• 제목/요약/키워드: fault current condition

Search Result 249, Processing Time 0.031 seconds

삼상 자속구속형 한류기의 동작모드분석 (The Analysis of Operation Mode of Three-Phase Flux-Lock Type Superconducting Fault Currents Limiter)

  • 황종선;최효상;박형민;조용선;이나영;남긍현;한태희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.46-48
    • /
    • 2006
  • We investigated the analysis of operation mode of three-phase flux-lake type superconducting fault current limiter(SFCL). The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero and the SFCL has negligible influence on the power system, However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes elements of all phase-quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase.

  • PDF

Fault detection and classification of permanent magnet synchronous machine using signal injection

  • Kim, Inhwan;Lee, Younghun;Oh, Jaewook;Kim, Namsu
    • Smart Structures and Systems
    • /
    • 제29권6호
    • /
    • pp.785-790
    • /
    • 2022
  • Condition monitoring of permanent magnet synchronous motors (PMSMs) and detecting faults such as eccentricity and demagnetization are essential for ensuring system reliability. Motor current signal analysis is the most commonly used precursor for detecting faults in the PMSM drive system. However, the current signature responds sensitively to the load and temperature of the motor, thereby making it difficult to monitor faults in real- applications. Therefore, in this study, a condition monitoring methodology that detects motor faults, including their classification with standstill conditions, is proposed. The objective is to detect and classify faults of PMSMs by using programmable inverter without additional sensors and systems for detection. Both DC and AC were applied through the d-axis of a three-phase motor, and the change in incremental inductance was investigated to detect and classify faults. Simulation with finite element analysis and experiments were performed on PMSMs in healthy conditions as well as with eccentricity and demagnetization faults. Based on the results obtained from experiments, the proposed method was confirmed to detect and classify types of faults, including their severity.

웨이브렛 변환을 바탕으로 한 신경회로망을 이용한 전력용 변압기 보호 계전기법 (The protective relaying scheme of power transformer using wavelet based neural networks)

  • 권기백;윤석무;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.229-232
    • /
    • 2001
  • This paper presents the protective relaying scheme as a method for discriminating of power transform's transient state associated with magnetizng inrush state, over-exciting state and internal fault using wavelet based neural networs. The simulation of EMTP with respect to different fault, inrush condition and over-exciting condition in transformer have been conducted, and the result prove that the proposed method is able to discriminate between inrush magnetizing current and internal fault.

  • PDF

교류손실 및 안정성을 고려한 22.9kV 초전도 케이블 설계 (Design of 22.9kV High Temperature Superconducting Cable Considering AC losses and Stability)

  • 장현만;이창영;김춘동;심기덕;조전욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1210-1212
    • /
    • 2005
  • High temperature superconducting(HTS) power cable system consists of HTS cable, termination and cryogenic system. And the HTS cable consists of the former, HTS phase conductor, electric insulation, HTS shield and cryostat. Taking the advantage of HTS shield, the cold dielectric has been adopted. The phase conductor and the shield have been designed to minimize the AC loss below 1W/m/phase. The former has been designed to transport the fault current of 25kA, at fault condition. This paper describes the design process of 22.9kV HTS cable considering AC losses at normal state and the stability at fault condition.

  • PDF

미소 누전전류 검출 및 차단제어기 설계 (Development of Control Algorithm and Detection of the Small Leakage Current)

  • 반기종;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권3호
    • /
    • pp.161-165
    • /
    • 2004
  • In this paper, we have designed the ground faults detection and interrupting controller at normal condition of AC 120v to 240v rating voltage. Ground faults in electrical network have the characteristics of low current, 60㎐ frequency to 2㎑frequency. The load condition are no load and 20A load. The trip level of the controller is 6㎃ with ground faults. The Controller algorithm is implemented using pic16c71 microprocessor.

단순화된 자기차폐형 고온초전도한류기 단락 특성 해석 (The Short Circuit Analysis of a Simplified Magnetic Shielding Type High-Tc Superconducting Fault Current Limiter)

  • 이찬주;이승제;장미혜;현옥배;최효상;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.97-100
    • /
    • 1999
  • Nowadays the high-Tc Superconducting Fault current Limiter (SFCL) is one of the superconducting devices which are very closed to commercialization. The most popular model of High-Tc SFCL is a magnetic shielding type. A superconductor of magnetic shielding type SFCL can be stable in the superconducting state, because there is no contact between the superconductor and the normal conductor. But this model needs large place to set up and in a fault condition, mechanical vibrations may happen to damage the superconductor or total device. In this paper, to solve these problems, the simplified model of magnetic shielding type SFCL was introduced.

  • PDF

데이터 융합과 Dempster-Shafer 이론을 이용한 유도전동기의 결함진단 (Application of data fusion and Dempster-Skater theory in fault diagnosis of induction motors)

  • 김광진;한천;양보석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.549-555
    • /
    • 2003
  • The technology of machine condition monitoring is used effectively to detect the machine faults at an early stage using different machine quantities, such as current, voltage, temperature and vibration. Induction motors are most widely used to drive pumps, compressors and fans in industrial drives. This paper presents approach to data fusion using Dempster-Shafer theory because only one technique has uncertainty. So we can obtain advanced accuracy of the machine fault diagnosis. Vibration and current quantities are applied to diagnose three-phase induction motor.

  • PDF

초전도 배전 케이블 계통에서의 과도상태 해석 (Analysis of Transient State in the Superconducting distribution Cable Systems)

  • 김남열;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.555-557
    • /
    • 2003
  • As electric power transmission systems grow to supply the increasing electric power demand, transmission capacity is larger. but that's really difficult to secure the location for power transmission and distribution to user. The high temperature superconducting(HTS) cable is a method to solve this problem. But for applying to real systems, it needs to investigate the effect of HTS cable. The most important things is the investigation of fault condition. the fault on HTS cable include the quench state. When a fault occur in a circuit, three critical parameters(temperature, current density, magnetic field) exist. when one of these parameters exceeds the critical value, the superconducting becomes normal-conducting. f the cooling power is insufficient to recover the superconducting state, the normal-conducting zone expands. In order to solve these problem, this paper present simulate the quench state considering the over-current and over-voltage in the informal circuit and analyze the quench state.

  • PDF

3상 초전도케이블의 불평형 부하운전시 열.전류 저항에 의한 운전특성연구 (A Study on the operational characteristics of Thermal.Current Resistance of 3 phase HTS Cable under Unbalanced load operation)

  • 이근준;황시돌;이현철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.189-1-190-1
    • /
    • 2008
  • A high temperature superconducting(HTS) power cable is available for high capacity current in normal condition. But resistance was appeared to operate unbalance load by thermal current characteristic. This characteristic of HTS power cable used to design for unstated condition. And than, It used to understand and analyze characteristic of power cable thermal and critical current. This study appeared that quench resistance reason from shield and former current rise to superconductor(SC) current. The resistance of SC occurred that the cable temperature rise to fault current after decreased critical current. The quench resistance of SC increased in temperature or decreased in critical current. So the quench resistance of SC correlated with resistance of both shield and former current. It need to sufficiently influenced the parameters of HTS cable design.

  • PDF

서지보호기의 상태 감시를 위한 MOV의 고장률 예측 (Failure Rate Estimation of MOV for Condition Monitoring of Surge Protective Devices)

  • 김동진;김영선;박재준;이기식
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1302-1307
    • /
    • 2013
  • MOV(Metal Oxide Varistor) is the most important part of SPD(Surge Protective Device) which can protect electric facilities from an impulse current such as a lightning. So far, the fault of MOVs have decided only by surge count without considering magnitude of surge current and an amount of input energy. This paper proposed the fault prediction algorithm for the MOV using look up table made by surge count and input current data which have non-linear characteristics for input current and are estimated by high voltage experimental results. Proposed algorithm was proved by experiment on verification at a high voltage laboratory.