Indicator of Facility Performance Evaluation (FPE) for Educational Facilities of BTL Projects

  • Lee, Kwan-Jong;Lee, Chun-Kyong;Park, Tae-Keun
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2012
  • Build-Transfer-Lease (BTL) was introduced to the domestic construction market in 2005. Now, seven years later, the BTL model is most active for educational facilities. In 2011, 93 educational facility projects entered the maintenance stage. Considering the characteristics of today's BTL projects for educational facilities, the main issues are the initial performance and maintenance of educational facilities and the service-providing status for the 20-year operational management period, in relation to providing safety and convenience to students, the facility users. Seeking a solution, local education offices and departments in charge of BTL under the Ministry of Education, Science, and Technology have been exploring various methods of evaluating operational maintenance performance from various perspectives. For educational facility BTL projects, however, the appropriateness of initial operation performance evaluation, rather than considering the 20-year operational management period, is controversial in regards to sustainability. On this account, performance evaluation items in four areas-operational maintenance evaluation, facility performance status evaluation, maintenance subject evaluation, and sustainable change response evaluation-should be extracted. An indicator of facility performance evaluation is presented in this study through an AHP survey targeting experts, as part of establishing an operation performance evaluation system for educational facility BTL projects.

Exploratory approach to measuring facility performance in public service facilities (공공서비스시설에서의 시설성능 요인에 대한 탐색적 연구)

  • Lee, So-Young;Shin, Hee-Young
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.284-287
    • /
    • 2009
  • In order to plan and manage public facilities effectively and efficiently, it is necessary to diagnose the current status of facilities and decide the objective features. Performance measurement is to provide managers with the information they need to measure competitive advantages. This paper discusses public facility performance in order to establish the conceptual framework for performance measurement for public facilities. In order to develop the measurement of public facility performance, a pilot study was conducted with facilities managers of facilities management corporation of public districts in Seoul. We investigated how public facilities management teams have assessed their performance and collected data regarding financial aspects, service aspects, community aspects, and building aspects. There is no standard format to measure facility performance since building sizes, programs, community needs widely differ. However, it is necessary to have a more consistent system to measure facility performance. In addition, each public municipal district needs to empower each district facilities management corporation to participate in managerial decisions and budget control.

  • PDF

Development of Turbopump Cavitation Performance Test Facility and the Test of Inducer Performance (터보펌프 Cavitation 성능시험기 개발 및 성능시험에 관한 연구)

  • Sohn, Dong-Kee;Kim, Chun-Tak;Yoon, Min-Soo;Cha, Bong-Jun;Kim, Jin-Han;Yang, Soo-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.619-624
    • /
    • 2001
  • A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar; rotational speed 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification.

  • PDF

Numerical Simulation of Rainfall Infiltration Into Disposal Cover of Performance Test Facility

  • Mijin Kwon;Seho Choi;Chunhyung Cho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.22 no.2
    • /
    • pp.185-199
    • /
    • 2024
  • Disposal cover as an engineered barrier of a near-surface disposal facility for low and very low-level radioactive waste is composed of a multi-layer to isolate radioactive waste from environmental influences for the long term. To acquire a realistic forecast for the post-closure period of the disposal facility, it is essential to carry out long-term experimental research in a similar condition to the actual disposal environment. Hence, a performance test facility of the disposal cover was constructed in Gyeongju low and intermediate level radioactive waste disposal center in 2022. The constructed performance test facility has differences from the material properties presented in the design. These differences are factors that affect the prevent rainfall infiltration, which is one of the important roles of the disposal cover. Therefore, in this study, a numerical simulation of rainfall infiltration into the performance test facility was performed for the designed case and the actual constructed case. To simulate the behavior of water infiltration, the FEFLOW software based on the finite element method is used. Through the analysis of numerical simulation results, it is confirmed that the hydraulic conductivity of the material constituting the multi-layer of the disposal cover greatly influences the amount of water infiltration.

Development of a Test Facility for Cold-air Performance of Small Axial Turbine (소형 축류터빈의 상온 성능시험기 개발)

  • 손창민;차봉준;이대성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1780-1786
    • /
    • 1995
  • The main goal of the present study is to establish the techniques and methodolgies of turbine performance test through evaluating the objective turbine test piece, and checking the reliability of the self-developed test facility by performing a series of turbine tests under ambient temperature condition. A high speed coupling, a lubrication system and a test bed of the test facility were modified through a series of preliminary test in order to reduce the vibration and oil leakage. The flowrate control of the test facility and data acquisition were accomplished by using a software called "Labview" The measurement of shaft horse power and control of rotational speed according to the conditions of turbine rotation were performed by a separate system. The preliminary evaluation of the measured data suggests that the developed test facility and the test technique can be used reliably for the performance test of turbines with the minor improvement.provement.

A Study on the model found of the duty factor whom follows in old person welfare facility worker holding office duration and organized performance research (노인복지시설 종사자 재직기간에 따른 직무요인, 조직성과의 모형정립에 관한 연구)

  • Cho, Woo-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.11
    • /
    • pp.233-239
    • /
    • 2010
  • The research which sees the fact that about model found of the duty factor whom follows in old person welfare facility worker holding office duration and organized performance researches in purpose. From theoretical background about the old person welfare facility system investigated a theory about the duty factor and organized performance of literature investigation and the old person welfare facility worker. A theory analysis of positive data led based on about the effect factor of the causality which the duty factor of the old person welfare facility worker reaches in organized performance under verifying boil the modulating effect of holding office duration. The repair which is a duty factor of the old person welfare facility worker, according to the holding office duration which is a personal quality factor job satisfaction the promotion and organized natural features, business environment and organized structure are organized performance and organization immersion and loyalty degree different assumed with the fact that will affect. From positive analysis about the research object verifies a suitable degree about demographics school register analytical and study model, structural equation model leads and construction verification and modulating effect analysis under executing boil.

Hydraulic Performance Test of a Turbopump Inducer in Liquid Nitrogen (액체질소를 이용한 터보펌프 인듀서의 수력성능시험)

  • Kim, Jin-Sun;Hong, Soon-Sam;Kim, Jin-Han
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.348-353
    • /
    • 2005
  • A cryogenic test facility has been developed to perform inducer and pump tests using liquid nitrogen. Performance tests of a turbopump in the maximum 50ton-thrust class can be performed with cryogenic fluid in the facility which operates at a temperature around $-196^{\circ}C$ with the rotational speed up to 30,000rpm. To verify the reliability of the cryogenic pump test facility, hydraulic performance tests of an inducer were accomplished, and their results were compared with the result from a water test The results confirm the reliability of the cryogenic test facility, and it is expected to contribute for on-going development of a turbopump for liquid rocket engines.

  • PDF

Hydraulic Performance Test of a Turbopump Inducer using Liquid Nitrogen (액체질소를 이용한 터보펌프 인듀서의 수력성능시험)

  • Kim Jin-Sun;Hong Soon-Sam;Kim Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.20-26
    • /
    • 2006
  • A cryogenic test facility has been developed to perform inducer and pump tests using liquid nitrogen. Performance tests of a turbopump in the maximum 50ton-thrust class can be performed with cryogenic fluid in the facility which operates at a temperature around -196oC with the rotational speed up to 30,000rpm To verify the reliability of the cryogenic pump test facility, hydraulic performance tests of an inducer were accomplished, and their results were compared with the result from a water test. The results confirm the reliability of the cryogenic test facility, and it is expected to contribute for on-going development of a turbopump for liquid rocket engines.

An Improved Facility Management System for Public Facility Management Corporations (공공 시설관리기관의 시설관리시스템 개선에 관한 연구)

  • Kim, ChangDuk;Lee, HyunChul
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.1
    • /
    • pp.32-42
    • /
    • 2018
  • The importance of facility maintenance management cannot be overemphasized in that not only the value but also the performance of the facility is determined by the level of maintenance. The maintenance cost of the facility ranges from 3 to 10 times the initial construction cost depending the type and use of the facility over the life span. This maintenance importance is increased for the group of facilities and even more critical when the facilities compete for the limited budget with the limited resources such as manpower and equipment. This study analyzed sixteen public facility management corporations primarily for three items: 1) facility management system, 2) long-term rehabilitation plan, 3) the rehabilitation selection system. This paper provides and recommends the key elements of the facility maintenance management system based on the analysis of the sixteen corporations.

A Study of Port Facility Maintenance and Decision-making Support System Development (항만시설 유지관리 의사결정 지원 시스템 개발 연구)

  • Na, Yong Hyoun;Park, Mi Yeon;Choi, Doo Young
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.290-305
    • /
    • 2022
  • Purpose: Currently, port facility informatization technology is focused on the planning and design phases, so the necessity of research and technology development on the port facility maintenance system based on life cycle-level information is emphasized. Method: Based on the maintenance history data of port facilities and facility operation information, from the perspective of the life cycle of port facilities, the system is configured to enable maintenance decisions for port facilities through analysis of aging patterns, performance degradation prediction models, and risk analysis and proposed a method of expressing information. Result: A function was developed to simultaneously display the SOC performance evaluation and the comprehensive performance evaluation developed in this study, so that mid-to long-term maintenance and reinforcement and facility expansion can be applied and comparatively judged. Conclusion: The integrated port performance system developed in this study induces and supports the risk minimization of port facility management by proactively promoting appropriate repair and reinforcement measures through historical and operational information on port facilities.