong Hwi;Oh, Min-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.4
    • /
    • pp.17-30
    • /
    • 2020
  • Objectives The purpose of this study is to evaluate the healing effect of Yukmijihwang-tang (YM) on femur fractured mice. Methods Mice were randomly divided into 6 groups: normal, control, positive control, YM with low, medium, high dosage each. All groups were prepared with femur fracture and treated diffrently. In order to measure bone regeneration effects, we analysed the levels of cyclooxygenase-2 (COX2), bone morphogenetic protein-2 (BMP2), collagen type II alpha 1 chain (Col2a1), Sox9, runt-related transcription factor 2 (Runx2), and osterix genes expressed in bone. For morphological analysis, muscles were removed and femur was observed with naked eye. Results COX2 gene expression in bone marrow significantly decreased. BMP2 gene expression significantly increased. Col2a1 gene expression significantly increased. Sox9 gene expression increased as well. Runx2 gene expression in bone marrow increased, but there was no statistical significance. Osterix gene expression significantly increased. Union of the fracture site progressed more in YM group compared to the control group. The fracture union score was significantly decreased in YM group compared to the control group. Conclusions YM showed anti-inflammatory effect, promoted bone regeneration by stimulating the bone regeneration factor. In conclusion, YM can help fracture healing and it well be applied clinically to patients with fracture.

Influence of Impact Angle on Deformation in Proximal Femur during Slide Falling (측방 낙상시의 충격 각도가 대퇴골 근위부의 변형에 미치는 영향)

  • 김병수;배태수;김정규;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.233-239
    • /
    • 2003
  • Falling related injuries are categorized as the most serious and common medical problems experienced by the elderly, hip joint fracture, one of the most serious consequences of falling in the elderly, occurs in only about 1% of falling. Nevertheless, hip fracture accounts for a considerable part of the disability, death, and medical costs associated with falling. In this study, we considered the impact angle and displacement rate in falling as another factor affecting femoral strength. Using a fresh-frozen human femur, we developed system to simulate the falling condition and then conducted the experiments changing the impact angle (0$^{\circ}$, 15$^{\circ}$, 30$^{\circ}$) of proximal femur. Also, in order to analyze the relative risk due to falling to normal situation in proximal femur, we did the static test simulating the two-legged stance condition. The results showed that the change in impact angle affected the strain distribution in proximal femur, and that a large deformation in femoral neck than in other sites. Furthermore despite low impact velocity, a large deformation in proximal femur occurred in the impact test and different strain distribution was observed compare to the static case.

Corticosteroids and Proximal Femur Fracture in Elderly Women : the KEPEC Study

  • Lee, Seung-Mi;Kim, Yoo-Ni;Youn, Kyung-Eun;Jung, Kui-Oak;Koo, Hye-Won;Bae, Jong-Myon;Park, Byung-Joo
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.236.2-237
    • /
    • 2002
  • Proximal femur fracture is known as one of the major medical problems in terms of mortality. disability and economic costs. To assess the association between the use of corticosteroids and proximal femur fracture. a cohort study was conducted upon Korean elderly women. (omitted)

  • PDF

Implementation of curved type a metallic plate system at the Bone contact (골 접촉 곡선형 금속 고정 시스템 구현)

  • Kim, Jeong-Lae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.285-292
    • /
    • 2007
  • This study was developed the metallic plate for fixation in the femur fracture for the orthopedic region and rigid fixation with plates has a firm place in fracture treatment. Most plates can be used for rigid as well as biological and dynamical fracture fixation. The device's designation and sizing has a specific with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. Short plate have a wrapping of femur and long plate have to preserve a pole of femur. The bending strength of the curved metallic long plate has to evaluate a 11,000N and The bending strength of the curved metallic short plate has to evaluate a 6,525N. The tensile stress through to press a plate is $1573N/m^2\;and\;1539N/m^2$. The device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture.

  • PDF

Stress Analysis of G-K Nail Augumentation for Femur Fractire (대퇴부 골절에 따른 금속정 보강술의 응력 해석)

  • Shin D.H.;Choi M.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.530-534
    • /
    • 2005
  • A femur occurs a fracture easily as it is broken, since it is surrounded at a thick muscle etc. But a problem of impediment by a reduction and a fixing still remains. An angumentation is recently used as a method of a fracture. We analyzed a various stress and displacement of a femur as a finite element analysis in this project. And we make certain that a profit of an augumentation existed from the result.

  • PDF

Surgical Treatment of Ipsilateral Multi-Level Femoral Fracture Treated Using Antegrade Intramedullary Nail

  • Kim, Beom-Soo;Cho, Jae-Woo;Yeo, Do-Hyun;Oh, Jong-Keon
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2018
  • Ipsilateral fractures of proximal femur with shaft and condylar region are very rare. Current concept of management is based on fixation of each fracture as independent entity using separate fixation modalities for proximal and distal parts of femur. However, we considered that antegrade femoral nailing with cephalomedullary screw fixation is a good option for ipsilateral multi-level femoral fractures. Here, we present an experience of satisfactory treatment for ipsilateral femoral neck fracture, subtrochanteric fracture, comminuted shaft fracture with supracondylar fracture following road traffic accident.