• Title/Summary/Keyword: external magnetic field

Search Result 449, Processing Time 0.025 seconds

THE EFFECT OF DUST PARTICLES ON ION ACOUSTIC SOLITARY WAVES IN A DUSTY PLASMA

  • Choi, Cheong-Rim;Lee, Dae-Young;Kim, Yong-Gi
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.3
    • /
    • pp.201-208
    • /
    • 2004
  • In this paper we have examined the effect of dust charge density on nonlinear ion acoustic solitary wave which propagates obliquely with respect to the external magnetic field in a dusty plasma. For the dusty charge density below a critical value, the Sagdeev potential $\Psi1(n)$ has a singular point in the region n < 1, where n is the ion number density divided by its equilibrium number density. If there exists a dust charge density over the critical value, the Sagdeev potential becomes a finite function in the region n < 1, which means that there may exist the rarefactive ion acoustic solitary wave. By expanding the Sagdeev potential in the small amplitude limit up to on4 near n=1, we find the solution of ion acoustic solitary wave. Therefore we suggest that the dust charge density plays an important role in generating the rarefactive solitary wave.

Material Characterization of MR Fluids at High Frequencies (고주파 영역에서의 MR 유체 특성연구)

  • Park, Kyoung-Mi;Kim, Jae-Hwan;Choi, Seung-Bok;Kim, Kyung-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.210-215
    • /
    • 2002
  • MR(Magnetorheogical) fluid composed of fine iron powders dispersed in silicon oil is utilized to many smart structures and devices because of its significant rheological property change by the application of an external magnetic field. When we deal with the shock wave attenuation of warship structures, we should be able to characterize the high frequency behavior of MR fluids. So far, however, many efforts have been focused on the material characterization of MR fluids at low frequencies below 100Hz. In this paper, the MR fluid property characterization at high frequency region is performed. An experimental setup based on wave transmission technique is made and the storage modulus as well as the loss modulus of MR fluids are found from the measured data of speed sound and attenuation. Details of the experiment are addressed and the obtained storage and loss moduli are addressed at $50kHz{\sim}100kHz$.

  • PDF

Charicteristics of HF 10-cm Type Grid Ion Source for Inert and Chemically Reactive Gases.

  • Chol, W.K;Koh, S.K;Jang, H.G;Jung, H.J;Kondranin, S.G.;Kralkina, E.A.;Bougrov, G.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1996.02a
    • /
    • pp.102-102
    • /
    • 1996
  • This paper represents a new type low power High Frequency technological ion source (HF TIS) for ion - beam processing: the surface modification of materials, cleaning of surface, sputtering, coating of thin films, and polishing. The operational principle of HF TIS is based on the excitation of electrostatic waves in plasma located in the external magnetic field. Low power HF TIS with diameter 92 rom gives the opportunity to obtain beams of inert and chemically reactive gases with currents range from 5 to 150 mA (current density $0.015\;~\;3.5\;mA/\textrm{m}^2$) and ion beam energy 100 ~ 2500 eV at a HF power level 10 ~ 150 W. Three grid concave type ion optical system (IOS) is used for extraction and formation ofion beam.n beam.

  • PDF

Flux Pinning in $MgB_2$ Film with Columnar Grains (기둥형 결정립 구조를 지닌 $MgB_2$ 박막에서 자속고정 현상)

  • Kim, D.H.;Kim, H.Y.;Hwang, T.J.;Lee, S.H.;Seong, W.K.;Kang, W.N.
    • Progress in Superconductivity
    • /
    • v.9 no.2
    • /
    • pp.173-176
    • /
    • 2008
  • [ $MgB_2$ ] films grown by hybrid physical chemical vapor deposition under appropriate growth conditions commonly exhibit columnar grain structure. The grain boundaries between adjacent columnar grains have been reported to be good flux pinning centers. In this work, we measured the angular dependence of critical current density ($J_c$) and observed the enhanced flux pinning when an external magnetic field was aligned parallel to the columnar direction. This $J_c$ was almost comparable to the $J_c$ for intrinsic pinning case up to 1 T at low temperatures, indicating that grain boundary pinning is very effective. At high fields, however, $J_c$ decreased rapidly resulting from the fact that the density of flux pinning centers provided by grain boundaries was outnumbered by the flux density.

  • PDF

Comparison of the Characteristics of Cu-Sn and Ni Pre-Plated Frames Prepared by Electro-Plating (전기도금된 Cu-Sn과 Ni preplated frame의 특성 비교)

  • Lee, D.H.;Jang, T.S.;Hong, S.S.;Lee, J.W.;Yang, H.W.;Hahn, B.K.
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.6
    • /
    • pp.276-281
    • /
    • 2006
  • In order to improve the performance of PPFs (Pre-Plated Frames), a PPF that employed a Cu-Sn alloy instead of conventionally used Ni was developed and then its properties were investigated. It was found that the electoplated Cu-Sn alloy layer was a mixture of uniformly distributed fine crystallites, resulting In better wettability and crack resistance than those of Ni PPF. Moreover, as in Cu/Ni/Pd/Au PPF, migration of copper atoms from the base metal to the top of the Cu/Cu-Sn/Pd/Au PPF surface was not found although the Cu-Sn layer itself contained considerable amount of copper. It was expected that, by using the newly developed Cu-Sn PPF, any possible heat generation and signal interrupt caused by an external electro-magnetic field could be reduced because the Cu-Sn layer was paramagnetic, i.e., nonmagnetic.

Nonuniformity Correction Scheme Based on 3-dimensional Visualization of MRI Images (MRI 영상의 3차원 가시화를 통한 영상 불균일성 보정 기법)

  • Kim, Hyoung-Jin;Seo, Kwang-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.948-958
    • /
    • 2010
  • Human body signals collected by the MRI system are very weak, such that they may be easily affected by either external noise or system instability while being imaged. Therefore, this paper analyzes the nonuniformity caused by a design of the RF receiving coil in a low-magnetic-field MRI system, and proposes an efficient method to improve the image uniformity. In this paper, a method for acquiring 3D bias volume data by using phantom data among various methods for correcting such nonuniformity in MRI image is proposed, such that it is possible to correct various-sized images. It is shown by simulations that images obtained by various imaging methods can be effectively corrected using single bias data.

The a.c. losses in (Bi,Pb)2Sr2Ca2Cu3Ox silver-sheathed superconducting tapes (Bi-2223 고온 초전도 선재의 교류손실에 관한 연구)

  • Kang, Hyoung-Ku;Chu, Yong;Lee, Chan-Joo;Ko, Tae-Kuk;Nah, Wan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.822-824
    • /
    • 2000
  • To apply HTS to AC devices, it is necessary that study theoretically and experimentally to analyze the AC losses. It should be investigated the theoretical mechanisms precede the actual experiments. Because the AC losses cause some complicated troubles in AC machines, we can design the machines properly. In this study, firstly we analyze the basic cause of AC losses by investigating the several loss factors, secondly measure the AC losses of HTS by using Magnetization. Technique and this results show that AC losses of HTS is tenuous than those of general materials used in power system. Consequently we can compare the actual results with the theoretical results. And we find that AC losses of HTS are related to the amplitude of external magnetic field and the frequency. Through this study, we find that it is possible to apply the results by Magnetization. Technique to the AC power system, to the design of AC machine, to design of HTS proper to the foretold AC losses.

  • PDF

Corrosion Quantification of Reinforcing Bar in Concrete Using Micro Computer Tomography (Micro-CT 활용 콘크리트 내 철근 부식 정량을 위한 실험적 연구)

  • Jang, In-Dong;Yi, Chong-Ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.252-253
    • /
    • 2019
  • Corrosion of rebars in reinforced concrete structures is a major factor that shortens the life of the structure. As corrosion progresses, the adhesion between the concrete tissues and the rebar decreases and the cracks in the concrete due to the expansion of the oxide intensify. Although it is necessary to measure corrosion behavior of rebars inside the concrete to measure degradation of structures due to rebar corrosion, no studies have been conducted to measure corrosion of rebars in In-situ state. In this study, corrosion of rebars in reinforced concrete specimens was attempted to be quantified using micro-computer tomography. Since corrosion of concrete takes several months per 10mm of cover, accelerated corrosion techniques were applied. Accelerated corrosion on the specimen was conducted by applying a 10 V magnetic field to the buried rebar and external electrodes with the specimen submerged in a 10% calcium chloride solution. The experiment found that within two weeks, more than 40% of rebar reduction occurred, and the cracks in the radial cracks occurred through the concrete structure, leading to the transfer of the oxide produced through the cracks to the surface of the specimen.

  • PDF

A Laterally-Driven Bistable Electromagnetic Microrelay

  • Ko, Jong-Soo;Lee, Min-Gon;Han, Jeong-Sam;Go, Jeung-Sang;Shin, Bo-Sung;Lee, Dae-Sik
    • ETRI Journal
    • /
    • v.28 no.3
    • /
    • pp.389-392
    • /
    • 2006
  • In this letter, a laterally-driven bistable electromagnetic microrelay is designed, fabricated, and tested. The proposed microrelay consists of a pair of arch-shaped leaf springs, a shuttle, and a contact bar made from silicon, low temperature oxide (LTO), and gold composite materials. Silicon-on-insulator wafers are used for electrical isolation and releasing of the moving microstructures. The high-aspect-ratio microstructures are fabricated using a deep reactive ion etching (DRIE) process. The tandem-typed leaf springs with a silicon/gold composite layer enhance the mechanical performances while reducing the electrical resistance. A permanent magnet is attached at the bottom of the silicon substrate, resulting in the generation of an external magnetic field in the direction vertical to the surface of the silicon substrate. The leaf springs show bistable characteristics. The resistance of the pair of leaf springs was $7.5\;{\Omega}$, and the contact resistance was $7.7\;{\Omega}$. The relay was operated at ${\pm}0.12\;V$.

  • PDF

Characteristics Analysis of a Forward Converter by Finite Element Method and State Variables Equation (유한요소법과 상태방정식을 이용한 포워드 컨버터의 동작 특성 해석)

  • Park, Seong-Jin;Gwon, Byeong-Il;Park, Seung-Chan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.467-475
    • /
    • 1999
  • This paper presents an analysis method of a forward converter, using both the finite element method considering the external circuit and a state variables equation. The converter operates at 50kHz and its one period is divided into two modes for the simplicity of the analysis. In the first mode, the switching transistor turns on and an input power is transferred into the load by the electromagnetic conversion action of a ferrite transformer. In the second mode, the switching transistor turns off and the stored energy in an inductor is delivered to the load, and the transformer core is demagnetized by the reset winding current. In this paper, time-stepping finite element method taking into account the on-state electrical circuit of the converter in used to analyze both the electrical circuit and electromagnetic field of the magnetic device during the first mode and the demagnetization period of the transformer core. Then a state variables equation for the circuit which the inductor current flows is constituted and solved during the second mode. As a result, the simulation results have been good agreement with the results obtained form experiment.

  • PDF