• 제목/요약/키워드: fault lines

검색결과 356건 처리시간 0.022초

풍력발전단지의 계통연계 운전이 배전선 보호계전에 미치는 영향 (Influence of the Interconnected Wind farm on Protection for Distribution Networks)

  • 장성일;김광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.151-157
    • /
    • 2003
  • Wind farm interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with wind fm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may be difficult to detect the fault happened in the distribution network connected with wind generator This paper describes the effect of the interconnected wind turbine generators on protective relaying of distribution power lines and detection of the fault occurred in a power line network. Simulation results shows that the current level of fault happened in the power line with wind farm depends on the fault impedance, the fault location. the output of wind farm. and the load condition of distribution network.

HVDC 케이블 고장점 표정 알고리즘 (Fault Location Algorithm for HVDC Cables)

  • 권영진;이동규;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.73-74
    • /
    • 2007
  • For a safe operation of HVDC systems, the fault location and clearance of faults in the HVDC lines are important. Past methods for fault location on HVDC cable depend on existence of assistance cables and fault resistance, broken cable and environment of fault location. For complement these problems, in this paper, fault location method using traveling wave and cross correlation function is proposed for HVDC cables. Voltage controlled source and current controlled source HVDC were modeled by EMTDC/PSCAD. The proposed algorithm were verified varying with fault distance, fault resistance.

  • PDF

신드롬 테스트가 용이한 대규모 MOSPLA의 설계 (Syndrome Testable Design for Large MOSPLA's)

  • ;임인칠
    • 대한전자공학회논문지
    • /
    • 제24권3호
    • /
    • pp.527-534
    • /
    • 1987
  • This paper proposes a new syndrome-testable design method for large MOSPLA's. In the conventional syndrome test method, the testing array circuit for testability is added but it has the defect that the circuit gives effect on the normal operation of the basic PLA circuit. Therefore, by adding the shift registers to the product lines of the basic MOSPLA's this defect is eliminated and the number of test patterns is decreased. In order to reduce the number of fault free syndromes to be predetermined, also, one output line, which is connected to all product lines is added. Therefore the number of output lines be observed is decreased. And the analytical method to compute fault free syndromes is presented. By unsing this method, the time and the effort to compute the syndromes are decreased.

  • PDF

MATLAB을 이용한 송전선로의 아크사고 검출 및 고장거리 추정 소프트웨어 개발에 관한 연구 (A Study on the Defection of Arcing Faults in Transmission Lines and Development of Fault Distance Estimation Software using MATLAB)

  • 김병천;박남옥;김동수;김길환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권4호
    • /
    • pp.163-168
    • /
    • 2002
  • This paper present a new verb efficient numerical algorithm for arcing faults detection and fault distance estimation in transmission line. It is based on the fundamental differential equations describing the transients on a transmission line before, during and alter the fault occurrence, and on the application of the "Least Error Squares Technique"for the unknown model parameter estimation. If the arc voltage estimated is a near zero, the fault is without arc, in other words the fault is permanent fault. If the arc voltage estimated has any high value, the faust is identified as an fault, or the transient fault. In permanent faults case, fault distance estimation is necessary. This paper uses the model of the arcing fault in transmission line using ZnO arrestor and resistance to be implemented within EMTP. One purpose of this study is to build a structure for modeling of arcing fault detection and fault distance estimation algorithm using Matlab programming. In this paper, This algorithm has been designed in Graphic user interface(GUI).

A Novel Online Multi-section Weighed Fault Matching and Detecting Algorithm Based on Wide-area Information

  • Tong, Xiaoyang;Lian, Wenchao;Wang, Hongbin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2118-2126
    • /
    • 2017
  • The large-scale power system blackouts have indicated that conventional protection relays that based on local signals cannot fit for modern power grids with complicated setting or heavily loaded-flow transfer. In order to accurately detect various faulted lines and improve the fault-tolerance of wide-area protection, a novel multi-section weighed fault matching and detecting algorithm is proposed. The real protection vector (RPV) and expected section protection vectors (ESPVs) for five fault sections are constructed respectively. The function of multi-section weighed fault matching is established to calculate the section fault matching degrees between RPV and five ESPVs. Then the fault degree of protected line based on five section fault degrees can be obtained. Two fault detecting criterions are given to support the higher accuracy rate of detecting fault. With the enumerating method, the simulation tests illustrate the correctness and fault-tolerance of proposed algorithm. It can reach the target of 100% accuracy rate under 5 bits error of wide-area protections. The influence factors of fault-tolerance are analyzed, which include the choosing of wide-area protections, as well as the topological structures of power grid and fault threshold.

Two-Terminal Numerical Algorithm for Single-Phase Arcing Fault Detection and Fault Location Estimation Based on the Spectral Information

  • Kim, Hyun-Houng;Lee, Chan-Joo;Park, Jong-Bae;Shin, Joong-Rin;Jeong, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.460-467
    • /
    • 2008
  • This paper presents a new numerical algorithm for the fault location estimation and arcing fault detection when a single-phase arcing ground fault occurs on a transmission line. The proposed algorithm derived in the spectrum domain is based on the synchronized voltage and current samples measured from the PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. In this paper, the algorithm uses DFT(Discrete Fourier Transform) for estimation. The algorithm uses a short data window for real-time transmission line protection. Also, from the calculated arc voltage amplitude, a decision can be made whether the fault is permanent or transient. The proposed algorithm is tested through computer simulation to show its effectiveness.

진행파 모드 분해 기법을 이용한 고속 고장점 표정 (A fast fault location method using modal decomposition technique of traveling wave)

  • 조경래;홍준희;김성수;강용철;박종근
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.167-174
    • /
    • 1996
  • In this paper, a fault location algorithm is presented, which uses novel signal processing techniques and takes a new paradigm to overcome some drawbacks of the conventional methods. This new method for fault location on electric power transmission lines uses only one-terminal fault signals. The main feature of the method is hat it uses the high frequency components in fault signal and considers the influence of the source network by using a traveling wave propagation characteristics. As a result, we can develop a high speed, good accuracy fault locator.

  • PDF

단선 AT 급전계통의 전차선-레일 단락 고장전류 분석 (The Analysis of Trolley-Rail Short Circuit Current in a Single Track AT Feeding System)

  • 조규정;류규상;이훈도;허승훈;김철환;권성일;김철환
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1659-1665
    • /
    • 2015
  • In general, AT(Auto-transformer) is used to improve voltage sag and inductive interference in power lines and communication lines in AC electrical railway feeding system. Especially, Korean AT feeding system has different composition compared to other countries like Japan or France, so that it has some special characteristics. However, relays imported from other countries have been used in Korea, and settings of these relays should be modified and reflect distinct characteristics of Korean AT feeding system. Therefore, study about fault analysis based on modeled AT feeding system is important. In this paper, we modeled a single track AT feeding system by using PSCAD and analyzed fault current flow in case of trolley-rail short circuit fault. Finally, we presented current magnitude of each branch expressed by boosting current of AT.

배전계통에서 1선 지락고장 시험에 의한 지락고장전류 분류에 관한 연구 (A Study on the Ground Fault Current Distribution by Single Phase-to-Neutral Fault Tests in Power Distribution System)

  • 김경철;유창훈
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.37-44
    • /
    • 2013
  • Phase to ground faults are possibly one of the maximum number of faults in power distribution system. During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multigrounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A simplified equivalent circuit model for the distribution system under case study calculated by using MATLAB gives results very close to the ground fault current distribution yielded by field tests.

효과적인 광선로 유지 보수를 위한 시스템 개발에 관한 연구 (An Study on Effective Maintenance and Operation System of Fiber Optic Lines)

  • 장은상;박갑석;김성일;최신호;이병욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.54-57
    • /
    • 1998
  • 통신망의 물리적 기반이 광케이블로 대치됨에 따라 광케이블 선로의 품질유지 및 체계적인 관리에 대한 요구도 점차 증대되고 있다. 한국통신은 광케이블 선로의 유지보수 체계를 확립하고 자동화 하기 위하여 광선로 운용 감시 시스템(FLOMS:Fiber Line Operation & Monitor System, 이하 FLOMS라 한다.)을 개발하였다. FLOMS는 광케이블 시설에 대한 체계적인 관리 및 광케이블 선로 특성시험 자동호를 통한 선로의 이상 유무를 체크하고 보고할 수 있다. 광케이블 유지보수 요원은 FLOMS 시스템을 이용하여, 운용센터에서 관리대상 전화국의 광케이블 선로들을 원격시험 할 수 있으며 기존의 광전송장치 운용관리 시스템과 연동함으로써 전송분야 운용관리의 통합관리가 가능하게 되었다. 이 시스템을 적용함으로써 광케이블 선로 고장위치의 신속한 파악에 의한 공장시간 단축, 광케이블 선로 특성의 주기적인 측정에 의한 예방보전, 광케이블 심선 정보의 전산화 관리에 의한 업무효율의 향상을 이룩하였다.

  • PDF