The global standard realizing process of the Automobile Assembly Facility

  • Nashimoto, Tomoo
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.24-25
    • /
    • 2015
  • To realize the global standard of the assembly facility, one of key point is an influence of local characteristic. The global standardized information could be a useful input, especially at the beginning stage of the project. The content should be carefully checked against local requirements, in order to develop an Assembly Facility design to meet local regulations & characteristics. The level of input information required in each step is different depend on regions & countries. At an execution stage of the project, the global standard input needs to be updated as customized final input for the construction. There will be many issues to be clarified and coordinated so that the Assembly facilities meet the final requirements for the production technology. As a result, it is important to understand the timing to use the global standard information and the contents what is needed to adapt to the local characteristics. And close collaboration between production technology team and facility team is always required.

  • PDF

A Study on the Architectural Characteristics of Large and Multipurpose Elderly Welfare Facility in Germany (독일의 복합적인 형태의 노인복지시설과 대규모 노인복지시설의 건축적 특성에 관한 연구)

  • Lee, Yong-Kwang
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.3
    • /
    • pp.7-14
    • /
    • 2006
  • The purpose of this study was to analyze the elderly welfare facilities in Germany, which already entered into the aging society. Especially, the multipurpose and large elderly welfare facilities, where more than 50 elderly people lived, were analyzed. For this purpose, a field study was conducted between January 13 and February 3, 2005. This study tried to find out the architectural characteristics and trends of elderly welfare facility. There are about 9200 elderly welfare facilities in Germany, and about 7% of the elderly people over 65 years old live there. As for the multipurpose elderly welfare facilities, there are about 5800 facilities, 64% of the total facilities. The elderly welfare facility carries out single function at the early stage, and adds up another functions step by step. In general, the facility is managed with focusing on two main functions (care function and residential function). In a small town, the care function is the major one of the facility. However, in the city, the major functions of the facilities are both care and residential function, which are elderly residence or safeguard house.

  • PDF

The Effects of Patient and Facility Characteristics On the Resource Use by the Elderly in Long-term Care Services (환자 및 시설 특성이 장기요양서비스 이용 노인의 자원소모량에 미치는 영향)

  • 권순만;김홍수;김선민
    • Health Policy and Management
    • /
    • v.12 no.1
    • /
    • pp.21-53
    • /
    • 2002
  • The purpose of this study is to measure the resource use of the elderly in long-term care services and to examine the effects of patient and facility characteristics on their use of resources. The data were collected from 510 old people over sixty years of age, residing in five long-term care hospitals and two skilled nursing homes during the period between December 1, 2000 and February 28, 2001. For a full sample, when the first level of RUG(Resource Use Group)-III categories were employed as the proxy of patient severity, facility characteristics, such as location, size and ownership, have large effects on the resource use measured by service intensity, whereas patient characteristics such as severity have little or no effect. The resource use is significantly high if the facility: (1) is located in rural areas (gun): (2) has mare than 200 beds; (3) is a long-term care hospital; (4) is private; and (5) has a low percentage of medical aid patients. The analysis of the resource use in each RUG-III categories, for which ADL(Ability of Daily Living) were employed as the prosy of patient severity, shows a similar result. The loose relationship between the needs of residents and the resource use seems to be closely associated with the ineffective reimbursement system for providers. The current reimbursement system has no provision for quality improvement and reimburses facilities simply according to their types: fee-for-service for long-term care hospitals, and monthly-flat-rate or full-coverage-national-aid for skilled nursing facilities. It will be necessary to develop a more reasonable reimbursement system that takes patient's severity into account and gives incentives for long-term care providers to offer cost-effective services.

Starting Characteristics Study of Scramjet Engine Test Facility(SETF) (스크램제트 엔진 시험설비의 시동특성 연구)

  • Lee, Yang-Ji;Kang, Sang-Hun;Oh, Joong-Hwan;Yang, Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.2
    • /
    • pp.15-22
    • /
    • 2011
  • Unlike most aerodynamic wind-tunnel, Scramjet Engine Test Facility(SETF) of Korea Aerospace Research Institute should simulate enthalpy condition at a flight condition. SETF is a blow-down type, high-enthalpy wind tunnel. To attain a flight condition, a highly stagnated air comes into the test cell through a supersonic nozzle. Also, an air ejector of the SETF is used for simulating altitude conditions of the engine, and facility starting. SETF has a free-jet type test cell and this free-jet type test cell can simulate a boundary layer effect between an airplane and engine using facility nozzle, but it is too difficult to predict the nature of the facility. Therefore it is required to understand the starting characteristics of the facility by experiments. In this paper, the starting characteristics of the SETF and modifications of the ejector are described.

Starting Characteristics Study of Scramjet Engine Test Facility(SETF) (스크램제트 엔진 시험설비의 시동특성 연구)

  • Lee, Yang-Ji;Kang, Sang-Hun;Oh, Joong-Hwan;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.451-458
    • /
    • 2010
  • Unlike most aerodynamic wind-tunnel, Scramjet Engine Test Facility(SETF) of Korea Aerospace Research Institute should simulate enthalpy condition at a flight condition. SETF is a blow-down type, high-enthalpy wind tunnel. To attain a flight condition, a highly stagnated air comes into the test cell through a supersonic nozzle. Also, an air ejector of the SETF is used for simulating altitude conditions of the engine, and facility starting. SETF has a free-jet type test cell and this free-jet type test cell can simulate a boundary layer effect between an airplane and engine using facility nozzle, but it is too difficult to predict the nature of the facility. Therefore it is required to understand the starting characteristics of the facility by experiments. In this paper, the starting characteristics of the SETF and modifications of the ejector are described.

  • PDF

A Study on Characteristics of Lodging Facility Design in Domestic Resort Complexes - Focus on the Guestrooms of Condominium - (국내 복합리조트 숙박시설의 실내디자인특성 분석 - 콘도미니엄 객실을 중심으로 -)

  • Han, Jeong-Won
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.2
    • /
    • pp.186-196
    • /
    • 2010
  • According to the rapid changes in our society and lifestyles, the methods of spending leisure time are being diversified and the facilities for leisure activities are growing as multi-purposed complexes. Purpose of this study was to figure out the design changes of lodging facility interiors in resort complexes which had been influenced by socio-economic conditions after the year 2000, and to provide fundamental references for planning pleasant and differentiated resort accommodations. To accomplish this purpose, the recent tendency of making complex resort facilities was examined and the changes in the properties of lodging facility design since the year 2000 was analyzed. The result shows that the surface areas of guestroom units have been enlarged, and the composition of floor plans has been diversified into various types. Also the number of bathrooms and built-in furniture units has been increased. For the design properties, concepts and themes for guestroom design has been diversified by applying unique color schemes and design elements. The characteristics of lodging facility design in domestic resort complex have been developed to reflect social trends and customer needs. Nevertheless, to deal with changing culture of leisure life, continuous study on resort facilities and various types of lodging facility is required.

A study on the space composition and area planning of neonatal intensive care unit through the case of regional neonatal intensive care centers (신생아 집중치료 지역센터 사례를 통해 본 신생아 집중치료실(NICU) 공간 구성 및 면적 계획에 관한 연구)

  • Lee, Kee hwan;Park, Seo won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.1
    • /
    • pp.7-17
    • /
    • 2024
  • Purpose: This study is to present basic data and standards for calculating the space composition and area required when planning a neonatal intensive care unit. Methods: Review domestic and foreign facility standards and regulations related to the current neonatal intensive care unit, select a regional neonatal intensive care center designated by the Ministry of Health and Welfare as a case hospital, and organize a space program for the construction plan of the neonatal intensive care unit through analysis of characteristics such as facility size and function composition. Results and Implications: The size, facility area, and detailed room composition characteristics of the neonatal intensive care unit in Korea were confirmed, and essential rooms and appropriate areas were derived when planning the construction of the neonatal intensive care unit. Korea's legal facility standards related to neonatal intensive care units are lower than the actual hospital status and overseas standards, and the facility standards of the medical law need to be improved.

A study on the Analysis of Actual Condition of Residental Environment for the Eldery Residing in Daejeon (대전시 노인의 거주환경실태 조사연구)

  • 박정아;이지숙
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.175-183
    • /
    • 2004
  • The purpose of this study was to identify the actual condition of residential environment for the elderly residing in Daejeon. The data were collected through interviews and structured questionnaires. The sujects were 583 elderly people over the age of 65 in Daejeon. Sociodemographic characteristics, living characteristics, housing characteristics, neighborhood environment types, actual usage condition of neighborhood environment, relationship between sociodemographic characteristics and actual usage of neighborhood environment, actual condition of unit interior, were surveyed. The data were analyzed with frequency, percentage, χ²-test, mean using the SPSS package. The major findings were as follows. Features of unit interior which pointed generally were deterioration, soundproofing and size. Features of unit interior which need to be carefully planned were removal of height difference of entrance, removal of the thresholds, installation of emergency bell and room heating control facility. The facilities provided highly within the subject's residential environment were the eldery facility, church, hospital, bank, restaurant, beauty salon/barbershop, supermarket. and the facilities provided lowly were recreational facility, library, elderly school.

Detection Characteristics of a Novel Coupler for GIS PD Detection

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kim, Ik-Soo;Kim, Jae-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.224-229
    • /
    • 2003
  • An ultra high frequency (UHF) coupler possessing ultra wide band (UWB) characteristics ranging from hundreds of MHz to several GHz is desirable for the detection of the partial discharge (PD) pulses because the pulses propagate with rise time shorter than one nanosecond in a gas-insulated substation (GIS). Thus, the authors have proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, and coupler geometry were considered throughout the simulations. The experiments for the detection characteristics of the coupler were carried out in the mock-up GIS chamber. The results indicated that the detection characteristics of the coupler are dependent on the installation angle of the coupler, the position of the coupler in the hand hole and the existence of the spacer.

Propagation Characteristics of GIS PD Signals by Dual UHF Band Method (2)

  • Choi, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.136-139
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the propagation characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, propagation characteristics of GIS PD signals were measured in the mock-up GIS bus and it was found that the propagation characteristics of the high band showed a better result in accordance with the infernal configuration of the GIS bus than those of the full band.

  • PDF