• Title/Summary/Keyword: facility standard

Search Result 930, Processing Time 0.026 seconds

A Study on Development and Analysis of Accident Influence Factor Verification Tools for the Elderly People in the Welfare Facilities for the Aged (노인주거 복지시설 거주 노인의 안전사고 영향변수 검증도구 개발 및 분석에 관한 연구)

  • You, Jong-Ok;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.242-248
    • /
    • 2011
  • According to a study on the accident patterns of older people in 2006 by Korea Consumer Agency (CISS), the number of accidents of the elderly at home reached 486, and the figure has increased every year. As Korea is about to enter into the aged society, it is important to investigate the factors that cause an accident in the welfare facilities for the aged and establish the barrier-free construction standards. The accident influence factors include facility environmental, physical functional, socio demographic and socio psychological factors. In terms of the verification tools, there are Facility Evaluation Index, FIM, MMSE-K and General Feature. In terms of analysis method, in addition, there are real number, percentage, t-test, ANOVA and logistic regression. In conclusion, this paper attempts to reveal correlations among the accident influence factors using the Facility Evaluation Standards (115 items in total) for facility environmental factor, FIM (3 items) for physical functional factor, MMSE-K (6 items) for socio psychological factor and questionnaire (5 items) for socio demographic factor.

A Study on the Elements of Architectural Planning Required in Healthcare Accreditation - Focused on Korea Healthcare Accreditation, JCI Hospitals Standard - (의료기관 인증제도에서 요구되는 건축계획요소에 관한 연구 - 국내 의료기관인증제도, JCI 병원인증기준을 중심으로 -)

  • Kim, Ui-Hyeon;Yang, Nae-Won
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.223-230
    • /
    • 2012
  • These days, hospitals in Korea have great interests in healthcare accreditation. The criteria of this accreditation has been established by management, but development of the management system without facility improvement has limits. Therefore this study reclassified domestic and foreign healthcare accreditation focusing on facilities and has purpose on proposing facility elements that can be adopted in hospitals. Also, the study is relevant to the study on architecture planning of hospital according to 'Patient safety' which will be suggested in the future and has significance for establishing basis of healthcare facility planning and for improving the existing facilities. The study selected facility lists from 'healthcare accreditation' and reclassified them based on departments in the hospital. Using these lists, the study divided the hospital that has obtained 'healthcare accreditation' into departments and investigated and analyzed them. On the basis of the analysis, the study suggested facility lists involved in hand washing, waste disposal, equipment washing, quarantine, goods-movement, establishing clean/polluted area, emergency exit-way, and restricted zone.

  • PDF

An Optimization Algorithm for the Two-Echelon Capacitated Facility Location Problem (용량 제약이 있는 이계층 설비 입지선정 문제의 최적화 해법)

  • Kim Eun Jeong;Gang Dong Hwan;Lee Gyeong Sik;Park Seong Su
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.137-144
    • /
    • 2003
  • We consider Two-echelon Single source Capacitated Facility Location Problem (TSCFLP). TSCFLP is a variant or Capacitated Facility Location Problem (CFLP). which has been an important issue in boa academic and industrial aspects. Given a set or possible facility locations in two echelons (warehouse / plant), a set or customers, TSCFLP is a decision problem to find a set or facility locations to open and to determine an allocation schedule that satisfies the demands or the customers and the capacity constraints or the facilities, while minimizing the overall cost. It ran be shown that TSCFLP Is strongly NP-hard For TSCFLf, few algorithms are known. which are heuristics. We propose a disaggregated version or the standard mixed integer programming formulation or TSCFLP We also provide a class or valid Inequalities Branch-and-price algorithm with rutting plane method Is used to find an optimal solution Efficient branching strategy compatible with subproblem optimization problems Is also provided. We report computational results or tests on 15 randomly generated instances.

  • PDF

A Study on Odor Dispersion Prediction of Waste Treatment Facilities Using CFD (CFD를 이용한 쓰레기 처리시설의 악취확산 예측에 관한 연구)

  • Kyung, Seo-Kyung;Kim, Kong-Sook;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.342-349
    • /
    • 2009
  • The purpose of this study is to estimate efficiently an odor dispersion from waste treatment facility for a crematory and a neighborhood facility, then propose planning, a location of an opening or the arrangement of the trees. Hence, offer a comfortable environment for a resident. For this, first the research data about estimating odor dispersion from waste treatment facility and odor are analyzed, then research an ingredient, characteristic, a direct effect for human and a method of measurement. Second, with on-site survey, check odorimetry and the source of odor dispersion, then apply this to the boundary condition of CFD simulation. Third, analyse by the hour for the 2008 standard weather data of Cheon-an, then apply summer data that odor dispersion is active, winter data relatively slow and an annual mean velocity and wind to the simulation. Even if a crematory and neighborhood facility located on south and north from waste treatment facility are at the low rate, the south and north wind will be applied to the simulation. Fourth, with CFD simulation result, predict an odor dispersion, then propose a solution which is considered an odor dispersion, a location of an opening and the arrangement of the trees. Consequently, this study will have an effect on an environment of a resident.

  • PDF

Update Facility for XML Schema (XML 스키마를 위한 갱신 기능)

  • Lee, Ki-Jun;Hwang, Soo-Chan
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.3
    • /
    • pp.324-330
    • /
    • 2010
  • XML schema is widely used as an effective tool for organizing and validating XML data. Although W3C released XQuery and XQuery Update Facility as the standard methods for searching and updating XML data, there is no consideration about providing facilities for updating XML schema itself until now. So users can only update an XML schema file directly by using editors. However, the direct update has several problems: It cannot prevent user's illegal update; it is hard to apply to the XML schemas stored in databases, needs much time to analyze schema, and is likely to make syntactic errors. In this paper, we propose an XML schema update facility, which enables creation, deletion and modification of XML schema by using commands.

Design and fabrication of beam dumps at the µSR facility of RAON for high-energy proton absorption

  • Jae Chang Kim;Jae Young Jeong;Kihong Pak;Yong Hyun Kim;Junesic Park;Ju Hahn Lee;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3692-3699
    • /
    • 2023
  • The Rare isotope Accelerator complex for ON-line experiments in Korea houses several accelerator complexes. Among them, the µSR facility will be initially equipped with a 600 MeV and 100 kW proton beam to generate surface muons, and will be upgraded to 400 kW with the same energy. Accelerated proton beams lose approximately 20% of the power at the target, and the remaining power is concentrated in the beam direction. Therefore, to ensure safe operation of the facility, concentrated protons must be distributed and absorbed at the beam dump. Additionally, effective dose levels must be lower than the legal standard, and the beam dumps used at 100 kW should be reused at 400 kW to minimize the generation of radioactive waste. In this study, we introduce a tailored method for designing beam dumps based on the characteristics of the µSR facility. To optimize the geometry, the absorbed power and effective dose were calculated using the MCNP6 code. The temperature and stress were determined using the ANSYS Mechanical code. Thus, the beam dump design consists of six structures when operated at 100 kW, and a 400 kW beam dump consisting of 24 structures was developed by reusing the 100 kW beam dump.

Research on composting of sewage sludge using dryer facility with indirect heating system (간접가온 건조방식의 건조시설을 이용한 하수슬러지 퇴비화에 관한 연구)

  • Baik, Seon-Jai;Han, In-Sup;Choi, Ick-Hoon;Kang, Sung-Hyo;Hong, Seong-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.299-304
    • /
    • 2014
  • The need of reusing sewage sludge is highly increasing as the amount of domestic sewage sludge is growing and sewage management strategies were reinforced. Accordingly, in this research, we studied the composting possibility of sludge in sewage treatment plant J, using dryer facility with indirect system by conducting component analysis of dried sludge and experiment on cultivating crops. It was observed from the component analysis, that the dried sludge is appropriate for both decomposed manure standard of Ministry of Environment and fertilizer standard of Rural Development Administration. Besides, in the experiment on cultivating lettuce, the experimental group(soil + dried sludge) was superior to the control group(soil + bed soil) in apparent condition of leaves tensity and damage by disease and pest. In case of cultivating tomato, the experimental group showed stronger durability of fruits dangling on stems compared to the control group after 9 weeks. Consequently, the excess sludge dried by indirect heating system in the sewage treatment plant J is appropriate for the standard of both Ministry of Environment and Rural Development Administration and show good result in experiment on cultivating crops therefore it can be reused for composting.

A Study on the Fire Risk of ESS through Fire Status and Field Investigation (화재현황 및 현장조사를 통한 ESS의 화재 위험성 연구)

  • Park, Kwang-Muk;Kim, Jae-Hyun;Park, Jin-Yeong;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.91-99
    • /
    • 2018
  • Recently, the spread of ESS in Korea has increased and a fire accident has also occurred. By July 2018, there were a total of 7 cases. All 7 cases were ESS systems consisting of lithium-ion batteries and were burned down. Both the automatic fire extinguisher and the fire department were not able to digest. In this paper, the characteristics of ESS fire are analyzed based on recent ESS fire situation and field investigation, and the cause of fire is divided into environmental, electrical and thermal factors. As a result, it was found that the ESS fire was correlated with the installation environment of the system. In the domestic and overseas lithium ion battery test standard and ESS facility standard survey, the trends and differences of domestic and overseas facilities standards were identified. Based on the fire status and field investigationy, and domestic and overseas facility standard survey, measures were suggested to prevent and prevent the spread of fire in ESS fire.

A Study on the direction for Facility Improvement of Nationally Designated Negative Pressure Isolation Ward through Post Occupancy Evaluation (거주 후 평가를 통한 국가지정 입원치료병상 시설 개선 방향 도출에 관한 연구)

  • Jeong, Dawoon;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.3
    • /
    • pp.39-49
    • /
    • 2021
  • Purpose: The negative pressure isolation ward is a key facility in preparedness and response to infectious diseases. For the sustainable operation of the facility, appropriate facility improvement is required. The experience of medical staff responding to infectious diseases in the COVID-19 pandemic provides effective informations for facility planning. Methods: The post occupancy evaluation (POE) was conducted by interviewing medical staff who is working on Nationally designated negative pressure isolation ward in general hospital. Floor plan analysis was conducted before field surveys for identifying facility characteristic and spatial composition. After that, field surveys were conducted at 3 hospitals, and interviews and fieldwork were conducted together. Results: It is necessary to increase the standard size of ward area from 15m2 to 20m2. The size of the doffing room has to be planned for accommodation of two or more people. Equipment storage, clean storage and waste storage also should be properly planned. There were almost no problems with the circulation in the ward. There was not enough space for medical staff. Implications: For a sustainable and safe negative pressure isolation ward planning, it is necessary to exploit learning from the medical staffs who have many experiences of coping with infectious diseases.

A Study on the Visualization of Facility Data Using Manufacturing Data Collection Standard (제조설비 데이터 수집 표준을 이용한 설비 데이터 시각화에 대한 연구)

  • Ko, Dongbeom;Park, Jeongmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.3
    • /
    • pp.159-166
    • /
    • 2018
  • This paper introduces a manufacturing facility visualization system for the monitoring of smart factories. With the development of technology and the emergence of such terms as the Fourth Industrial Revolution and Industry 4.0, technologies for smart factories are becoming more important. A Manufacturing Execution System that can improve productivity and help decision making by monitoring production plants in real-time is one of the key technologies for smart factories. The application of digital twin technology for more accurate monitoring technology is also an important issue. However, digital twin implementations require an integrated infrastructure that can integrate facility data from multiple manufacturers. Therefore, this paper designs and develops a visualization program that can verify real-time information of facilities using data collection system based on international standard protocol for heterogeneous collection and monitoring of facility data. This allows a factory to consolidate equipment data from multiple manufacturers and to view them in real-time.