• Title/Summary/Keyword: factor of change

Search Result 4,724, Processing Time 0.034 seconds

Variation of Surface Crack Shape in Pressure Vessel Materials (압력용기 소재에서의 표면균열의 형상변화)

  • 허용학;이주진;이해무
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.617-623
    • /
    • 1990
  • Cracks present in pressure vessels have been reported to be mostly semi-elliptic surface cracks. The fatigue crack growth rates(FCGR) of surface cracks in the pressure vessel materials, API5A-K55 and SPV 500, used in this study were showed to be different depending on the direction of propagation of the surface crack. An equation for the prediction of the shape change of the surface crack was obtained by combining the Paris' relations for each direction of surface crack extension and agreed well with the experimental data. And also FGGR in both materials were evaluated and prediction of the shape change of surface crack were made using averaged stress intensity factor.

A Study on Space Recognition Change of the High School Students according to Geographic Information Quantities - Focused on Factors Influencing the Land Value - (지리 정보량에 따른 고등학생의 공간 인식 변화에 대한 연구 - 지가 형성 요인을 중심으로 -)

  • Shin, Yeong-Jae
    • Journal of the Korean association of regional geographers
    • /
    • v.17 no.4
    • /
    • pp.443-458
    • /
    • 2011
  • The purpose of this study is to research space recognition change of the high school students according to geographic information quantities, focused on Factors Influencing the Land Value. The region of case study was some places of Songtan Special Tourism Zone, which responding students were unfamiliar with. The results are as follows. First, through the results of analysing 'the highest valued standard land and choice reasons' in two ㄴregions of the old town and the new town, it is perceived that the relative factor of land is more important than the absolute factor as the factors influencing the land value of the highest valued standard land. Second, there are students' recognition differences in the choice reasons of the highest valued standard land of two regions which have different characteristics. Third, though in the same region, recognitions about factors influencing the land value change according to geographic information quantities, and as students' knowledge about geographic information increases, the choice rate of the highest valued standard land increases. Lastly, it is perceived that there is a facility which has a decisive effect on formating the land value of a certain region.

  • PDF

Monte Carlo study on the effect of reference depth change to the central electrode correction factor (기준깊이 변화에 따른 중심전극 보정인수(Pcel)변화)

  • Mln, Chul-Hee;Kim, Sung-Hun;Shin, Dong-Oh;Kim, Chan-Hyeong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.39-42
    • /
    • 2004
  • The Central Electrode Correction Factor that corrects the effect due to the electrode being made of non-air material is base on the data from the depth of 5cm in water. But TG-51 protocol proposes the reference depth of 10cm in water. The purpose of this research is to check the alteration of Central Electrode Correction Factor due to the change of reference depth from 5cm to 10cm in water using Monte Carlo Computing Methods. The results showed that the change of Central Electrode Correction Factor is ignorable in the statistical errors of 2% for two different depth, 5cm and 10cm.

  • PDF

The Evaluation of Sediment Yield of Dam-basin considering Future Climate Change in GIS Environment (미래 기후변화를 고려한 GIS 기반의 댐유역 유사량 평가)

  • Lee, Geun-Sang;Choi, Yun-Woong;Cho, Gi-Sung
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.383-385
    • /
    • 2010
  • This study analyzed the change of flowout and suspend solid in Andong and Imha basin according to the climate change to develop evaluation index about turbid water occurrence possibility and to support the countermeasures for turbid water management using GIS-based Soil and Water Assessment Tools (SWAT). MIROC3.2 hires model values of A1B climate change scenario that were supplied by Intergovernmental Panel on Climate Change (IPCC) were applied to future climage change data. Precipitation and temperature were corrected by applying the output value of 20th Century Climate Coupled Model (20C3M) based on past climate data during 1977 and 2006 and downscaled with Change Factor (CF) method. And future climate change scenarios were classified as three periods (2020s, 2050s, 2080s) and the change of flowout and suspended solid according to the climate change were estimated by coupling modeled value with SWAT model.

  • PDF

Protective Effect of Trophic Factor Supplementation on Cold Ischemia/Rewarming Injury to Kidney Cells (Trophic factor supplementation에 의한 cold ischemia/rewarming손상으로 부터의 신장 세포 보호)

  • Kwon, Young-Sam;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.25 no.5
    • /
    • pp.355-358
    • /
    • 2008
  • The aim of this study was to investigate whether trophic factor supplementation (TFS) enhance the survival of kidney cell during cold ischemic storage and rewarming. The effect of TFS on the phosphorylation of p44/42 and p38 mitogen activated protein kinases (MAPK) signaling pathway was determined by Western blot. Apoptotic changes after cold ischemic storage and rewarming was determined by 4',6'-diamino-2-phenylindole (DAPI) staining. The cell viability was evaluated by live assay. TFS significantly decreased p44/42 and p38 MAPK activity induced by cold ischemic injury and rewarming (p < 0.05). The number of apoptotic cells was decreased after 5 minute rewarming in the presence of TFS. TFS significantly increased the cell viability after 5 minute rewarming (p < 0.05). Therefore, it was concluded that trophic factor supplementation protects kidney tubule cells from cold ischemic and rewarming injury via the inhibition of p44/42 and p38 MAPK activation and reducing apoptotic change.

A Study on the Selection of Slack Bus at Application of Marginal Loss-Factor in a Competitive Electricity Market (경쟁적 전력시장에서 한계손실계수 적용시 기준모선 선정에 대한 연구)

  • Kim, Sang-Hoon;Lee, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.264-269
    • /
    • 2009
  • Marginal Loss Factor(MLF) is represented as the sensitivity of transmission loss, which is computed from the change of the generation at slack bus by the change of the load at the arbitrary bus. The MLF dependent on the selection of slack bus is one of the key factors affecting nodal pricing, Genco's profits, social welfare(SW) and Nash Equilibrium in a competitive electricity market. This paper addresses the methodology of slack bus selection by using Cournot model of Cost Based Pool market. Numerical results from sample cases show that the slack bus of MLF of the highest average is beneficial from the view points of SW.

Mutant cAMP Receptor Protein Binds to DNA without DNA Bending (DNA 벤딩(휨) 없이 돌연변이 cAMP 수용체 단백질의 결합)

  • Gang, Jong-Back
    • Journal of Life Science
    • /
    • v.16 no.7 s.80
    • /
    • pp.1225-1228
    • /
    • 2006
  • Cyclic AMP receptor protein (CRP) complexed with cAMP binds to DNA and induces sharp DNA bending around ${\sim}90$ degree. Previous publication (5), however, reported that mutant CRP:cGMP complex showed high migration rate relative to mutant CRP:cAMP complex on native polyacrylamide gel. To confirm DNA structural change in the presence of CRP and cyclic nucleotide, molar cyclization factor $(j_M)$ [13] was measured with 6 constructed DNA fragments. Nonlinear regression analysis of $j_M$ data indicated that mutant CRP did not induce DNA bending in the presence of cGMP but bent DNA in the presence of cAMP without any helical twist change in DNA.

A Study on Driver's Perception over the Change of the Headlamp's Illuminance : 3. Driver's psychological property (전조등 조도변동에 대한 운전자의 인식연구 : 3. 운전자의 심리적 특성)

  • Kim, Huyn-Ji;Kim, Hyun-Jin;Kim, Gi-Hoon;Kim, Hoon;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.19-26
    • /
    • 2006
  • In this study, psychological assessment was carried out to investigate the driver's psychological characteristics by the change of the headlight. The participants were 20 men and 20 women in their 20s and thirty-two different conditions in combinations of waveform of light, voltage, and alteration time were used. The questionnaire for the assessment was evaluated by 8 subjective item and 5-point SD criteria of 19 pair's adjective. The results were as follows : 1. The assessment results from SD method indicated 4 factors by factor analysis, and it was shown that A waveform had significances in a sense of security and impetus and B waveform had a significance in a sense of security. The levels of the limitations for the voltage change were 12[V] in the factor of a sense of security and 11[V] in the factor of a sense of impetus for A waveform, 12.6[V] in the factor of a sense of security for B waveform. 2. The results of the subjective assessment showed that the limitation of A waveform's brightness change was 12[V]. Moreover, the limitations of voltage changes were 12.67[V] for B waveform brightness change, 12.12[V] for discomfort, 12.71[V] for darkness. And the limitation of C waveform's brightness change was 12[V].

On-Site Calibration Technology of Burden using Voltage Transformer Comparator (전압변성기 비교기를 이용한 부담의 현장교정 기술)

  • Jung, Jae Kap;Kwon, Sung Won;Park, Young Tae;Kim, Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.503-507
    • /
    • 2005
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of VT burden used. Thus, precise measurement of burden is very important for the evaluation of VT. A method of evaluation for VT burden has been developed by employing the portable decade resistor, with AC-DC resistance difference less than 10-3. The burden value(value and power factor) can be obtained by conductance and susceptance, obtained by measuring the change of ratio error and phase angle error caused by the resistance change of decade resistor. The burden value and power factor obtained by the method are consistent with those obtained using power analyzer within corresponding uncertainties.

A Study on the Freeze-Thaw Resistance of Water-permeable Concretes (투수성 콘크리트의 동결융해 저항성에 관한 연구)

  • 은재기;김완기;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.433-438
    • /
    • 2000
  • The purpose of this study is to examine the resistance of water-permeable concretes to freezing and thawing action. The water-permeable concretes with cement-aggregate ratio of 1:5.5(by weight) and two kinds of admixture content [SP : superplasticizer(0, 1.0%), HPAE : high performance air entraining agent(0.5, 1%)] used OPC(ordinary portland cement) as binder were prepared, and then tested for relative dynamic modulus of elasiticity, mass change, length change and durablity factor. It's been concluded from the test results that the superior relative dynamic modulus of elasiticity and durability factor of water-permeable concretes were obtained at superplaciticizer 1.0% after 300 cycles. The water-permeable concretes used superplasiticizer 1.0% having relative durability factor of 88% after 300 cycles.

  • PDF