In this study, the management and improvement of public small-scale sewage treatment facilities was investigated. In order to improve the effective management of the operation of small-scale sewage treatment facilities, treatment methods and the problems associated with sewage treatment were carefully addressed based on the data and literature. The investigation results showed that sewer pipes in rural areas should be repaired to prevent sewage from leaking and small-scale operations should be required to have effective management for pollutant loads less than 50%. Also, new methods should be developed for low concentrations of sewage. A law associated with FRP treatment facilities should be established and local governments need to supervise these operations to avoid insufficient and faulty construction. It is recommended that new facilities are built with advanced treatment techniques when the old facility can not comply with nitrogen and phosphorous discharge limits. Moreover, the study shows that nutrient and coliform treatment efficiency improves when abandoned facilities are renovated with the installation of nitrification/denitrification and disinfection processes or another advanced process.
Journal of Korean Society for Geospatial Information Science
/
v.16
no.2
/
pp.23-29
/
2008
This study deals with the systematic classification and analysis of urban facilities as a fundamental foundation of the intelligent and active management of urban facilities using Ubiquitous Sensor Network(USN). In the results of recent studies, the necessities and simple examples of USN application were already shown, but there were few studies about the systematic classification and specific application methods considering characteristics of urban facilities. In this study, we try to classify the main management characteristics of facilities and analyze the results, furthermore to contribute to the development of convergence of facility management and USN technology.
The purpose of this study is to analyze contents on media about the problems of long-term care facilities. For achieving this purpose, we reviewed 'KINDS(http://www.kinds.or.kr/)' from July, 2008 to May, 2012 which was an synthetic newspaper and TV news searching system. Among 320 articles, we finally analyzed 72 articles: 218 articles were duplicated and 30 articles did not directly related or were not objective. The results were divided with seven parts: 'long-term care facilities', 'employee' 'health care and accidents', 'providing and management of service', 'meals related problems', 'maltreatment of client', 'disorders & unfairness long-term care benefit. Among these seven parts, we could confirm specific and major problems, which were lack of safety management, incompleteness facilities & equipments, shortage of long-term care manpower, insufficient service providing low quality of service, hiding money from elderly's accounts, and providing some money to get national subsidies. For resolving these problems, the long-term service guidelines must be prepared and the related facilities must cooperate each other for providing high quality of service. In addition, the efficient systems must be made to find out long-term care problems and unfairness of service providing and strict management rules or sanctions must be needed.
This study investigated the maintenance and management of government office building in Dongnaebu, Gyeongsangdo in the mid-19th century. In the late Joseon Dynasty, Dongraebu was an important point of national defense and a place of trade and diplomacy with Japan, so it had many government facilities. There are very few government facilities remaining today, and no structure remains. Therefore, it is possible to grasp information about the government facilities through the old materials. Currently, there are public documents related to the local government offices such as Eupji, Eupsarye, and Junggi. Through comparison between public documents, we will examine the maintenance and management of Dongnaebu government facilities in the mid-19th century. As a result of the research, Dongnaebu government facilities were supervised by department and managed like articles. In addition, the name, size, and changes were all recorded in the management of the goods, and the authority of responsibility was clearly stated. This result is because the remaining material has the purpose of preparation as an accounting book. As a result, it was found that the government facilities in the late Joseon Dynasty were managed by a systematic department with clear authority.
Proceedings of the Korean Institute of Building Construction Conference
/
2022.04a
/
pp.41-42
/
2022
The management of defects in barracks facilities is carried out in such a way that defects found by the facility's manager are listed and requested to be repaired by the contractor. However, the standards and methods for the inspection of defects in the management of these defects are not specified in detail, so it is difficult to check the defects in detail. In response, the study first analyzed the current status of the number of defects that occurred in 2021 at official residences and barracks of certain units. As a result of the analysis, the number of defects that were not taken care of and that were not taken until the previous month was more than 10 cases on average per month. In order to reduce the number of such defects, major improvements in the field, timing, and safety inspection were found after the inspection of the military's facilities and safety, and the analysis of the manual of maintenance management. In addition, items for improvement of the checklist were derived through an analysis of the repair of defects caused by the unit's official residence and a total of 10 barracks facilities. Based on this, a checklist was proposed to manage defects in barracks facilities through interviews with military facility managers.
In Korea, the Ministry of Environment's Chemical Control Act is the basis for hazardous chemical substances and safety management is being carried out. In particular, the standards for the installation and management of facilities are strongly managed. There were problems in the early stages of implementation, conflict with other laws, size of facilities and non-reflection of material properties. In this study, more realistic and reasonable improvement was planned for the fire-resistance standard of buildings among these facilities. We compared the fire resistance standards of buildings in the Korean similar chemical facility safety management ordinance. Key problems were identified through examples of representative complaints concerning the criteria for facilities. Finally, the Chemical Control Act provided an improvement measure to apply the building fire-resistance standard by clarifying the size and chemical of facilities. In the future, the results of this study are expected to be consistent with the basic purpose of the Chemicals Contral Act considering environmental hazards and contribute to the standard of handling facilities of reasonable chemical management laws that can be applied to the industry in reality.
Journal of Korean Society for Geospatial Information Science
/
v.15
no.1
s.39
/
pp.61-66
/
2007
The final object of this research is to construct general management system that can manage diverse facilities of city on the basis of ubiquitous technology. Defining data format of items in each management, type and code for the urban facilities, the researcher designed database of urban facilities through the process of establishing logic model and data modelling. By inputting designed database into RFID Tag of each urban facilities and using RFID Reader and PDA, the researcher developed system that can efficiently manage the basic attributes and information and management information of urban facilities. Applying the general management system for urban facilities constructed on the basis of ubiquitous, the researcher could check the information of target facilities and input revised data. Further, it was found that the characteristics of RFID Tag and GPS should improve the optimal hardware combination and PDA performance for the surrounding environmental influence and system performance.
In this study, legislative and policy issues related to advancing the maintenance system of water resource facilities were presented by investigating and analyzing the degree of aging and management status of water resource facilities. Data from the comprehensive Facility Management System (FMS) operated by the Korea Infrastructure Safety Corporation were collected and used to analyze the aging of water resource facilities. Using safety grade data categorized by facility, type, local area, and grade, the ratio of dangerous facilities and the aging rate were calculated to analyze the status of water resource facilities and guidelines and manuals related to water resource facilities were investigated. Through this, four required actions to address legislative and policy issues were presented: 1) Readjusting the scope of water resource facilities and supplementing guidelines and manuals, 2) Establishing a maintenance system considering changes in disaster conditions, 3) Improving the FMS and activating standard linkage services, and 4) Establishing a facility asset management system.
Proceedings of the Korea Technology Innovation Society Conference
/
2000.11a
/
pp.161-175
/
2000
This study includes the fundamental planning of the sectoral management technology in energy distribution system so that the industry itself would be willing to participate for the effective energy conservation in its own sector. Furthermore guidlines for the effective energy management techniques have been presented by first analyzing the energy consumption structures, the energy loss problems, the energy conservation status and the technology demands, and second classifying, according to the energy distribution system, the energy source management, the energy generation & conversion facilities, the energy transportation & storage facilities, the energy consumming facilities and the waste energy management, etc. in the industrial sector.
Journal of the Korea Institute of Information and Communication Engineering
/
v.13
no.11
/
pp.2361-2366
/
2009
Usually, it is possible for human administrator to control the facilities manually or automatically using sensors in order to manage the fixed electricity facilities. However, it is difficult to collect the status data of those facilities in the central management system. In this paper, we propose the electricity facility management system to collect the status of facilities using the Zigbee networks. the proposed system exploits the various types of sensors, such as motion, heat, optical, etc, to measure the states of the facilities.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.