• 제목/요약/키워드: extraction solvent method

검색결과 600건 처리시간 0.024초

테르페나딘 체내동태 연구를 위한 혈청 중 펙소페나딘의 HPLC 정량법 개발 및 검증 (Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fexofenadine in Human)

  • 조혜영;강현아;김윤균;최후균;이용복
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권6호
    • /
    • pp.437-443
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of a major metabolite of terfenadine, fexofenadine, in human serum was developed, validated, and applied to the pharmacokinetic study of terfenadine. Fexofenadine and internal standard, haloperidol were extracted from human serum by liquid-liquid extraction with acetonitrile and analyzed on a $Symmetry^{TM}$ C8 column with the mobile phase of 1% triethylamine phosphate (pH 3.7)-acetonitrile (67:33, v/v, adjusted to pH 5.6 with triethylamine). Detection wavelength of 230 nm for excitation, 280 nm for emission and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fexofenadine concentration (50 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 10 ng/mL, which was sensitive enough for the pharmacokinetic studies of terfenadine. The overall accuracy of the quality control samples ranged from 95.70 to 114.58% for fexofenadine with overall precision (% C.V.) being 3.53-14.39%. The relative mean recovery of fexofenadine for human serum was 90.17%. Stability studies (freeze-thaw, short-term, extracted serum sample and stock solution) showed that fexofenadine was stable during storage, or during the assay procedure in human serum. However, the storage at $-70^{\circ}C$ for 4 weeks showed that fexofenadine was not stable. The peak area and retention time of fexofenadine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fexofenadine in human serum samples for the pharmacokinetic studies of orally administered Tafedine tablet (60 mg as terfenadine) at three different laboratories, demonstrating the suitability of the method.

에토돌락 체내동태 연구를 위한 혈청 중 에토돌락의 HPLC 정량법 개발 및 검증 (Development and Validation of an HPLC Method for the Pharmacokinetic Study of Etodolac in Human)

  • 조혜영;강현아;문재동;최후균;이용복
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권4호
    • /
    • pp.265-271
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of etodolac in human serum was developed, validated, and applied to the pharmacokinetic study of etodolac. Etodolac and internal standard, ibuprofen were extracted from human serum by liquid-liquid extraction with hexane/isopropanol (95:5, v/v) and analyzed on a Luna C18(2) column with the mobile phase of 1% aqueous acetic acid-acetonitrile (4:6, v/v). Detection wavelength of 227 nm and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed etodolac concentration $(1\;{\mu}g/mL)$ with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of $0.05-40\;{\mu}g/mL$ with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 0.05 ${\mu}g/mL$, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 92.00 to 110.00% for etodolac with overall precision (% C.V.) being 1.08-10.11%. The percent recovery for human serum was in the range of 76.73-115.30%. Stability studies showed that etodolac was stable during storage, or during the assay procedure in human serum. The peak area and retention time of etodolac were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of etodolac in human serum samples for the pharmacokinetic studies of orally administered Lodin XL tablet (400 mg as etodolac) at three different laboratories, demonstrating the suitability of the method.

페노프로펜 체내동태 연구를 위한 혈청 중 페노프로펜의 HPLC 정량법 개발 및 검증 (Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fenoprofen in Human)

  • 조혜영;강현아;김윤균;사홍기;이용복
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권6호
    • /
    • pp.423-429
    • /
    • 2005
  • A selective and sensitive reversed-phase HPLC method for the determination of fenoprofen in human serum was developed, validated, and applied to the pharmacokinetic study of fenoprofen calcium. Fenoprofen and internal standard, ketoprofen, were extracted from human serum by liquid-liquid extraction with diethyl ether and analyzed on a Luna C18(2) column with the mobile phase of acetonitrile-3 mM potassium dihydrogen phosphate (32:68, v/v, adjusted to pH 6.6 with phosphoric acid). Detection wavelength of 272 nm and flow rate of 0.25 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fenoprofen concentration $(2\;{\mu}g/mL)$ with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of $0.05-100\;{\mu}g/mL$ with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was $0.05\;{\mu}g/mL$, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 92.27 to 109.20% for fenoprofen with overall precision (% C.V.) being 5.51-11.71 %. The relative mean recovery of fenoprofen for human serum was 81.7%. Stability (freeze-thaw, short and long-term) studies showed that fenoprofen was not stable during storage. But, extracted serum sample and stock solution were allowed to stand at ambient temperature for 12 hr prior to injection without affecting the quantification. The peak area and retention time of fenoprofen were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fenoprofen in human serum samples for the pharmacokinetic studies of orally administered Fenopron tablet (600 mg as fenoprofen) at three different laboratories, demonstrating the suitability of the method.

디피리다몰 체내동태 연구를 위한 혈청 중 디피리다몰의 HPLC 정량법 개발 및 검증 (Development and Validation of an HPLC Method for the Pharmacokinetic Study of Dipyridamole in Human)

  • 조혜영;강현아;문재동;최후균;이용복
    • Journal of Pharmaceutical Investigation
    • /
    • 제36권1호
    • /
    • pp.45-51
    • /
    • 2006
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of dipyridamole in human serum was developed, validated, and applied to the pharmacokinetic study of dipyridamole. Dipyridamole and internal standard, loxapine, were extracted from human serum by liquid-liquid extraction with diethyl ether and analyzed on a Nova Pak $C_{I8}$ column with the mobile phase of 40 mM ammonium acetate:methanol:acetonitrile (35:35:30)(v/v/v, pH 7.8). Detection wavelength of 280 nm and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed dipyridamole concentration (50 ng/mL) with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 2-2000 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 2 ng/mL, which was sensitive enough for pharmacokinetic studies of dipyridamole. The overall accuracy of the quality control samples ranged from 103.94 to 105.86% for dipyridamole with overall precision (% C.V.) being 4.60-11.49%. The relative mean recovery of dipyridamole for human serum was 97.64%. Stability studies showed that dipyridamole was stable during storage, or during the assay procedure in human serum. The peak area and retention time of dipyridamole were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of dipyridamole in human serum samples for the pharmacokinetic studies of orally administered Dimor tablet (75 mg as dipyridamole) at three different laboratories, demonstrating the suitability of the method.

염산프로메타진 체내동태 연구를 위한 혈청 중 프로메타진의 HPLC 정량법 개발 및 검증 (Development and Validation of HPLC Method for Pharmacokinetic Study of Promethazine in Human)

  • 조혜영;강현아;이화정;최후균;이용복
    • Journal of Pharmaceutical Investigation
    • /
    • 제36권1호
    • /
    • pp.23-29
    • /
    • 2006
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of promethazine in human serum was developed, validated, and applied to the pharmacokinetic study of promethazine. Promethazine and internal standard, chlorpromazine, were extracted from human serum by liquid-liquid extraction with n-hexane containing 0.8% isopropanol and analyzed on a Capcell Pak CN column with the mobile phase of acetonitrile-0.2 M potassium dihydrogen phosphate (42:58, v/v, adjusted to pH 6.0 with 1 M NaOH). Detection wavelength of 251 nm and flow rate of 0.9 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed promethazine concentration (10 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 1-40 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was 1 ng/mL, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 96.15 to 105.40% for promethazine with overall precision (% C.V.) being 6.70-11.22%. The relative mean recovery of promethazine for human serum was 63.54%. Stability (freeze-thaw and short-term) studies showed that promethazine was stable during storage, or during the assay procedure in human serum. However, the storage at $-80^{\circ}C$ for 4 weeks showed that promethazine was not stable. Extracted serum sample and stock solution were not allowed to stand at ambient temperature for 12 hr prior to injection. The peak area and retention time of promethazine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of promethazine in human serum samples for the pharmacokinetic studies of orally administered Himazin tablet (25 mg as promethazine hydrochloride) at three different laboratories, demonstrating the suitability of the method.

Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula

  • Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • 한국축산식품학회지
    • /
    • 제35권4호
    • /
    • pp.466-472
    • /
    • 2015
  • A rapid and simple analytical method, using liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed to detect myo-inositol (MI) in infant formulas. For protein removal: acid hydrolysis and lipid removal through organic solvent extraction. The operating conditions for instrumental analysis were determined based on previously reported analogous methods that used LC-MS/MS. Quantitative analysis was used for the detection limit test, infant formula recovery test, and standard reference material (SRM) 1849a to verify the validity of our LC-MS/MS analytical method, which was developed to quantify MI. For validation, the results of our method were compared with the results of quantitative analyses of certified values. The test results showed that the limit of detection was 0.05 mg/L, the limit of quantitation was 0.17 mg/L, and the method detection limit was 17 mg/kg. The recovery test exhibited a recovery between 98.07-98.43% and a relative standard deviation between 1.93-2.74%. Therefore, the result values were good. Additionally, SRM 1849a was measured to have an MI content of 401.84 mg/kg and recovery of 98.25%, which is comparable to the median certified value of 409 mg/kg. From the aforementioned results, we judged that the instrumental analysis conditions and preparation method used in this study were valid. The rapid analytical method developed herein could be implemented in many laboratories that seek to save time and labor.

이차전지(二次電池) 제조공정(製造工程)스크랩으로부터 고효율(高效率) 親環境(친환경) 코발트(Co)와 리튬(Li)의 회수(回收)에 관(關)한 연구(硏究) (A Study on the Cobalt and Lithium Recovery from the Production Scraps of Lithium Secondary Battery by High Efficient and Eco-friendly Method)

  • 이정주;정진도
    • 자원리싸이클링
    • /
    • 제19권6호
    • /
    • pp.51-60
    • /
    • 2010
  • 리튬이차전지 양극스크랩으로부터 코발트와 리튬을 회수하기위해 물리적 전처리, 침출, 용매추출 및 회수실험을 행하였다. 실험재료로 제조공정에서 발생되는 코발트계 양극스크랩을 사용하여 단위공정별 최적조건을 구하였다. 물리적전처리 최적조건은 온도 $500{\sim}550^{\circ}C$, 파쇄날 회전속도 1000rpm이었으며, 침출 최적조건은 300rpm, 2M $H_2SO_4$, 2.5M $H_2O_2$, $95^{\circ}C$이었다. D2EHPA(bis(2-ethylhexyl) phosphoric acid) 와 PC88A를 각각 알루미늄과 코발트의 추출제로 사용하여 분리.정제하였으며, 코발트는 염기성시약을 사용하여 $Co(OH)_2$로, 리튬은 탄산나트륨 및 LiOH를 사용하여 탄산리튬($LiCO_3$)으로 회수하였다. $Co(OH)_2$는 열처리를 하여 삼산화코발트($Co_3O_4$)로 만들고 분쇄기를 사용하여 10 ${\mu}m$정도의 입자를 만들었다. 최적조건에서 코발트와 리튬 회수율은 99%이상, 리튬회수율은 99%이상이었으며, 삼산화코발트의 순도는 99.98%이상이었다.

용매 추출법에 의한 폐수중 6가크롬의 원자흡수 분광분석에 관한 연구 (Studies on Atomic Absorption Spectrophotometric Analysis of Hexavalent Chromium in Waste Water by Solvent Extraction)

  • 김응표;김영상
    • 대한화학회지
    • /
    • 제30권5호
    • /
    • pp.423-432
    • /
    • 1986
  • 폐수 중의 6가크롬을 음이온 교환체인 aliquat-336(tri-caprylmethyl ammonium chloride)으로 이온쌍을 형성시켜 유기용매인 p-xylene으로 추출하여 원자흡수분광도법으로 정량하는 방법에 대하여 조사 검토하였다. Toluene을 용매로 사용하여 유기물을 제거한 폐수 100ml를 취하여 염산으로 pH 0.5 되게 산성화시킨 다음 aliquat-336을 0.01M되게 녹인 p-xylene 20ml로 6가크롬을 추출하였다. 표준물첨가법에 의해 air-acetylene 불꽃에서 용매중에 추출된 6가크롬을 정량하였다. Al(III), Fe(III), Cr(III)이온들은 6가크롬의 추출 및 흡광도 측정에 방해 하지 않았으며, Fe(III)이온이 6가크롬을 3가크롬으로 환원시키기 때문이다. 또한 유기물이 존재하면 6가크롬의 흡광도를 감소시키므로 이런 방해유기물을 toluene으로 추출 제거하였다. 최적 조건으로 분석한 결과는 96%이상의 회수율을 보여 주었고 이는 미량 분석에서 정확한 방법이라 할 수 있고, 상대평균편차가 3.95%로서 재현성도 비교적 좋았다.

  • PDF

추출크로마토그래피와 유도결합플라스마 원자방출분광법을 이용한 이산화우라늄분말 중 미량금속불순물 분석 (Determination of the Trace Elements in $UO_2$ Powder by ICP-AES Directyl Coupled with Extraction Chromatography)

  • 최광순;이창헌;표형열;한선호;서무열;엄태윤;이계호
    • 대한화학회지
    • /
    • 제37권9호
    • /
    • pp.813-819
    • /
    • 1993
  • $UO_2$ 분말에 미량 함유되어 있는 금속불순물들을 신속하게 정량하고 분석과정에서 발생되는 폐액의 양을 줄이기 위하여, 우라늄용액으로부터 미량금속불순물들을 분리함과 동시에 ICP-AES로 분석할 수 있는 장치를 구성하였다. 미량금속불순물들을 분리하기 위하여, 폴리에틸렌으로 제작한 분리컬럼(내경 : 0.7cm, 길이 : 7 cm)에 TBP(tri-n-butyl phosphate)를 입힌 테프론 분말(약 $330\;{\mu}m$)을 충진하고, 분리컬럼의 출구를 ICP-AES의 시료주입구에 연결시켰다. $UO_2$ 분말에 미량 함유되어 있는 몰리브덴을 비롯한 11개 원소를 분리와 동시에 정량할 수 있었으며, 이들 원소들에 대한 회수율은 용매추출법에서와 거의 동일한 $91{\sim}110%$로서 핵연료 제조공정의 품질관리에 적용이 가능하였다.

  • PDF

고기능성 쌀단백질 소재 개발 연구 (A study on the development of high functional food protein ingredient from rice bran)

  • 이의석;김기종;김재현;홍순택
    • 농업과학연구
    • /
    • 제37권1호
    • /
    • pp.61-68
    • /
    • 2010
  • Rice bran proteins from different cultivars(Youngan, Sindongjin, Suwon 511) were extracted with Xylanase using orthogonal analysis method and their functional properties were investigated. The optimum extraction conditions, based on protein content in the extract found to be at 1 wt% xylanase, pH 7 and 50:1, solvent to rice bran ratio(v/w %). Nitrogen solubility indices(NSI) of rice bran protein concentrates were shown a minimum value at pH 4 ranged 2~23%, varied with different cultivars and a maximum (NSI${\geq}$90% for all cultivars) at pH 10. As for water adsorption and fat adsorption capacity, rice bran protein concentrates were shown to be better than Na-caseinate and isolated soy protein, respectively. Emulsifying activities were observed high in order of Na-caseinate>Youngan rice bran protein>Shindongjin rice bran protein>Suwon 511 rice bran protein>isolated soy protein. In general, the surface tension of rice bran protein solution($10^{-3}$ wt%, 5 mM bis-tris, pH 7) was increased with increasing concentrations and found a minimum value near pI. On heating, it was decreased slightly with increasing temperatures up to $70^{\circ}C$ and then increased above $80^{\circ}C$. Addition of sodium chloride was made the surface tension decrease. In conclusion, with Xylanase, rice bran protein concentrate can be successfully extracted from the rice bran of different cultivars and the Youngan rice bran protein was thought to have best functionality among rice cultivars tested. It might be used as a milk protein substitute.