• 제목/요약/키워드: external connection method

검색결과 105건 처리시간 0.028초

체결력을 고려한 내부 및 외부연결형 임플란트의 반복 하중에 대한 풀림 연구 (Loosening behavior of Internal and External Connection Dental Implants under Cyclic Loads Considering Pre-fastening Force)

  • 이용우;장용훈
    • Tribology and Lubricants
    • /
    • 제37권4호
    • /
    • pp.136-143
    • /
    • 2021
  • This paper presents the loosening behavior that occurs after the application of an external load to internal and external connection types of dental implants using the finite element method. We use fastening force between an abutment and a fixture to clamp the dental implant system; however, loosening and breakage may occur owing to cyclic external loads. In this study, we considered the initial fastening condition in the pre-load analysis and then investigated the change in stress and contact surface status when applying external loads. After the application of the initial fastening load, we verified that the internal connection-type model exhibited a relatively lower stress distribution than that of the external connection-type one. Moreover, we found that the former model showed a lower stress concentration after the application of the external load. In addition, after the application of this load, we found that the higher the shear load acting on the implant system, the higher the possibility of loosening. The study results showed the change in stress distribution and contact surface according to the connection type of the dental implants and the phenomenon of loosening by cyclic loads. We expect that the results of this study will be useful for the study of reliability and design of dental implant systems.

무도장 내후성 강교량의 Box Girder 내부볼트 연결부에 대한 외부전원식 정기방식효과에 관한 연구 (A study on the effect of the external electric type corrosion resistance for the bolt connection in weathering steel box girders.)

  • 박용걸;김헌태;백찬호;최정열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.988-993
    • /
    • 2004
  • This paper considers corrosion problems in the bolt connection of weathering steel box girder bridge using the external electric type corrosion resistance method which resisted to local corrosion in coated steel surface with contacted air. The weathering steel was created a rust itself in the passive state. but a coated box girder type was easily dew form could be made galvanic cell that accelerated corrosion. so that it was ruled by protection coat with some paint. Therefore, it needed that can be applied the external electric type corrosion resistance method in coated surface. As a result of the test of polarization amount had measured that the weathering steel was higher currents than the general steel by about $5\~10\%$. Therefore. an external electric type corrosion resistance method can be used to protect local corrosion in the coated bolt connection of weathering steel box girders effectively.

  • PDF

임플랜트 지대주에 따른 나사 풀림의 연구 (THE INFLUENCE OF IMPLANT FIXTURE-ABUTMENT CONNECTION DESIGN ON SCREW LOOSENING)

  • 문양숙;박상원;방몽숙;양홍서;박하옥
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.174-184
    • /
    • 2006
  • Purpose: Current trend in implant dentistry is changing from external connection to internal connection. To evaluate the splinting of external and internal connection implant on screw loosening, 2-units prosthesis was fabricated with BioPlant $System^(R)$ of external connection type and Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. Material and Method: Experimental group is classified into three groups. 1) $G_1-EE$: 2-units prosthesis was fabricated with two Bioplant $System^(R)$ of external connection type. 2) $G_1-EI$: 2-units prosthesis was fabricated with one BioPlant $System^(R)$ of external connection type and one Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. 3) $G_1-II$: 2-units prosthesis was fabricated with two Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. In fabricating 2-units prosthesis, two hexed abutments are recommended when two implants are installed parallel, otherwise one hexed abutment is used on major occlusal force area and one nonhexed abutment is used on the other area. Since it is rare to find two implants being parallel, it is hard to fabricate prosthesis with passive adaptation using two hexed abutments. It is much more difficult to acquire passive adaptation when using hex abutment compared to nonhex abutment. To evaluate the influence of hexed and nonhexed abutment on screw loosening, 2-units prosthesis was fabricated with hexed and nonhexed abutment. Experimental group is classified into three groups. 1) $G_2-HH$: 2-units prosthesis was fabricated with two hexed abutments. 2) $G_2-HN$: 2-units prosthesis was fabricated with one hexed abutment and one nonhexed abutment. 3) $G_2-NN$: 2-units prosthesis was fabricated with two nonhexed abutments. Result: The results of comparing the detorque value after loading on a each prosthesis periodically are as follows. 1. In splinting group of external and internal connection implant, $G_1-II$ group demonstrated the biggest detorque value, followed by $G_1-EI$ group and $G_1-EE$ group. 2. There is no notable significance between external connection implant of $G_1-EI$ group and $G_1-EE$ group and also no significance between internal connection implant of $G_1-EI$ group and $G_1-II$ group. 3. $G_2-HH$ group showed higher detorque value than $G_2-HN\;and\;G_2-NN$ group. From the results, we can concluded that using both external connection and internal connection implant together is clinically acceptable and in order to acquire a good passive adaptation in fabricating 2-units implant prosthesis we can use two nonhexed abutments.

Seismic performance of beam-to- SST column connection with external diaphragm

  • Rong, Bin;Yin, Shuhao;Zhang, Ruoyu;Wang, Lei;Yang, Ziheng;Li, Hongtao;Wan, Wenyu
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.633-647
    • /
    • 2020
  • This paper aims to study the seismic performance of external diaphragm connection between SST (square steel tube) column and H-shaped beam through experimental and analytical study involving finite element (FE) method and theoretical analysis. In the experimental study, three external diaphragm connection specimens with weak panel zone were tested under axial pressure on the top of the column and antisymmetric cyclic loads at the beam end to investigate the seismic performance of the panel zone. The hysteretic behavior, failure mode, stiffness and ductility of the specimens were discussed. Key point to be explored was the influence of the thickness of the steel tube flange on the shear capacity of the specimens. In the analytical study, three simplified FE models were developed to simulate the seismic behavior of the specimens for further analysis on the influence of steel tube flange. Finally, four existing calculation formulas for the shear capacity of the external diaphragm connection were evaluated through comparisons with the results of experiments and FE analysis, and application suggestions were put forward.

Experimental and theoretical studies on SHS column connection with external stiffening ring under static tension load

  • Rong, Bin;You, Guangchao;Zhang, Ruoyu;Ma, Xu;Quan, Xinxin
    • Steel and Composite Structures
    • /
    • 제28권2호
    • /
    • pp.167-177
    • /
    • 2018
  • In order to investigate mechanical properties in the core area of Square Hollow Section(SHS) column connection with external stiffening ring, four specimens were tested under the static tension load. The failure modes, load-displacement curves and strain distribution were analyzed to study the mechanical properties and the load transfer mechanism of the core area of connections. The connections behave good ductility and load-bearing capacity under the static tension load. Parametric analysis was also conducted, in which the thickness of steel tube, extended width and thickness of the stiffening ring were considered as the parameters to investigate the effects on mechanical properties of the connections. Based on the experimental results, an analytical method for the bearing capacity of connection with external stiffening ring under the static tension load was proposed. The theoretical results and the experimental results are in good agreement, which indicates that the theoretical calculation method of the bearing capacity is advisable.

Failure mechanisms of externally prestressed composite beams with partial shear connection

  • Dall'Asta, A.;Dezi, L.;Leoni, G.
    • Steel and Composite Structures
    • /
    • 제2권5호
    • /
    • pp.315-330
    • /
    • 2002
  • This paper proposes a model for analysing the non-linear behaviour of steel concrete composite beams prestressed by external slipping cables, taking into account the deformability of the interface shear connection. By assuming a suitable admissible displacement field for the composite beam, the balance condition is obtained by the virtual work principle. The solution is numerically achieved by approximating the unknown displacement functions as series of shape functions according to the Ritz method. The model is applied to real cases by showing the consequences of different connection levels between the concrete slab and the steel beam. Particular attention is focused on the limited ductility of the shear connection that may be the cause of premature failure of the composite girder.

구강내에서 임플랜트 지대주 형성 시 내부연결방식과 외부연결방식간의 열전달 효과 비교 (THE COMPARATIVE STUDY OF THERMAL INDUCTIVE EFFECT BETWEEN INTERNAL CONNECTION AND EXTERNAL CONNECTION IMPLANT IN ABUTMENT PREPARATION)

  • 허중보;고석민
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.60-70
    • /
    • 2007
  • Statement of problem: The cement-type abutment would be needed for the reduction of its body in order to correct the axis and to assure occlusal clearance. In the case of intraoral preparation, there is a potential risk that generated heat could be transmitted into the bone-implant interface, where it can cause deterioration of tissues around the implant and failed osseointegration. Purpose: The purpose of this study was to assess the difference of the heat transmitting effect on external and internal connection implant types under various conditions. Material and method: For evaluating the effects of alternating temperature, the thermocoupling wires were attached on 3 areas of the implant fixture surface corresponding to the cervical, middle, and apex. The abutments were removed 1mm in depth horizontally with diamond burs and were polished for 30 seconds at low speed with silicone points using pressure as applied in routine clinical practice. Obtained data were analyzed using Mann-Whitney rank-sum test and Wilcoxon / Kruskal-Wallis Tests. Result: Increased temperature on bone-implant interface was evident without air-water spray coolant both at high speed reduction and low speed polishing (p<.05). But, the difference between connection types was not shown. Conclusion: The reduction procedure of abutment without using proper coolant leads to serious damage of oral tissues around the implant irrespective of external and internal connection type.

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms

  • Lee, Seong-Hui;Yang, Il-Seung;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제10권3호
    • /
    • pp.261-279
    • /
    • 2010
  • Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.

내표면 온도차 비율(TDRi) 분석을 통한 현대 신한옥 외벽 모서리 부위 단열성능 평가 (Thermal Performance Evaluation at corners of the External wall of Modern New Han-oks using Temperature Difference Ratio inside)

  • 이주엽;송민정;이태강;김선우;천득염
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.103-112
    • /
    • 2016
  • Recently, many New Han-oks have been constructing in all over the country to popularize as a type of green house. But, achievement of thermal performance of external wall is still the very important issue to become popular. Purpose: The purpose of this study is to verify the thermal performance level of modern New Han-ok through Temperature Difference Ratio inside(TDRi) analysis at corners of the external wall in Han-ok. Method: To achieve this goal, measurements were carried out in 12 Han-oks(experimental mock-up(1), exhibition Han-ok(1), happy village Han-oks(10)) by taking a infra-red thermography using thermal video system. Following are analysis items about connection joint between wall and wood columns of external wall conditions; the part between external wall and external wall(2D), external wall and ceiling(or floor)(2D), 2 external walls and ceiling(or floor)(3D) and so on. Result: It was analyzed that the probability of condensation at most of connection joint appear high and TDRi of 3D corners is higher than that of 2D corners in general. It means that the development of construction techniques about connection joint between wood columns and external wall is still required. The results of this study may be used to improve the construction technology of new Han-ok and as a basis for the specifying the desired thermal comfort environment of dwelling.

유사동적실험에 의한 외부접합형 카고메 트러스 제진장치가 설치된 RC 라멘조 공동주택의 내진성능 평가 (Seismic Performance Evaluation of R/C Frame Apartment Strengthened with Kagome Truss Damper External Connection Method by Pseudo Dynamic Test)

  • 허무원;천영수;황재승;이강석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.23-34
    • /
    • 2015
  • 최근 새로운 3차원 와이어 다공질 형태의 카고메 트러스 이력형 제진장치가 개발되어, 건축물의 내진성능 개선을 위한 제진장치로서의 적용가능성이 재료실험을 통하여 검증되었다. 본 연구에서는 카고메 트러스 이력형 제진장치를 RC 라멘조 공동주택에 외부접합 한 새로운제진구조시스템을 제안하였다. 카고메 외부접합형 제진구조시스템은 대상건물, 카고메 제진장치, 지지구조물로 구성되어 있으며, 기존 층간에 설치된 제진시스템과 달리 외부 지지 구조물과 대상 건축물의 상호작용을 이용하여 제진장치가 지진 에너지를 흡수하는 시스템이다. 본 연구에서 제안한 카고메 외부접합형 제진공법의 유효성을 검증 할 목적으로 LH공사 시범적용용 RC 라멘조 20층 공동주택의 골조를 대상으로 유사동적실험을 실시하여 내진성능 개선효과를 검토하였다. 그 결과, 국내에서 발생 가능한 지진규모 (200gal)에서 비보강 골조는 중규모의 지진피해가 예상되었지만, 카고메 외부접합형 제진보강법으로 보강한 골조는 경미한 지진피해가 예상되었으며, 대규모 지진(300gal)을 상정한 경우에도 중규모 이하의 지진피해가 예상되어 본 연구에서 개발한 카고메 제진보강법의 내진성능 개선 효과의 유효성이 검증되었다고 사료된다.