• Title/Summary/Keyword: external magnetic field

Search Result 449, Processing Time 0.028 seconds

Measurement of Monodisperse Particle Charging in Unmagnetized and Magnetized Plasmas (자화된 플라즈마 내에서의 단분산 입자의 하전량 특정)

  • 한장식;안강호;김곤호
    • Journal of the Semiconductor & Display Technology
    • /
    • v.1 no.1
    • /
    • pp.35-40
    • /
    • 2002
  • Understanding of charging properties of a small particle is necessary to control the particle contamination and to improve productivity of the electronic device in the plasma aided semiconductor manufacturing processes. In this study, the effects of both magnetic field and particle size on the charging properties are experimentally investigated in collisional dusty plasmas. The experiments carried out in the system consisted of a monodisperse particle generation system, a DC magnetized plasma generation system and a charge measurement system. The plasma chamber is made of cross-shape Pyrex surrounded by magnetic bucket (composed of 12 permanent magnetic bar) to confine the plasma. DC magnetic field up to 250G are applied to the plasma zone by external magnetic coil. Previous work shows the charging effect clearly increase with increasing the size of the particle and plasma density, as it was expected.

  • PDF

Calculation of DC Characteristics of Stacked BSCCO Wires under Variable External Magnetic field (수치해석을 이용한 BSCCO 적층 선제들의 외부자장 변화에 따른 DC 통전 특성 계산)

  • Lim, Hyoung-Woo;Kang, Myung-Hun;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.53-55
    • /
    • 2007
  • This paper has presented the numerical calculation of fundamental characteristics of the HTS wire by using commercial software. Numerical calculation of the HTS wire's characteristics is able to reduce the time and effort which need to be exerted to obtain hose values experimentally. Results of numerical calculation, such as, critical current of he single and the multi-slacked wire under external magnetic field, were compared with that of experimental results.

  • PDF

Magnetization Frequency Dependence of Enhanced Inductively Coupled Plasma and Etching Characteristics (자화주파수에 따른 플라즈마 및 산화막식각특성에 관한 연구)

  • 김진우;조수범;박세근;오범환
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.37-40
    • /
    • 2001
  • The semiconductor's design rule becomes more stringent, hence the silicon-dioxide etching technique is important issue. In this work we compared the etching characteristics of different three types of Plasma source, Normal ICP, magnetized ICP and E-IC $P^{TM}$. The E-IC $P^{TM}$ source shows higher etch rate at lower pressure and this is advantageous for the fine pattern process. The etching characteristics were varied with external magnetic field frequency at I-lCP and this is examined with Nanospe $c^{TM}$ and SEM. We designed Langmuir probe system for time resolved diagnosis. ion density of E-ICP is varying periodically with the applied external magnetic field frequencyquency

  • PDF

Static measurement of magnetostriction of FeCoGe/phenol composites (FeCoGe/페놀 복합체의 정적 자기변형 측정)

  • Park, K.I.;Na, S.M.;Shin, K.H.;Lim, S.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.577-580
    • /
    • 2003
  • The magnetostriction of FeCoGe/phenol composites, which is one of the magnetostrictive materials, measured at the external magnetic field. The measurement was carried out using the electrical-resistance strain gage, the wheaten's Bridge for eliminating the unnecessary voltage, and the lock-in-amp for signal amplification and noise filtering. When the external magnetic field was applied in the longitudinal the samples, the maximum strain of 120ppm was taken with regard to the 10wt.% phenol composite. This results indicate that the FeCoGe/phenol composites can be useful as an actuator because it has larger stain than the other solid state actuators such as piezo electric materials.

  • PDF

Analysis of I-V Characteristics in the Multi-channel Superconducting Vortex Flow Transistor (다채널 고온 초전도 볼텍스 유동 트랜지스터의 I-V 특성 해석)

  • 고석철;강형곤;임성훈;최효상;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.931-937
    • /
    • 2003
  • The principle of the superconducting vortex flow transistor (SVFT) is based on control of the Abrikosov vortex flowing along a channel. The induced voltage is controlled by a bias current and a control current, instead of external magnetic field. The device is composed of parallel weak links with a nearby current control line. We explained the process to get an I-V characteristic equation and described the method to induce the external and internal magnetic field by the Biot-Savarts law in this paper. The equation can be used to predict the I-V curves for fabricated device. From the equation we demonstrated that the current-voltage characteristics were changed with input parameters. I-V characteristics were simulated to analyze a SVFT with multi-channel by a computer program.

The Performance Analysis of Direct Current Electromagnetic Propulsion in Seawater

  • Kong, Yeong-Kyung;Park, Tai-In;Kim, Yun-Sik;Noh, Chang-Joo
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.38-44
    • /
    • 1993
  • Electromagnetic seawater thrusters may be classified into four general categories : internal duct dc, external field dc, internal peristaltic ac, and external peristaltic ac. Internal duct dc thrusters offer the advantages of low magnetic field leakage, simple construction, and potentially high reliability. The most efficient internal duct configuration consists of converging inlet nozzle and a straight discharge duct. Ideal efficiency calculations based on the one-dimensional Bernoulli equation show that thrusters should be designed with large cross-sectional areas and operate at low discharge velocities. In practice, this may be accomplished by using multiple thruster ducts. Conductivity enhancement, high magnetic fields, and long electrodes will also improve efficiency.

  • PDF

Young's Modulus Measurement of FeCoGe/phenol Composites (FeCoGe/페놀 복합체의 영률 측정)

  • Park, K.I.;Kim, H.G.;Shin, K.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.107-109
    • /
    • 2003
  • The magnetostriction of FeCoGe/phenol composites is measured under the external magnetic field. A few Measurement are carried out by using the electrical-resistance strain gage, the Wheaton Bridge for eliminating the unnecessary voltage, the lock-in-amplifier for the signal amplification and noise filtering. When the external magnetic field is applied to the longitudinal direction against those samples which is the 10wt.% phenol in composites, the theoretical maximum strain of 120ppm is obtained. According to the larger strain than that of others solid state actuators and piezoelectric actuators. FeCoGe/phenol composites could be useful as an actuator.

  • PDF

Numerical Analysis of The Coupling Loss in AC Superconducting Wires (교류용 초전도선의 결합손실해석)

  • Sim, Jung-Wook;Cha, Guee-Soo;Lee, Ji-Kwang;Choi, Kyeong-Dal;Han, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.291-293
    • /
    • 1997
  • The external magnetic field which is applied to the superconducting wire generates coupling loss. Analytical method has been used for the calculation of the coupling loss. This paper calculates the coupling loss that is generated in the matrix by the external magnetic field. Two-dimensional Finite Element Method has been used for the calculation.

  • PDF

Effects of the insulation thickness on the magnetization loss of the multi-stacked YBCO coated conductor (절연거리 변화에 따른 적층된 YBCO 도체의 자화손실 변화)

  • Lim, Hyoung-Woo;Lee, Hee-Joon;Cha, Guee-Soo;Lee, Ji-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.95-97
    • /
    • 2005
  • Loss in the multi-stacked HTS wires are affected by a number of factor, such as, number of wires used in the stack, direction of external magnetic field and insulation thickness between the wire. This paper examines the effects of the insulation thickness on the magnetization loss of the multi-stacked YBCO coated conductor. Measurements of magnetization loss were performed using 4 different typo of multi-stacked wires and under various angle of external magnetic field. Test results show that loss density per unit volume increased for YBCO coated conductors when thickness of insulation increased. Loss density per unit volume decreased for YBCO coaled conductors when stacking number of tapes increased.

  • PDF

Magnetostriction and Young's Modulus Measurement of FeCoGeW/phenol Composites (FeCoGeW/페놀 복합체의 자왜 및 영률 측정)

  • Park, K.I.;Kim, H.G.;Shin, K.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.325-328
    • /
    • 2003
  • The magnetostriction of FeCoGeW/phenol composites is measured under the external magnetic field. A few Measurement are carried out by using the electrical-resistance strain gage, the Wheaton Bridge for eliminating the unnecessary voltage, the lock-in-amplifier for the signal amplification and noise filtering. When the external magnetic field is applied to the longitudinal direction against those samples which is the 10wt.% phenol in composites, the theoretical maximum strain of 120ppm is obtained. According to the larger strain than that of others solid state actuators and piezoelectric actuators. FeCoGeW/phenol composites could be useful as an actuator.

  • PDF