• Title/Summary/Keyword: fast response time

Search Result 839, Processing Time 0.032 seconds

Energy Keys Based Scalable Indexing Schemes of Large Color Image Archives (에너지 키에 기초한 대형 칼라 영상 기록물의 계층적 인덱싱 기법)

  • 박대철;강종묵
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.225-228
    • /
    • 2001
  • We propose a method which has effective scalable indexing characteristics of large color image archives. Color key and energy key method which uses provides high performance of fast accessing and has almost constant query response time over DH size.

  • PDF

A Study on the Prevention System of Mixed Assembly Under the Part of Supply Chain Management using Uncommon BOM (SCM에서의 효율적인 혼입방지시스템에 대한 연구)

  • 강민식;김재련
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.24 no.69
    • /
    • pp.13-22
    • /
    • 2001
  • The efficient quality assurance system to prevent mixed assembly in introduced in this paper, It supports JIT(Just-In-Time) based Kanban and demand pull system. A new system is designed for the synchronized production and quality assurance using barcode and production kanban card, And the performance improvement method for the stable and fast response of the proposed system is suggested in this paper also. As the result of the proposed system, we improved production status visibility and quality traceability.

  • PDF

Nano-sized Polymer-dispersed Liquid Crystal with Strong Scattering Intensity Made by Emulsification Process

  • Jin, Yan;Lee, Burm-Young;Kwon, Soon-Bum;Lee, Ji-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.655-656
    • /
    • 2009
  • Here we report a nano-sized polymer-dispersed liquid crystal (NPDLC) with an excellent scattering effect due to the maximized Mie scattering. We used a modified emulsification method combined with a limited coalescence mechanism. The fabrication process is simpler to obtain uniform nano-sized droplets rather than the conventional polymerizationinduced phase separation method.

  • PDF

FET type Urea Sensor (FET형 요소 감지 소자)

  • Moon, Byung-Joon;Lee, Jong-Hyun;Sohn, Byung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.490-492
    • /
    • 1987
  • Urea-Sensor was fabricated by immobilizing urease on ISFET's gate using BSA(bovine serum albumin) and glutaraldehyde, and its characteristics were examined. This sensor showed approximately linear characteristic in the urea concentration range of $3{\times}10^{-5}-10^{-9}$ (g/ml). Fast response time was obtained and minute amounts of expensive enzyme were used in comparison to general electrode type biosensors.

  • PDF

Advanced Pressure Control of Piezoelectric Valve on Electro-hydraulic Braking (피에조밸브를 적용한 전자유압브레이크의 압력제어)

  • DocKo, Jong-Hun;Park, Gwi-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1576-1577
    • /
    • 2007
  • As a intelligent valve piezoelectric valve is to applied to various fields of application. Piezoelectric valves have fast response time and good linearity for pressure control but its hysteresis displacement by its stack actuator influences on pressure control in electro-hydraulic braking. Solenoid valves are traditional element to control hydraulic pressure but this paper proposes piezoelectric valve for brake pressure control with hysteresis compensation.

  • PDF

Early Gastrin Response to Single Glucose and Casein Feeding (포도당 및 Casein 액 단일투여에 의한 조기 Gastrin 반응)

  • Sung, Ho-Kyung;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.15 no.2
    • /
    • pp.97-101
    • /
    • 1981
  • The early plasma gastrin responses to single oral glucose or casein solution were studied in the same normal subjects on different days. After an overnight fast, glucose or casein solution was ingested within few minutes at the breakfast time. The plasma gastrin responses to these solutions were compared and contrasted with the concentration when the subjects received glucose solution intravenously. Results were as follows: 1) Rapid intravenous glucose infusion did not produce any changes in the plasma gastrin concentration. 2) Plasma gastrin concentration rose and peaked within 10 minutes after an oral liquid ingestion and then decreased substantially by 15 minutes, but remained slightly above fasting levels at 60 minutes. 3) There was no significant difference between the mean plasma gastrin concentrations after glucose of casein ingestion, but each fluid produced a significant increase in serum gastrin above fasting levels. 4) The subjects who produced high plasma gastrin response to glucose solution did so to casein solution. Conversely a low response to one solution reflected a low response to the other solution. 5) From the above results, authors discussed that individual responsibility rather than the sorts of meals is the factor in the determination of the magnitude of the early gastrin response.

  • PDF

A Real-time Eye Tracking Algorithm for Autostereoscopic 3-Dimensional Monitor (무안경식 3차원 모니터용 실시간 눈 추적 알고리즘)

  • Lim, Young-Shin;Kim, Joon-Seek;Joo, Hyo-Nam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.8
    • /
    • pp.839-844
    • /
    • 2009
  • In this paper, a real-time eye tracking method using fast face detection is proposed. Most of the current eye tracking systems have operational limitations due to sensors, complicated backgrounds, and uneven lighting condition. It also suffers from slow response time which is not proper for a real-time application. The tracking performance is low under complicated background and uneven lighting condition. The proposed algorithm detects face region from acquired image using elliptic Hough transform followed by eye detection within the detected face region using Haar-like features. In order to reduce the computation time in tracking eyes, the algorithm predicts next frame search region from the information obtained in the current frame. Experiments through simulation show good performance of the proposed method under various environments.

The effects of short persistent CCFL in Blinking Back Light Unit to reduce blur on TFT-LCD

  • Han, J.M.;Bae, K.W.;Kim, S.Y.;Kim, Y.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.694-697
    • /
    • 2003
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by adjusting between on time and off time for video signal input during 1 frame (16.7ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by blinking drive. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

  • PDF

An experimental study on the concentration distribution of helium and air mixture in the direct injection type engine (헬륨$\cdot$공기흡합기농도분포에 관한 실험적 연구)

  • 김봉곤;하종률;권순석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.33-39
    • /
    • 1990
  • This study has been conducted by experiments for distribution of concentration of helium gas, which is jetted into stationary atmosphere at the normal temperature and pressure. It is able to obtain the data for concentration of helium and air mixtures by the use of hot wire probe which has fast response. At an up stream, the concentration gradient which is attained is steep. At a down stream, the mixing time of helium and air is gradually shortened with the lapse of time in front of a jet. The arrival frequency of a jet in an unsteady area is mostly constant from 0% to 100% up to 80mm, but the time which is reaching to 100% is gradually to lengthen as a descending downstream. After starting a jet and the point of 90%, the mixing time is especially to lengthen. This reason comes from the turbulent intensity which causes for mixing of helium and air. This time difference which causes according to lengthen a jet should be considered in the design of combustion chamber.

  • PDF

Precise Position Control of a Linear Stage with I/Q heterodyne Interferometer Feedback

  • Moon, Chan-Woo;Lee, Sung-Ho;Chung, J.K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1142-1146
    • /
    • 2004
  • The ultra precision linear stage is an essential device in the fields of MEMS and Bio technology. A piezo electric motor is widely used for its better linear characteristics, faster response time, and smaller size than conventional electro-magnetic actuator. We develop a new inchworm type motor to implement an actuator-integrated a long stroke linear stage which can move fast. To implement a servo system, we use a heterodyne interferometer as a position sensor, and we propose a new measurement technique using I/Q demodulator, and we propose a counting method to measure the position of fast moving object with low cost circuitry. The characteristics of the actuator and servo system are evaluated by measuring its displacement with a commercial laser interferometer.

  • PDF