• Title/Summary/Keyword: failure patterns

Search Result 600, Processing Time 0.029 seconds

Result of Radiation Therapy of Sino-nasal Cancers Using Partial Attenuation Filter (투과성 필터를 이용하여 방사선 치료를 받은 부비동 및 비암의 치료 결과)

  • Kim, Jin-Hee;Kim, Ok-Bae;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.118-124
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: This study was to evaluate the survival and pattern of failure after radiation therapy of sino-nasal cancer using partial attenuation filer and wedged beams and to help radiotherapy planning of sino-nasal cancer. $\underline{Materials\;and\;Methods}$: Between February 1992 and March 2003, 17 patients with sino-nasal cancers underwent radiation therapy using partial attenuation filter at Dongsan Medical Center, Keimyung university. There were 9 male and 8 female patients. Patients' age ranged from 40 to 75 years (median 59 years). There were 10 patients of maxillary sinus cancer, 7 patiens of nasal cancer. The histologic type was squamous cell carcinoma in 11, adenoid cystic carcinoma in 4 and olfactory neuroblastoma in 2. The distribution of clinical stage by the AJCC system was 3 for stage II, 7 for III and 6 for IV. The five patients were treated with radiation alone and 12 patients were treated with surgery and postoperative radiation therapy. The range of total radiation dose delivered to the primary tumor was from 44 to 76 Gy (median 60 Gy). The follow-up period ranged from 3 to 173 months with median of 78 months. $\underline{Results}$: The overall 2 year survival rate and disease free survival rate was 76.4%. The 5 year and 10 year survival rate were 76.4% and 45.6% and the 5 year and 10 year disease free survival rate was 70.6%. The 5 year disease free survival rate by treatment modality was 91.6% for postoperative radiation group and 20% for radiation alone group, statistical significance was found by treatment modality (p=0.006). There were no differences in survival by pathology and stage. There were local failure in 5 patients (29%) but no distant failure and no severe complication required surgical intervention. $\underline{Conclusion}$: Radiation therapy of sino-nasal cancer using partial attenuation filter was safe and effective. Combined modality with conservative surgery and radiation therapy was more advisable to achieve loco-regional control in sino-nasal cancer. Also we considered high precision radiation therapy with dose escalation and development of multi-modality treatment to improve local control and survival rate in advanced sino-nasal cancer.

An Analysis of Prognostic Factors Affecting the Outcome of Radiation Therapy for Nasopharyngeal Carcinoma (비인강암의 방사선치료 곁과 및 생존율에 관한 예후인자 분석)

  • Jung, Young-Yeon;Kim, Ok-Bae;Kim, Jin-Hee
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.71-77
    • /
    • 2005
  • Purpose: This retrospective study was conduced to analyze the treatment results and to evaluate the prognostic factors affecting the survival of nasopharyngeal carcinoma patients. Materials and Methods: From 1987 to 2002, we analyzed 43 patients who had nasopharyngeal carcinomas that were histologically confirmed and who had also completed the planned radiation therapy course at Keimyung University Dongsan Medical Center According to the 6th edition of American Joint Committee on Cancer staging system, 12 patients ($27.9\%$) were at Stage 11, 13 ($30.2\%$) were at Stage III and 18 ($41.9\%$) were at Stage IV Histopathologically, there were 15 ($34.9\%$) squamous cell carcinomas, 8 ($18.5\%$) nonkeratinizing carcinomas, 17 ($39.5\%$) undifferentiated carcinomas, and 3 ($7.0\%$) lymphoepitheliomas. Among the total 43 patients, 31 patients ($72.1\%$) were treated with only radiation therapy. Neoadjuvant chemotherapy was peformed on 7 patients ($16.3\%$) and concurrent chemoradiotherapy was performed on S patients ($11.6\%$). Cisplatin and 5-Fluorouracil were administered to 11 patients for 4 cycles, and Cisplatin and Taxotere were administered to 1 patient for 6 cycles. The range of the total radiation dose delivered to the primary tumor was from 61.2 to 84 Gy (median 70.4 Gy), The follow-up period ranged from 2 to 197 months with median follow-up of 84 months. Results: The local control rate at 6 months after radiation therapy was $90.7\%$. The five year overall survival and disease free survival rates were $50.7\%$ and $48.9\%$, respectively. On the multivariate analysis, the age, T-stage ($T_{1-3}\;vs\;T_4$), N-stage and AJCC stage were the statistically significant prognostic factors affecting survival (p<0.05). The patterns of failure were as follows: local failure only in 3 patients ($7.0\%$), local and systemic failure in 1 patient ($2.3\%$), and distant metastasis only in 11 patients ($25.6\%$). Conclusion: The prognostic factors affecting the outcome of nasopharyngeal carcinoma were age, T-stage (7$T_{1-3}\;vs\;T_4$), N-stage and stage. Because systemic metastasis was the main failure pattern noted for nasopharyngeal carcinoma, systemic chemotherapy is needed to decrease the rate of distant metastasis for nasopharyngeal carcinoma. In audition, research for more effective chemotherapeutical regimens and schedules is also needed.

Fracture resistance of ceramic brackets to arch wire torsional force (토오크 양에 따른 세라믹 브라켓의 파절 저항성)

  • Han, Jung-Heum;Chang, Minn-Hii;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.293-304
    • /
    • 2007
  • The purpose of this study was to estimate the fracture resistance of commercially available ceramic brackets to torsional force exerted from arch wires and to evaluate the characteristics of bracket fracture. Methods: Lingual root torque was applied to maxillary central incisor brackets with 0.022-inch slots by means of a $022\;{\times}\;028-inch$ stainless steel arch wire. A custom designed apparatus that attached to an Instron was used to test seven types of ceramic brackets (n = 15). The torque value and torque angle at fracture were measured. In order to evaluate the characteristics of failure, fracture sites and the failure patterns of brackets were examined with a Scanning Electron Microscope. Results: Crystal structure and manufacturing process of ceramic brackets had a significant effect on fracture resistance. Monocrystalline alumina (Inspire) brackets showed significantly greater resistance to torsional force than polycrystalline alumina brackets except InVu. There was no significant difference in fracture resistance during arch wire torsional force between ceramic brackets with metal slots and those without metal slots (p > 0.05). All Clarity brackets partially fractured only at the incisal slot base and the others broke at various locations. Conclusion: The fracture resistance of all the ceramic brackets during arch wire torsion appears to be adequate for clinical use.

Three-Dimensional Limit Equilibrium Stability Analysis of the Irregularly Shaped Excavation Comer with Skew Soil Nailing System

  • Kim, Hong Taek;Par
    • Geotechnical Engineering
    • /
    • v.14 no.3
    • /
    • pp.73-94
    • /
    • 1998
  • In the present study, a method of the three-dimensional limit equilibrium stability analysis of shape of the potential failure wedge for the concave-shaped excavation corner is assumed on the basis of the results of the FLACSU program analysis. Estimation of the three-dimensional seepage forces expected to act on the failure wedge is made by solving the three-dimensional continuity equation of flow with appropriate boundary conditions. By using the proposed method of three-dimensional stability analysis of the concave-shaped excavation corner, a parametric study is performed to examine the reinforcement effect of skew soil nailing system, range of the efficient skew angles and seepage effect on the overall stability. Also examined is the effect of an existence of the right-angled excavation corner on three-dimensional deflection behaviors of the convex-shaped skew soil nailing walls. The results of analyses of the convexshaped excavation corner with skew soil nailing system is further included to illustrate the effects of various design parameters for typical patterns of skew nails reinforcement system.

  • PDF

Bond strength of veneer ceramic and zirconia cores with different surface modifications after microwave sintering

  • Saka, Muhammet;Yuzugullu, Bulem
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.485-493
    • /
    • 2013
  • PURPOSE. To evaluate the effects of surface treatments on shear bond strength (SBS) between microwave and conventionally sintered zirconia core/veneers. MATERIALS AND METHODS. 96 disc shaped Noritake Alliance zirconia specimens were fabricated using YenaDent CAM unit and were divided in 2 groups with respect to microwave or conventional methods (n=48/group). Surface roughness (Ra) evaluation was made with a profilometer on randomly selected microwave (n=10) and conventionally sintered (n=10) cores. Specimens were then assessed into 4 subgroups according to surface treatments applied (n=12/group). Groups for microwave (M) and conventionally (C) sintered core specimens were as follows; $M_C$,$C_C$: untreated (control group), $M_1,C_1:Al_2O_3$ sandblasting, $M_2,C_2$:liner, $M_3,C_3:Al_2O_3$ sandblasting followed by liner. Veneer ceramic was fired on zirconia cores and specimens were thermocycled (6000 cycles between $5^{\circ}-55^{\circ}C$). All specimens were subjected to SBS test using a universal testing machine at 0.5 mm/min, failure were evaluated under an optical microscope. Data were statistically analyzed using Shapiro Wilk, Levene, Post-hoc Tukey HSD and Student's t tests, Two-Way-Variance- Analysis and One-Way-Variance-Analysis (${\alpha}$=.05). RESULTS. Conventionally sintered specimens ($1.06{\pm}0.32{\mu}m$) showed rougher surfaces compared to microwave sintered ones ($0.76{\pm}0.32{\mu}m$)(P=.046), however, no correlation was found between SBS and surface roughness (r=-0.109, P=.658). The statistical comparison of the shear bond strengths of $C_3$ and $C_1$ group (P=.015); $C_C$ and $M_C$ group (P=.004) and $C_3$ and $M_3$ group presented statistically higher (P=.005) values. While adhesive failure was not seen in any of the groups, cohesive and combined patterns were seen in all groups. CONCLUSION. Based on the results of this in-vitro study, $Al_2O_{3-}$ sandblasting followed by liner application on conventionally sintered zirconia cores may be preferred to enhance bond strength.

A COMPARATIVE STUDY OF THE SHEAR BOND STRENGTH AND ADHESIVE FAILURE PATTERN OF METAL BRACKETS BONDED ON NATURAL TEETH AND PORCELAIN TEETH (자연 치관과 포세린 치관상에서 교정용 브라켓 부착시 전단 결합 강도와 파절 양상에 관한 비교 연구)

  • Lee, Hyun-Sun;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.195-204
    • /
    • 2008
  • Orthodontic brackets often need to be bonded to porcelain such as porcelain fused to metal crowns and porcelain jacket crowns. The purpose of this study was to evaluate the clinical usability of direct bonding system on porcelain teeth by measuring shear bond strength according to various conditions and observing adhesive failure patterns. The specimens, 20 maxillary premolars and 80 porcelain teeth that were produced by duplication of the labial surface of a maxillary first premolar were used and randomly divided into four groups of twenty teeth each. The 5 different preparation procedures tested: (1) application of 37% phosphoric acid on natural teeth, (2) sandblasting on porcelain surfaces, (3) sandblasting and application of 9.6% hydrofluoric acid on porcelain surfaces, (4) sandblasting and application of silane on porcelain surface, (5) sandblasting and application of 9.6% hydrofluoric acid and silane on porcelain surfaces. The metal brackets were bonded with Transbond $XT^{(R)}$ bonding material. The shear bond strength was tested by the micro universal testing machine(Kyung-Sung, Korea) and the amount of residual adhesive on the tooth surface after debonding was examined by stereoscope and assessed with an adhesive remnant index. The results of this study suggest that the direct bonding system on porcelain teeth with sandblasting, HF and porcelain primer is clinically useful.

  • PDF

An Efficient Scheduling Method Taking into Account Resource Usage Patterns on Desktop Grids (데스크탑 그리드에서 자원 사용 경향성을 고려한 효율적인 스케줄링 기법)

  • Hyun Ju-Ho;Lee Sung-Gu;Kim Sang-Cheol;Lee Min-Gu
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.7
    • /
    • pp.429-439
    • /
    • 2006
  • A desktop grid, which is a computing grid composed of idle computing resources in a large network of desktop computers, is a promising platform for compute-intensive distributed computing applications. However, due to reliability and unpredictability of computing resources, effective scheduling of parallel computing applications on such a platform is a difficult problem. This paper proposes a new scheduling method aimed at reducing the total execution time of a parallel application on a desktop grid. The proposed method is based on utilizing the histories of execution behavior of individual computing nodes in the scheduling algorithm. In order to test out the feasibility of this idea, execution trace data were collected from a set of 40 desktop workstations over a period of seven weeks. Then, based on this data, the execution of several representative parallel applications were simulated using trace-driven simulation. The simulation results showed that the proposed method improves the execution time of the target applications significantly when compared to previous desktop grid scheduling methods. In addition, there were fewer instances of application suspension and failure.

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.

SHEAR BOND STRENGTH BETWEEN TARGIS AND HUMAN DENTIN BY USING VARIOUS LUTING CEMEMTS (수종의 접착제를 이용한 Targis와 상아질간의 전단결합강도)

  • Lee, Jung;Yu, Mi-Kyung;Cho, Young-Gon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.519-527
    • /
    • 1999
  • The purpose of this study was to estimate shear bond strength according to difference in luting cements and Targis surface treatment. 70 non-carious extracted human molars and Targis shade D210(Ivoclar, Liechtenstein) were used in the present study and they were randomly assigned into 7 experimental groups ; Group 1 : specimens were bonded with using vitremer(3M, U.S.A). Group 2, 4, 6 : specimens were not-treated with silane and bonded with Panavia 21(Kuraray Japan), Choice(Bisco, U.S.A.) and Variolink II(Vivadent, Liechtenstein) respectively Group 3, 5, 7 : specimens were treated with silane and bonded with Panavia 21, Choice and Variolink II respectively. After the surface treatment, the luting cement was mixed by manufacturer's recommendation and then applied between dentin and Targis and excess cement was removed by brush. All specimens were stored for 24 hrs in distiled water at $37^{\circ}C$. Shear bond strength for each group was then measured. To examine the failure patterns of targis to dentin, specimens were fabricated and observed under the SEM. The results were as follows ; 1. The mean shear bond strength of the groups using resin cements was significantly higher than that using resin-modified GI cements (P<0.05). 2. There is no significant difference in shear bond strength between Panavia 21 and Choice whether silane was used or not(P>0.05). However, bond strength for the groups using Variolink II was higher in the specimens not-treated with silane than the treated specimens (P<0.05). 3. There is no significant difference in bond strength among the groups using silane surface treatment and resin cement (group 3, 5, 7) (P<0.05). 4. The proportions of the specimens showing the mixed fracture failure were 20% in groups using Panavia 21 and Variolink II and 15% in group using Choice.

  • PDF

COMPARISON OF THE SHEAR BOND STRENGTH OF GLASS IONOMER CEMENTS AND COMPOMER ACCORDING TO DENTIN SURFACE TREATMENT (상아질표면처리에 따른 글래스아이오노머 및 Compomer의 전단결합강도의 비교)

  • Jeong, Hyun-Suk;Lee, Hea-Joo;Hur, Buck
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.416-425
    • /
    • 1999
  • The purpose of this study was to evaluate shear bond strength of glass ionomer cements and compomer according to dentin surface treatment method. The materials used in this study were dentin conditioner and cavity conditioner for dentin treatment: Ketacfil, Fuji II LC, and Dyract for restoration. In this study, 90 sound bovine teeth were selected and then the teeth were embeded in improved stone and were grounded with 400 to 600 grit silicon carbide paper to create a flat dentin surfaces. The teeth were divided into nine groups as follows ; Group 1A : Samples bonded to dentin surface with Ketacfil after no treatment Group 1B : Samples bonded to dentin surface with Ketacfil after applicating dentin conditioner Group 1C : Samples bonded to dentin surface with Ketacfil after applicating cavity conditioner Group 2A : Samples bonded to dentin surface with Fuji II LC after no treatment Group 2B : Samples bonded to dentin surface with Fuji II LC after applicating dentin conditioner Group 2C : Samples bonded to dentin surface with Fuji II LC after applicating cavity conditioner Group 3A : Samples bonded to dentin surface with Dyract after no treatment Group 3B : Samples bonded to dentin surface with Dyract after applicating dentin conditioner Group 3C : Samples bonded to dentin surface with Dyract after applicating cavity conditioner Treated dentin surfaces were observed under SEM. After filling of each materials, shear bond strenth was evaluated and then debonded surfaces were observed under SEM. The following results were obtained; 1. The shear bond strengths obtained were decreased as Fuji II LC, Dyract, Ketacfil in that order and there was statistically significant difference(p<0.05). 2. About Group 1. the shear bond strengths were decreased as 1C, 1B and 1A in that order. But there was no significant difference between group 1B and 1C (p<0.05). 3. About Group 2, the shear bond strengths were decreased as group 2B, 2A and 2C in that order. And there was significant difference between group 2B and 2C (p<0.05). 4. About Group 3, the shear bond strengths were decreased as group 3A, 3C and 3B in that order. And there was signicant difference between group 3A and 3B (p<0.05). 5. As a result of observation under SEM, the fracture patterns of Fuji II LC and Dyract were adhesive failures, but those of Ketacfil were cohesive failure of material and mixture of cohesive and adhesive failure.

  • PDF