• Title/Summary/Keyword: fault activation

Search Result 32, Processing Time 0.027 seconds

Reactivated Timings of the Yangsan Fault in the Yeonghae area based on the Mineralogical Characteristics of Fault Clays (단층암 점토광물 특성에 기초한 영해지역 양산단층의 단층활동연대 결정)

  • Hong, Seongsik;Sim, Ho;Choi, Sung-Ja;Song, Yungoo
    • Economic and Environmental Geology
    • /
    • v.53 no.6
    • /
    • pp.645-654
    • /
    • 2020
  • We present the K-Ar age dating results of <0.1㎛ fraction of the selected fault rocks from the Yangsan fault in the Yeonghae area. Based on the mineralogical characterization, the <0.1㎛ fractions were mostly composed of 1Md illite polytype, or I-S interstratified mineral, which should be formed by fault activation. Therefore, we determined the timings of fault activation events by analyzing K-Ar age-dating for the <0.1㎛ fractions. Accordingly, the activation timings of Yangsan Fault in the Yeonghae area were determined as 45.5±1.1 Ma, 50.9±1.2 Ma, 58.2±1.3 Ma, 60.8±1.4 Ma, 65.3±1.6 Ma, 66.8±1.5 Ma, 67.1±1.5 Ma, and 75.1±1.7 Ma. These results indicate that at least 5-times of major fault events occurred in the Yangsan fault from late Mesozoic to Cenozoic Era. In the outcrop, age dating results tend to be younger age from the location of the oldest sample(75.1±1.7 Ma) toward to the both sides. From the results, it suggests that the fault activation extends from the location of oldest age saple to both sides. This geochronological research of the multiple fault activation ages for the Yangsan Fault will provide crucial information for establishing the tectonic evolution model in the southeastern part of the Korean Peninsula.

K-Ar Age-dating Results of Some Major Faults in the Gyeongsang Basin: Spatio-temporal Variability of Fault Activations during the Cenozoic Era (경상분지 내 주요단층의 K-Ar 연대: 신생대 단층활동의 시·공간적 특성)

  • Song, Yungoo;Sim, Ho;Hong, Seongsik;Son, Moon
    • Economic and Environmental Geology
    • /
    • v.52 no.5
    • /
    • pp.449-457
    • /
    • 2019
  • We present the K-Ar age-dating results of the bulk and the less than $0.1{\mu}m$ fraction of the fault gouges collected from some major faults in the Gyeongsang basin. We try to determine the timings of fault activation based on the mineralogical characteristics, and to interpret the spatio-temporal variability of the major fault events during the Cenozoic Era by considering together with the previous results. We propose at least the 3-times of major fault events at about 50 Ma, and just after 30 Ma and 20 Ma in the Gyeongsang basin, which were inferred from the combined approach of the K-Ar ages and the clay mineralogy of the bulk fault gouges and the <$0.1{\mu}m$ fractions. The fault activation timings of the Yangsan fault tend to be younger in the northern part than in the southern part. In particular, the inferred fault events just after 30 Ma and 20 Ma are mainly detected in the Ocheon fault and the related faults, and the fault in the Gyeongju area. The fault activation timings of the major faults can be revised accurately by using illite-age-analysis(IAA) method. These geochronological determinations of the multiple events of the major faults in the Gyeongsang basin are crucial to establish the tectonic evolution in the southeastern part of the Korean Peninsula during the Cenozoic Era.

Experimental research on the effect of water-rock interaction in filling media of fault structure

  • Faxu, Dong;Zhang, Peng;Sun, Wenbin;Zhou, Shaoliang;Kong, Lingjun
    • Geomechanics and Engineering
    • /
    • v.24 no.5
    • /
    • pp.471-478
    • /
    • 2021
  • Water damage is one of the five disasters that affect the safety of coal mine production. The erosion of rocks by water is a very important link in the process of water inrush induced by fault activation. Through the observation and experiment of fault filling samples, according to the existing rock classification standards, fault sediments are divided into breccia, dynamic metamorphic schist and mudstone. Similar materials are developed with the characteristics of particle size distribution, cementation strength and water rationality, and then relevant tests and analyses are carried out. The experimental results show that the water-rock interaction mainly reduces the compressive strength, mechanical strength, cohesion and friction Angle of similar materials, and cracks or deformations are easy to occur under uniaxial load, which may be an important process of water inrush induced by fault activation. Mechanical experiment of similar material specimen can not only save time and cost of large scale experiment, but also master the direction and method of the experiment. The research provides a new idea for the failure process of rock structure in fault activation water inrush.

Extraction of Lineament and Its Relationship with Fault Activation in the Gaeum Fault System (가음단층계의 선형구조 추출과 선형구조와 단층활동의 관련성)

  • Oh, Jeong-Sik
    • Journal of The Geomorphological Association of Korea
    • /
    • v.26 no.2
    • /
    • pp.69-84
    • /
    • 2019
  • The purpose of this study is to extract lineaments in the southeastern part of the Gaeum Fault System, and to understand their characteristics and a relationship between them and fault activation. The lineaments were extracted using a multi-layered analysis based on a digital elevation model (5 m resolution), aerial photos, and satellite images. First-grade lineaments inferred as an high-activity along them were classified based on the displacement of the Quaternary deposits and the distribution of fault-related landforms. The results of classifying the first-grade lineaments were verified by fieldwork and electrical resistivity survey. In the study area of 510 km2, a total of 222 lineaments was identified, and their total length was 333.4 km. Six grade lineaments were identified, and their total length was 11.2 km. The lineaments showed high-density distribution in the region along the Geumcheon, Gaeum, Ubo fault, and a boundary of the Hwasan cauldron consisting the Gaeum Fault System. They generally have WNW-ESE trend, which is the same direction with the strike of Gaeum Fault System. Electrical resistivity survey was conducted on eight survey lines crossing the first-grade lineament. A low-resistivity zone, which is assumed to be a fault damage zone, has been identified across almost all survey lines (except for only one survey line). The visual (naked eyes) detecting of the lineament was evaluated to be less objectivity than the automatic extraction using the algorithm. However, the results of electrical resistivity survey showed that first-grade lineament extracted by visual detecting was 83% reliable for inferred fault detection. These results showed that objective visual detection results can be derived from multi-layered analysis based on tectonic geomorphology.

An Improved Short Circuit Protection Scheme for IGBT Inverters (IGBT 인버터를 위한 향상된 단락회로 보호기법)

  • 서범석;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.426-436
    • /
    • 1998
  • Identification of fault current during the operation of a power semiconductor switch and activation of suitable remedial actions are important for reliable operation of power converters. A short circuit is a basic and severe fault situation in a circuit structure such as voltage source converters. This paper presents a new active protection circuit for fast and precise clamping and safe shutdown of fault currents of the IGBTs. This circuit allows operation of the IGBTs with a higher on-state gate voltage, which can thereby reduce the conduction loss in the device without compromising the short circuit protection characteristics. The operation of the circuit is studied under various conditions, considering variation of temperature, rising rate of fault current, gate voltage value, and protection circuit parameters. An evaluation of the operation of the circuit is made using IGBTs from different to confirm the effectiveness of the protection circuit.

  • PDF

Behavior of cable-stayed bridges built over faults

  • Raftoyiannis, I.G.;Michaltsos, G.T.;Konstantakopoulos, T.G.
    • Interaction and multiscale mechanics
    • /
    • v.5 no.3
    • /
    • pp.187-210
    • /
    • 2012
  • Cable-stayed bridges are commonly used in modern bridge engineering for covering long spans. In some special cases, the designer is obliged to build such a bridge over an existing fault. Activation of this fault is possible to bring about a relative displacement or separation movement between two neighboring pylons of the bridge built on opposite sides of the fault. In this work, the effect of such a fault-induced pylon displacement on bridge's deformations and on cables' strength is thoroughly studied for several types of cable-stayed bridges and useful conclusions are drawn aiming the design. The influence of a possible earthquake and traffic loads crossing the bridge when the pylons are moving away from each other is not examined.

CONTROL PHILOSOPHY AND ROBUSTNESS OF ELECTRONIC STABILITY PROGRAM FOR THE ENHANCEMENT OF VEHICLE STABILITY

  • Kim, D.S.;Hwang, I.Y.
    • International Journal of Automotive Technology
    • /
    • v.7 no.2
    • /
    • pp.201-208
    • /
    • 2006
  • This paper describes the control philosophy of ESP(Electronic Stability Program) which consists of the stability control the fault diagnosis and the fault tolerant control. Besides the functional performance of the stability control, robustness of control and fault diagnosis is focused to avoid the unnecessary activation of the controller. The look-up tables are mentioned to have the accurate target yaw rate of the vehicle and obtained from vehicle tests for the whole operation range of the steering wheel angle and the vehicle speed. The wheel slip control with a design goal of wheel slip invariance is implemented for the yaw compensation and the target wheel slip is determined by difference between the target yaw rate and actual yaw rate. Since the ESP has a high severity level and the robust control is required, the robustness margin for the stability control is determined according to several uncertainties and the robust fault diagnosis is performed. Both computer simulation and test results are shown in this paper.

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.

A Study on the High Temperature Deformation Behavior of a Solid Solution Aluminium Alloy (알루미늄 고용체 합금의 고온변형 거동에 관한 연구)

  • Kim, Ho-Gyeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.346-351
    • /
    • 1997
  • The creep characteristics of an Al-5wt.% Ag alloy including the stress exponent, the activation energy for creep and the shape of the creep curve were investigated at a normalized shear stress extending from $ 10^{-5}{\;}to{\;}3{\times}10^{-4}$ and in the temperature range of 640-873 K, where silver is in solid solution. The experimental results shows that the stress exponent is 4.6, the activation energy is 141 kJ/mole, and the stacking fault energy is $180{\;}mJ/m^2$, suggesting that the creep behavior of Al-5 wt.% Ag is similiar to that reported for pure aluminum, and that under the current experimental conditions, the alloy behaves as a class II(metal class). The above creep characteristics obtained for Al-5 wt.% Ag are discussed in the light of prediction regarding deformation mechanisms in solid solution alloys.

Reactivated Timings of Yangsan Fault in the Sangcheon-ri Area, Korea (상천리 일대 양산단층의 재활동 연대)

  • Song, Yungoo;Park, Changyun;Sim, Ho;Choi, Woohyun;Son, Moon;Khulganakhuu, Chuluunbaatar
    • Economic and Environmental Geology
    • /
    • v.49 no.2
    • /
    • pp.97-104
    • /
    • 2016
  • Here we firstly present that a timing of reactivated event of Yangsan fault, the major fault in the southeastern Korean Peninsula, by using combined approaches of the optimized illite-polytype quantification, the K-Ar age-dating, and the recently developed illite-age-analysis (IAA) approach for the fault clays from Sangcheon-ri area of Yangsan main fault line. Two chronological record of brittle fault-activation event at about 41.5~43.5 and 50.7 Ma were determined from 3 fault gouges suggesting a crucial reactivation time-scheme. Furthermore, the regional processes that drive tectonics to form and reactivate the Yangsan fault may be explained from the chronological analysis for additional sites along the Yangsan fault.