• 제목/요약/키워드: fan

검색결과 3,597건 처리시간 0.03초

전산유체역학을 활용한 가전 제품용 원심팬 블레이드의 단계별 형상 최적화 (MULTI STAGE SHAPE OPTIMIZATION OF CENTRIFUGAL FAN FOR HOME APPLIANCE USING CFD)

  • 김종수;강태곤
    • 한국전산유체공학회지
    • /
    • 제21권3호
    • /
    • pp.39-47
    • /
    • 2016
  • We conducted a multi-stage optimization to secure the desired performance of a centrifugal fan for home appliance in an early stage of product development. In optimization, the static pressure at the outlet of the fan is chosen as an objective function that is to be maximized, providing the required flow rate at the operating point of the fan. The optimization procedure begins with parameters for an initial baseline fan design. The baseline design is optimized by using a commercial optimization package. Accordingly, the corresponding blade models with a set of geometrical parameters are generated. Flow through a fan is simulated by solving the Reynolds-averaged Navier-Stokes equations. A multi-stage optimization scheme is employed to determine the family of optimum values for the parameters, leading to the pressure increase at the outlet of the fan. To validate the numerically obtained optimal design parameters, we fabricated the three types of fans using rapid prototyping and assessed the performance using a fan tester. Experimental results show that the design parameters at each stage satisfy the goal of optimization. The multi-stage optimization process turned out to be a useful tool in the development of a centrifugal fan.

와류 저감을 통한 냉장고 냉기순환용 고성능/저소음 원심홴의 개발 (Development of High-performance/low-noise Centrifugal Fan Circulating Cold Air Inside a Household Refrigerator by Reduction of Vortex Flow)

  • 신동휘;유서윤;정철웅;김태훈;정지원
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.428-435
    • /
    • 2016
  • In this paper, high-performance and low-noise centrifugal fan used to circulate cold air inside a household refrigerator is developed by reducing the vortex flow observed near the tip of fan hub. First, the performance of the existing centrifugal fan is investigated through the experiment using a fan tester and the characteristics of detailed flow field obtained from the CFD simulation are closely examined. The strong vortex flow is observed in the vicinity of the tip of fan hub. Based on this result, new design is devised to reduce this vortex flow. As a result, it is numerically and experimentaly found that the volume flow rate of the new fan increases and the radiated noise decreases in comparison with the existing fan at the same rotation speed.

Jet fan 근접 화재 발생 시 제연 특성 연구 (Study of the Smoke Control Characteristics for Fire Near Jet Fans)

  • 김종윤;서태범;임경범;유지오;이동호
    • 한국화재소방학회논문지
    • /
    • 제21권1호
    • /
    • pp.82-89
    • /
    • 2007
  • 본 연구에서는 Jet fan 근접 거리에서 화재 발생 시 최소거리의 Jet fan을 이용하여 연기를 제어하기 위하여 PIV에 의한 가시화실험을 실시하였고, 또한 실험을 통해 얻어진 결과와 FDS 수치해석 그 결과를 비교, 분석 하였다. 터널 내 화재발생 시 Jet fan 설치에 따른 효율적인 연기제어 방식의 정량적 데이터 분석 결과 근접 Jet fan의 작동은 화원과 25m 이상의 거리에서만 가동해야 한다. 또한 Jet fan과 화원의 이격거리가 50m 부근에서 가장 안정적으로 연기가 제어되며 75m 이상의 거리에서는 터널 중앙 부근에서 과풍속 경향이 나타나며 제연되었다.

석유 홴 히터의 난방 능력 고찰 (Investigation of Heating Performance of Kerosene Fan Heater)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제1권1호
    • /
    • pp.51-60
    • /
    • 1997
  • In this paper, we investigated the heating performance and the basic characteristics required for normal combustion of kerosene fan heater. And also the iso-velocity contours and the iso-temperature contours of hot gas discharged from the exit of kerosene fan heater were analyzed. The experiment was carried out with kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of $240mm{\times}240mm{\times}1200mm$. The purpose of this paper was to obtain the basic data for new design from conventional kerosene fan heater. Consequently it was found that (i) the pressure ratio $P_2/P_1$ had a comparatively constant value of 0.844 according to the increase of the revolution of turbo fan, (ii) the primary excess air ratio had a range of $0.84{\sim}1.11$ during normal combustion, and (iii) the heating performance of kerosene fan heater had a range of $1,494{\sim}3,852kcal/hr$.

  • PDF

자동차용 냉각팬의 불량검출을 위한 팬 밸런서 시스템 개발 (Development of Fan Balancer System for Detecting Unbalance of Automobile Cooling Fan)

  • 김성호;육의수
    • 한국지능시스템학회논문지
    • /
    • 제19권1호
    • /
    • pp.83-89
    • /
    • 2009
  • 일반적으로 자동차용 냉각팬은 차랑 냉각기의 온도를 낮추기 위해 사용되고 있다. 자동차용 냉각팬은 플라스틱 사출 공정에 의해 제작되며 사출시 사용되는 모재의 불균일성으로 인해 냉각팬 날개의 무게 중심이 중심에서 벗어나는 경우가 발생하게 된다. 이러한 불균형은 자동차 소음의 주된 원인이 되기 때문에 이에 대한 검사는 필수적으로 요구된다. 이에 본 연구에서는 로드셀을 이용한 냉각팬 회전날개에서 발생되는 불균형의 위치 및 크기를 효율적으로 검출할 수 있는 팬 밸런서 시스템을 제안하고 제안된 시스템의 불평형 검출 성능 확인을 위해 실제 적용 실험을 수행하였다.

엇회전식 축류 펜의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Flow Fan)

  • 최진용;조이상;조진수;원유필
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.201-210
    • /
    • 2002
  • Experiments were done for performance and flow characteristics of a counter-rotating axial flow fan. Performance curves of a counter-rotating axial flow fan were obtained and compared by varying the blade pitch angles. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe and a slanted hot-wire. The velocity profiles between the hub and tip of the fans were measured and analyzed at the peak efficiency point. The peak efficiency of the counter-rotating axial flow fan was improved about 15% respectively, compared with the single rotating axial fan. The single rotating axial flow fan showed relatively law efficiency due to the swirl velocities behind rotor exit which produced pressure losses. The counter-rotating axial flow fan showed that the swirl velocity generated by the front rotor was eliminated by the rear rotor and the associated dynamic pressure is recovered in the from of the static pressure rise.

태양에너지를 이용한 곡물건조시스템의 시뮬레이션에 관한 연구 (Simulation of Drying Grain with Solar-Heated Air)

  • 금동혁;김용운
    • Journal of Biosystems Engineering
    • /
    • 제4권2호
    • /
    • pp.65-83
    • /
    • 1979
  • Low-temperature drying systems have been extensively used for drying cereal grain such as shelled corn and wheat. Since the 1973 energy crisis, many researches have been conducted to apply solar energy as supplemental heat to natural air drying systems. However, little research on rough rice drying has been done in this area, especially very little in Korea. In designing a solar drying system, quality loss, airflow requirements, temperature rise of drying air, fan power and energy requirements should be throughly studied. The factors affecting solar drying systems are airflow rate, initial moisture content, the amount of heat added to drying air, fan operation method and the weather conditions. The major objectives of this study were to analyze the effects of the performance factors and determine design parameters such as airflow requirements, optimum bed depth, optimum temperature rise of drying air, fan operation method and collector size. Three hourly observations based on the 4-year weather data in Chuncheon area were used to simulate rough rice drying. The results can be summarized as follows: 1. The results of the statistical analysis indicated that the experimental and predicted values of the temperature rise of the air passing through the collector agreed well. 2. Equilibrium moisture content was affected a little by airflow rate, but affected mainly by the amount of heat added, to drying air. Equilibrium moisture content ranged from 12.2 to 13.2 percent wet basis for the continuous fan operation, from 10.4 to 11.7 percent wet basis for the intermittent fan operation respectively, in range of 1. 6 to 5. 9 degrees Centigrade average temperature rise of drying air. 3. Average moisture content when top layer was dried to 15 percent wet basis ranged from 13.1 to 13.9 percent wet basis for the continuous fan operation, from 11.9 to 13.4 percent wet basis for the intermittent fan operation respectively, in the range of 1.6 to 5.9 degrees Centigrade average temperature rise of drying air and 18 to 24 percent wet basis initial moisture content. The results indicated that grain was overdried with the intermittent fan operation in any range of temperature rise of drying air. Therefore, the continuous fan operation is usually more effective than the intermittent fan operation considering the overdrying. 4. For the continuous fan operation, the average temperature rise of drying air may be limited to 2.2 to 3. 3 degrees Centigrade considering safe storage moisture level of 13.5 to 14 perceut wet basis. 5. Required drying time decrease ranged from 40 to 50 percent each time the airflow rate was doubled and from 3.9 to 4.3 percent approximately for each one degrees Centigrade in average temperature rise of drying air regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on required drying time. 6. Required drying time increase ranged from 18 to 30 percent approximately for each 2 percent increase in initial moisture content regardless of the fan operation methods, in the range of 18 to 24 percent moisture. 7. The intermittent fan operation showed about 36 to 42 percent decrease in required drying time as compared with the continuous fan operation. 8. Drymatter loss decrease ranged from 34 to 46 percent each time the airflow rate was doubled and from 2 to 3 percent approximately for each one degrees Centigrade in average temperature rise of drying air, regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on drymatter loss. 9. Drymatter loss increase ranged from 50 to 78 percent approximately for each 2 percent increase in initial moisture content, in the range of 18 to 24 percent moisture. 10. The intermittent fan operation: showed about 40 to 50 percent increase in drymatter loss as compared with the continuous fan operation and the increasing rate was higher at high level of initial moisture and average temperature rise. 11. Year-to-year weather conditions had a little effect on required drying time and drymatter loss. 12. The equations for estimating time required to dry top layer to 16 and 1536 wet basis and drymatter loss were derived as functions of the performance factors. by the least square method. 13. Minimum airflow rates based on 0.5 percent drymatter loss were estimated. Minimum airflow rates for the intermittent fan operation were approximately 1.5 to 1.8 times as much as compared with the continuous fan operation, but a few differences among year-to-year. 14. Required fan horsepower and energy for the intermittent fan operation were 3. 7 and 1. 5 times respectively as much as compared with the continuous fan operation. 15. The continuous fan operation may be more effective than the intermittent fan operation considering overdrying, fan horsepower requirements, and energy use. 16. A method for estimating the required collection area of flat-plate solar collector using average temperature rise and airflow rate was presented.

  • PDF

태양에너지를 이용한 곡물건조시스템의 시뮬레이션에 관한 연구 (Simulation of Drying Grain with Solar-Heated Air)

  • 금동혁
    • Journal of Biosystems Engineering
    • /
    • 제4권2호
    • /
    • pp.64-64
    • /
    • 1979
  • Low-temperature drying systems have been extensively used for drying cereal grain such as shelled corn and wheat. Since the 1973 energy crisis, many researches have been conducted to apply solar energy as supplemental heat to natural air drying systems. However, little research on rough rice drying has been done in this area, especially very little in Korea. In designing a solar drying system, quality loss, airflow requirements, temperature rise of drying air, fan power and energy requirements should be throughly studied. The factors affecting solar drying systems are airflow rate, initial moisture content, the amount of heat added to drying air, fan operation method and the weather conditions. The major objectives of this study were to analyze the effects of the performance factors and determine design parameters such as airflow requirements, optimum bed depth, optimum temperature rise of drying air, fan operation method and collector size. Three hourly observations based on the 4-year weather data in Chuncheon area were used to simulate rough rice drying. The results can be summarized as follows: 1. The results of the statistical analysis indicated that the experimental and predicted values of the temperature rise of the air passing through the collector agreed well.2. Equilibrium moisture content was affected a little by airflow rate, but affected mainly by the amount of heat added, to drying air. Equilibrium moisture content ranged from 12.2 to 13.2 percent wet basis for the continuous fan operation, from 10.4 to 11.7 percent wet basis for the intermittent fan operation respectively, in range of 1. 6 to 5. 9 degrees Centigrade average temperature rise of drying air.3. Average moisture content when top layer was dried to 15 percent wet basis ranged from 13.1 to 13.9 percent wet basis for the continuous fan operation, from 11.9 to 13.4 percent wet basis for the intermittent fan operation respectively, in the range of 1.6 to 5.9 degrees Centigrade average temperature rise of drying air and 18 to 24 percent wet basis initial moisture content. The results indicated that grain was overdried with the intermittent fan operation in any range of temperature rise of drying air. Therefore, the continuous fan operation is usually more effective than the intermittent fan operation considering the overdrying.4. For the continuous fan operation, the average temperature rise of drying air may be limited to 2.2 to 3. 3 degrees Centigrade considering safe storage moisture level of 13.5 to 14 perceut wet basis.5. Required drying time decrease ranged from 40 to 50 percent each time the airflow rate was doubled and from 3.9 to 4.3 percent approximately for each one degrees Centigrade in average temperature rise of drying air regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on required drying time.6. Required drying time increase ranged from 18 to 30 percent approximately for each 2 percent increase in initial moisture content regardless of the fan operation methods, in the range of 18 to 24 percent moisture.7. The intermittent fan operation showed about 36 to 42 percent decrease in required drying time as compared with the continuous fan operation.8. Drymatter loss decrease ranged from 34 to 46 percent each time the airflow rate was doubled and from 2 to 3 percent approximately for each one degrees Centigrade in average temperature rise of drying air, regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on drymatter loss. 9. Drymatter loss increase ranged from 50 to 78 percent approximately for each 2 percent increase in initial moisture content, in the range of 18 to 24 percent moisture. 10. The intermittent fan operation: showed about 40 to 50 percent increase in drymatter loss as compared with the continuous fan operation and the increasing rate was higher at high level of initial moisture and average temperature rise.11. Year-to-year weather conditions had a little effect on required drying time and drymatter loss.12. The equations for estimating time required to dry top layer to 16 and 1536 wet basis and drymatter loss were derived as functions of the performance factors. by the least square method.13. Minimum airflow rates based on 0.5 percent drymatter loss were estimated.Minimum airflow rates for the intermittent fan operation were approximately 1.5 to 1.8 times as much as compared with the continuous fan operation, but a few differences among year-to-year.14. Required fan horsepower and energy for the intermittent fan operation were3. 7 and 1. 5 times respectively as much as compared with the continuous fan operation.15. The continuous fan operation may be more effective than the intermittent fan operation considering overdrying, fan horsepower requirements, and energy use.16. A method for estimating the required collection area of flat-plate solar collector using average temperature rise and airflow rate was presented.

분산제어 설비를 이용한 Fan Stall Warning System 설계(I) (Fan Stall Warning System Design Using the DCS Logic(I))

  • 노용기;조현섭;장성환
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2006년도 춘계학술발표논문집
    • /
    • pp.236-239
    • /
    • 2006
  • 500MW급 대용량 보일러 통풍계통의 Fan Stall 감시 장치는 Fan 이상 발생시 Fan을 보호하기 위하여 정지시키는 기능을 한다. 그러나 Fan Stall 감시 장치의 빈번한 고장으로 신뢰성이 저하되고 운전에 영향을 미치므로 이것을 DCS Logic으로 구성하여 신뢰성을 향상시켰다.

  • PDF

프로펠라 팬과 앞판과의 간격이 팬 성능에 미치는 영향에 관한 연구 (The Study on Performance of Propeller Fan according to Distance of Front Plate)

  • 엄윤섭;부정숙;윤인철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.494-501
    • /
    • 2000
  • A study on performance of a propeller fan according to the distance between the front plate and the fan was conducted experimentally. Different characteristics of performance were found on the performance curve. Flow measurements using the three dimensional LDV system show that the zone of recirculation exists around the fan. The differences of performance in changes of the distance occurs because the zone of recirculation is much wider at the distance of 24mm than at that of 30mm.

  • PDF