• Title/Summary/Keyword: external magnetic field

Search Result 449, Processing Time 0.029 seconds

Total AC Loss by simultaneously applied AC transport current and AC external magnetic field in BSCCO Tape

  • Park Myungjin;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.10-13
    • /
    • 2005
  • Transport current and magnetic field which is generated by transport current make AC current - AC mag-netic field condition(AC-AC condition) in AC power application system using HTS tape. Therefore, characteristics of AC loss under the AC-AC condition are necessary to estimate AC loss of power device with accuracy such as HTS transformer. In this paper, we researched transport current loss, magnetization loss by perpendicular magnetic field and total loss which is represented as summation of both losses under the AC-AC condition in single HTS tape. As a result, magnetization loss showed increasing behavior under 65mT and decreasing behavior upper 65mT by influence of transport current. Transport current loss was increased continuously through out whole measurement ranges in the AC-AC condition. Total loss in HTS tape was dominated entirely by magnetization loss.

Properties of Filter type Magnetoimpedance Sensor (필터타입으로 구성한 자기임피던스센서의 특성)

  • SaGong, Geon;Kim, Young-Hak;Shin, Kwang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.337-340
    • /
    • 2004
  • To develop the highly sensitive Magneto-Impedance sensor, the amorphous ribbon was micro-processed to meander type sensor pattern and the filter circuit was constructed with this pattern. Its external magnetic field dependence of impedance and the output properties of the filter circuit were investigated. The impedance of the pattern had a peak value at the magnetic field of 10 Oe and its changing ratio was about 280%. The impedance change per unit magnetic field was about 36%, in which the output with high sensitivity and linearity could be obtained. The output sensitivity was about 7%/Oe at bias field of 6 Oe..

  • PDF

Measurement and Analysis of the Flux Profiles of the Coated Conductors using Magneto-optical Image and Scanning Hall Probe (Coated conductor에서 magneto-optical image와 scanning hall probe를 이용한 flux profile의 측정 및 분석)

  • Lee, H.Y.;Kwak, K.S.;Rhyee, J.K.;Yoo, J.;Youm, D.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.128-134
    • /
    • 2010
  • The magnetic flux profiles in SmBCO and YBCO coated conductors(CC) in the presence of the external field were comparatively investigated by magneto-optic image and scanning hall probe measurements. The current distributions calculated by using the inversion method from measured field profiles show that the decrease of current densities near the edges of SmBCO CC is more significant than those of YBCO CC. Through the comparison of the numerical analysis based on Kim's critical state model and the Brandt and Indenbom's solution, we found that this feature is related to their different field dependant properties of the critical current densities.

The Magnetic Field Dependence of the Confinement Potential due to the Interaction of Electron and Piezoelectric Phonon in GaAs Semiconducting Materials (구속 포텐셜의 전자-압전 포논 상호 작용에 따른 GaAs의 자기장 의존 특성)

  • Lee, Su-Ho;Kim, Hai-Jai;Joo, Seok-Min
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.149-154
    • /
    • 2018
  • We consider the system is subject to the linearly polarized oscillatory external field. We study the optical quantum transition Line shapes(QTLS) which show the absorption power and the quantum transition line widths(QTLW) of electron-piezoelectric phonon interacting system. We analyze the magnetic field dependence of the QTLS and the QTLW in various cases. In order to analysis the quantum transition, we compare the magnetic field dependence of the QTLW and the QTLS of two transition process, the intra-Landau level transition process and the inter-Landau level transition process.

Terahertz Characteristics of Hydroxygraphene Based on Microfluidic Technology

  • Boyan Zhang;Siyu Qian;Bo Peng;Bo Su;Zhuang Peng;Hailin Cui;Shengbo Zhang;Cunlin Zhang
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.463-470
    • /
    • 2023
  • Hydroxygraphene as a kind of functionalized graphene has important applications in composite, photoelectric and biological materials. In the present study, THz and microfluidic technologies were implemented to study the THz transmission characteristics of hydroxygraphene with different concentrations and residence times in magnetic and electric fields. The results show that the THz transmission intensity decreases with the increase in sample concentration and duration of an applied electric field, while it increases by staying longer in the magnetic field. The phenomenon is analyzed and explained in terms of hydrogen bond, conductivity and scattering characteristics. The results establish a foundation for future research on the THz absorption characteristics of liquid graphene based on microfluidic technology in different external environments. It also provides technical support for the application and development of graphene in THz devices.

Design and Fabrication of Digital 3-axis Magnetometer for Magnetic Signal from Warship (함정 자기신호 측정용 3-축 디지털 자기센서 설계 및 제작에 관한 연구)

  • Kim, Eunae;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.123-127
    • /
    • 2014
  • We developed a digital 3-axis flux-gate magnetometer for magnetic field signal measurement from warship during demagnetizing and degaussing processes. For the magnetometer design, we considered following points; the distance between magnetic field measurement station and magnetometer located under sea is about several 100 m, the magnetometer is exposed to magnetic field of ${\pm}1mT$ during demagnetizing process, and magnetometer is located under the sea about 30 m depth. To overcome long distance problem, magnetometer could be operated on wide input supply voltage range of 16~36 V using DC/DC converter, and for the data communication between the magnetometer and measurement station a RS422 serial interface was employed. To improve perming effect due to the ${\pm}1mT$ during demagnetizing process, magnetometer could be compensated external magnetic field up to ${\pm}1mT$ but magnetic field measuring rang is only ${\pm}100{\mu}T$. The perming effect was about ${\pm}2nT$ under ${\pm}1mT$ external magnetic field. The magnetometer was tested water vessel with air pressure up to 6 bar for the sea water pressure problems. Linearity of the magnetometer was better than 0.01 % in the measuring range of ${\pm}0.1mT$ and noise level was $30pT/\sqrt{Hz}$ at 1 Hz.

A COMPREHENSIVE VIEW OF LARGE-SCALE MAGNETIC FIELDS, WITH EMPHASIS ON THE GALACTIC MAGNETIC FIELD NEAR THE SUN

  • HEILES CARL
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.151-154
    • /
    • 1996
  • We examine the observations of large-scale magnetic fields in the Universe. We begin at the largest scale with clusters of galaxies and work our way down through galaxies and finally to the Milky Way. on which we concentrate in detail. We examine the observations of the Galactic magnetic field, and their interpretation, under the philosophy that the Galactic magnetic field is like that in other spiral galaxies. We use pulsar data. diffuse Galactic synchrotron emission, and starlight polarization data to discuss the Galaxy's global magnetic configuration and the uniform ($B_u$), random ($B_r$), and total ($B_t$) components of the field strength. We find disagreement among conclusions derived from the various data sets and argue that the pulsar data are not the best indicator for large-scale Galactic field. Near the Solar circle, we find that the azimuthal average of $B_t$ is 4.2$\mu$G and we adopt $B_u\~$2.2 and $B_r\~3.6{\mu}G$. $B_t$ is higher in spiral arms, reaching $\~5.9{\mu}G$. $B_t$ is higher for smaller $R_{Gal}$, reaching $\~8.0{\mu}G$ for $R_{Gal}$ = 4.0 kpc. The pattern of field lines is not concentric circles but spirals. The inclination of the magnetic spiral may be smaller than that of the Galaxy's spiral arms if our sample, which refers primarily to the interarm region near the Sun, is representative. However, it is not inconceivable that the local field lines follow the Galaxy's spiral pattern, as is observed in external galaxies.

  • PDF

Lorentz Force Density Distribution of a Current Carrying Superconducting Tape in a Perpendicular Magnetic Field

  • Yoo, J.;Kwak, K.;Rhee, J.;Park, C.;Youm, D.;Park, B.J.;Han, Y.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.13-16
    • /
    • 2010
  • The Lorentz force distribution of a high $T_c$ superconducting tape with increasing transport currents in magnetic field ($H_a$) was visualized. The external magnetic field was applied normally to the coated conductor tape surface after zero-field cooling, and the transport current ($I_a$) was increased stepwise from 0 to 90 % of the values of the critical current ($I_c$ ($H_a$)) at applied filed, Ha. The field distribution (H(x)) near the sample surface across the tape width (2w) was measured using the scanning Hall probe method. Applying an inversion to the measured field distribution, we obtained the underlying current distribution (J(x)), from which the magnetic induction, B(x) was calculated with Biot-Savart law. Then Lorentz force per unit length was calculated using F(x)=J(x)${\times}$B(x), which appears to be very inhomogeneous along the tape width due to the complicated distributions of J(x) and B(x).

A Study on the Fabrication and Electromagnetic Characteristics of High Tc Superconductor Using Pyrosis method for Electrical Equipment (열분해법에 의한 전력기기용 고온 초전도체의 합성 기술 및 전기 자기적 특성)

  • Lee, Sang-Heon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.10
    • /
    • pp.453-456
    • /
    • 2005
  • We have fabricated superconducting ceramics by chemical process. A high Tc superconducting with a nominal composition of YBaCuO was prepared by the pyrolysis method. The electromagnetic properties in YBaCuO superconductor was studied. In the measurement of current-voltage characteristics, a voltage across the superconducting sample was observed on applying an external magnetic field. The voltage increases with increase in applied magnetic flux, but it becomes constant at about 10$^{-2}$T. The voltage continues to appear the removal of the magnetic field. The appearance of the voltage is ascribed to the trapping of magnetic flux. Depending on the direction of applied magnetic flux less than 2.5$\times$10$^{-5}$ T, the voltage in the magnetized sample increases or decreases.

A Study on the Electric Characteristics of High Tc Superconductor (전력기기용 초전도의 전기적 특성)

  • Lee, Sang-Heon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.10
    • /
    • pp.481-484
    • /
    • 2006
  • The electric properties in YBCO superconductor was studied. In the measurement of current-voltage characteristics, a voltage across the superconducting sample was observed on applying an external magnetic field. The voltage increases with increase in applied magnetic flux, but it becomes constant at about $10^{-2}T$. The voltage continues to appear the removal of the magnetic field. The appearance of the voltage is ascribed to the trapping of magnetic flux. Depending on the direction of applied magnetic flux less than $2.5{\times}10^{-5}T$, the voltage in the magnetized sample increases or decreases.