• Title/Summary/Keyword: fault current characteristics

Search Result 607, Processing Time 0.03 seconds

Extension of Cut-off Capacity of DC Circuit Breaker due to Superconducting Coil Application (초전도 코일 적용으로 인한 DC 차단기의 차단 용량 증대)

  • Choi, Hye-Won;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.4
    • /
    • pp.593-597
    • /
    • 2019
  • We proposed a current Interruption type DC superconducting circuit breaker(I-DC SCB), a protection device that combines the current limiting technology of a superconductor with the cut-off technology of circuit breaker. Unlike existing protective devices, the current I-DC SCB is a device that combines two protection functions, notably improving failure probability and operational reliability. It is also applicable to all DC systems, such as HV, MV, and LVDC, due to the ease in capacity increase. The 100 kV I-DC SCB was designed after taking into account the actual power system conditions, followed by an analysis of the transient characteristics and the breaking range of the limiter. The results of the analysis showed that the I-DC SCB had a fault current limit of about 75% at the rated voltage, and completed the cut-off operation within about 20 ms.

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

Thermal Flow Characteristics of Gas Circuit Breakers near Current Zero Period (가스차단기 전류영점영역에서의 열유동특성에 관한 연구)

  • Lee, Jong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1772-1774
    • /
    • 2004
  • Because the physics occurring during an interruption process is not well known, it is not easy to analyze the characteristics of a self-blast circuit breaker neither theoretically nor experimentally. Fortunately the available computational power and the numerical method improved recently make it possible to predict an interruption process as precisely and fast as possible. Therefore many researches using computational methods have been done for the interruption process of interrupters and applied to extend the information such as thermal and dielectric reignition. In this paper, we have simulated the interruption process of SF6 self-blast circuit breakers with the arc plasma during the fault interruption of a 10 kA current. The CFD program used here is coupled with the electromagnetic field analysis, the radiation model and the effects of turbulence. Through this work, we have get further information about the thermal performance as well as the behavior of the arc. The results have been compared with the measured arc voltage.

  • PDF

Torque ripple control of High Current SRM using Fuzzy Controller (퍼지제어기를 이용한 대전류 SRM의 토크리플제어)

  • OH, Dong-Jun;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.373-375
    • /
    • 2004
  • The SRM is more robust and lower cost than other type motors. The inverter for SRM cannot have shoot through fault, since a phase winding of SRM is independent of other phase windings. The SRM has high starting torque and high power density. But it has torque ripples due to nonlinear magnetic characteristics. Therefore, SRM has highly non-linear torque producing characteristics. Because fuzzy logic is a flexible and general-purposed method for implementing non-linear dynamic functions, it is effective for the control of high current SRM. We design the fuzzy controller and demonstrate the fuzzy control system by MATLAB.

  • PDF

Characteristics of Prototype Solenoid for Basic Design of DC Reactor Type SFCL (유도형 고온초전도한류기의 DC 리액터 설계를 위한 솔레노이드 특성실험)

  • 김민철;안민철;이승제;김영식;김진기;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.213-215
    • /
    • 2003
  • This paper deals with the characteristics of a prototype solenoid for basic design of DC reactor type superconducting fault current limiter (SFCL). The prototype high-Tc Super-conducting (HTS) solenoid was manufactured with 4 stacked Bi-2223 tape. The critical currents were measured with respect to the number of stacks. In order to test the safety of HTS solenoid in quenched state, the transport tests of AC over-current were performed. These experimental results could be applied to the basic design of HTS DC reactor for SFCL effectively.

  • PDF

Electrical Characteristics of the Interfacial Layer between XLPE/EPDM Laminates on the Heat Treatment (열처리 조건에 따른 XLPE / EPDM 계면의 전기적 특성)

  • 최원창;이제정;김석기;조대식;한상옥;박강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.225-228
    • /
    • 1997
  • The main fault in this interface is that power cable insulating materials are mainly composed of a double layered structure, XLPE/FPDM laminates in cable joint. In this parer, we instituted the interface of XLPE/EPDM laminates and then investigated the breakdown and conduction characteristics as a function of heat treatment time. The results showed that conduction current was influenced by volatile crosslinking by-products which remained inside the insulating material during the production of XLPE and EPDM, especially during heat treatment process. And conduction current of XLPE/Oil 12500cSt/EPDM was more stable than XLPE/Grease/EPDM from the long heat treatment time. AC breakdown strength of silicone oil itself from the heat treatment was changed during the 4∼12 hour heat treatment time.

  • PDF

Current Limiting Characteristics of transformer type SFCL using neutral line (중성점을 이용한 변압기형 초전도 한류기의 전류제한 특성 분석)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Park, Hyoung-Min;Lee, Ju-Hyoung;Jung, Byung-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2090-2091
    • /
    • 2007
  • We investigated the characteristics of transformer type SFCL with neutral line. The transformer type SFCL having neutral line has achieved the simultaneous quench because the secondary winding has acted as parallel reactor. The fault current of SFCL was limited according to ratio of turn number between primary and secondary windings. Therefore, the power burden of superconducting element can be reduced by reduction of ratio of turn number between primary and secondary windings. As a result, we could expect reduction of it's volume in the transformer type SFCL.

  • PDF

A Study on the Grounding Impedance Effects and Its Characteristics (접지 임피던스의 영향분석에 관한 연구)

  • Chang, Myong-Soo;Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1948-1949
    • /
    • 2007
  • This paper presents the characteristics and effects of grounding resistor and impedance. In grounding system, Grounding resistor is governed neutral currents and voltage. It seems that, grounding resistor has 0 value, then circuit has no faults. While if grounding resistor has large value, then neutral current has large value of fault current and it is made a damage to the utility. In order to analyze the grounding impedance characteristic, EMTP simulation has been used. The grounding impedance characteristic has been analyzed and tested for various grounding arrangements and electrode circuit shapes.

  • PDF

The Analysis of The Transport Current Property Depend on The Fault Angle of BSCCO HTS Cable (초전도 케이블용 BSCCO의 사고각에 따른 통전특성 분석)

  • Lee, Dong-Hyeok;Du, Ho-Ik;Doo, Seung-Gyu;Kim, Min-Ju;Kim, Yong-Jin;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.367-368
    • /
    • 2009
  • BSCCO HTS(High Temperature Superconductor) could be applied to superconducting cable, magnet and motor, using its hight critical properties. Especially, superconducting cable has a hight possibility of practical use due to the possibility of low voltage and high capacity transmission caused by its lower power loss than copper cable. In this paper, the transport characteristics of BSCCO superconducting cable, according to the change of BSCCO superconducting cable's accident point at phase $0^{\circ}$ and $45^{\circ}C$, were analyzed and compared each other. Consequently, when the accident was occur the resistance of the HTS was higher at the point phase $0^{\circ}$ than $45^{\circ}$ which means it will cause much higher load on the HTS.

  • PDF

Design of a Cascaded H-Bridge Multilevel Inverter Based on Power Electronics Building Blocks and Control for High Performance

  • Park, Young-Min;Ryu, Han-Seong;Lee, Hyun-Won;Jung, Myung-Gil;Lee, Se-Hyun
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.262-269
    • /
    • 2010
  • This paper proposes a practical design for a Cascaded H-Bridge Multilevel (CHBM) inverter based on Power Electronics Building Blocks (PEBB) and high performance control to improve current control and increase fault tolerance. It is shown that the expansion and modularization characteristics of the CHBM inverter are improved since the individual inverter modules operate more independently, when using the PEBB concept. It is also shown that the performance of current control can be improved with voltage delay compensation and the fault tolerance can be increased by using unbalance three-phase control. The proposed design and control methods are described in detail and the validity of the proposed system is verified experimentally in various industrial fields.