• 제목/요약/키워드: external clamp

검색결과 65건 처리시간 0.031초

원전용 안전등급 밸브의 용접부 누설 클램핑 현장보수 기술 검토 (Preliminary Review of On-Site Clamping Repair Technology for Welding Part Leakage of Safety Related Valve in the Nuclear Power Plant)

  • 김기홍;김기수;정환석;장무경
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.52-59
    • /
    • 2023
  • The welding part of the valve needs immediate action when leakage occurs due to cracks or damage. In order to repair leakage of the welding part, the valve must be separated from the pipe or replaced with a new valve. However, it is difficult to remove the valve while operating the power plant. This study presents a method to remove leakage by precisely processing the gap between the clamp and the incision part within 0.1mm while installed in the pipe system. If the external leakage is removed using a clamp on the welding part without removing the valve during operation, the time and cost required for maintenance can be reduced.

비선형 특성을 갖는 파이프 연결부에 대한 안전성 (A Safety about the Pipe Joint with Nonlinear Property)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제6권2호
    • /
    • pp.3-8
    • /
    • 2007
  • Nonlinear property and contact matter are analyzed about the pipe applied with internal pressure through this study. The weakest part and its safety can be examined. Maximum equivalent stress is shown at the contact surface between bolt and nut. The value of contact stress with the pressure of 12MPa is increased 1.4 times as large as that with no pressure. The maximum contact pressure is shown at the clamp corner of the external surface on pipe. The value of contact pressure with the pressure of 12MPa is increased 1.4 times as large as that with no pressure. The radial deformation with no pressure is also increased greatly at the middle part of internal surface on pipe. But this maximum deformation on pipe with the pressure of 12MPa is shown at the part far away the support of pipe. This value is increased 5.7 times as large as that value with no pressure. As contact status, the sticking occurs most at the external surface of pipe. It also tends to occur at the contact surface between bolt and nut. At the external surface of pipe, the sticking in case of the pressure of 12MPa occurs more than that in case of no pressure.

  • PDF

족관절 근위부 골교정용 기능성 체외고정장치 개발 (Development of a Functional External Fixator System for Bone Deformity near Joints in Legs)

  • 이호중;전경진
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.162-169
    • /
    • 2005
  • The functional external fixator system fur bone deformity near joints in legs using the worm gear was developed for curing the difference angles in fracture bone and the lengthening bar for curing the difference length in fracture bone. Both experiments and FE analysis were performed to compare the elastic stiffness in several loading modes and to improve the functional external fixator system for the bone deformity. The FE model using the compressive and bending FE analysis was applied to the FE analysis due to the angle differences. The results show that the compressive stiffness value in experiment was 175.43N/mm; the bending stiffness value in experiment was 259.74N/mm; compressive stiffness value in FEM was 188.67N/mm; bending stiffness value in FEA was 285.71N/mm. The errors between experiments and FEA were less than 10%. The maximum stress (157MPa) to the angle of clamp was lower than the yield stress (176.4MPa) of SUS316L. The stiffnesses in both axial compressive and bending of the new fixator are about 2 times higher than other products except EBI (2003).

족관절 근위부 골교정용 기능성 체외고정장치 개발 (Development of a Functional External Fixator System for Bone Deformity near Joints in Legs)

  • 전경진;이호중
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1248-1251
    • /
    • 2004
  • The functional external fixator system for bone deformity near joints in legs using the worm gear was developed for curing the difference angles in fracture bone and the lengthening bar for curing the difference length in fracture bone. Both experiments and FE analysis were performed to compare the elastic stiffness in several loading modes and to improve the functional external fixator system for bone deformity near joints in legs. The FE model using the compressive and bending FE analysis was applied the FE analysis due to the angle differences. The results show that the compressive stiffness value in experiment was 175.43N/mm, the bending stiffness value in experiment was 259.74N/mm, compressive stiffness value in FEM was 188.67N/mm, bending stiffness value in FEA was 285.71N/mm. The errors between experiments and FEA were less than 10%. The maximum stress (157MPa) to the angle of clamp was lower than the yield stress (176.4MPa) of SUS316L. The stiffnesses in both axial compressive and bending of the new fixator are about 2 times higher than other products except EBI (2003).

  • PDF

외부프로그램 전압을 이용한 8비트 eFuse OTP IP 설계 (Design of an 8-Bit eFuse One-Time Programmable Memory IP Using an External Voltage)

  • 조규삼;김미영;강민철;장지혜;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제14권1호
    • /
    • pp.183-190
    • /
    • 2010
  • 본 논문에서는 외부 프로그램 전압으로 프로그램 가능한 로직 공정 기반의 eFuse OTP 셀을 제안하였다. 기존의 eFuse OTP 메모리 셀은 eFuse의 양극 (anode)에 연결된 SL (Source Line)으로 SL 구동회로의 전압강하를 거치면서 프로그램 데이터가 공급된 반면, 새롭게 제안된 eFuse 셀은 NMOS 프로그램 트랜지스터의 게이트에 프로그램 데이터가 공급되고 eFuse의 양극에 3.8V의 외부 프로그램 전압 (FSOURCE)이 전압강하 없이 공급된다. 그리고 제안된 셀의 FSOURCE 전압은 읽기 모드에서 0V 또는 플로팅 상태를 유지한다. 한편 본 논문에서는 FSOURCE 핀의 전압이 플로팅 상태인 경우는 회로적으로 0V로 바이어싱 하는 클램프 회로를 제안하였고, 로직 전압인 VDD (=1.8V)와 FSOURCE전압 사이에 스위칭 해주는 VPP 스위칭 회로를 제안하였다. 동부하이텍 $0.15{\mu}m$ generic 공정으로 설계된 8비트 eFuse OTP IP의 레이아웃 면적은 $359.92{\times}90.98{\mu}m^2$이다.

Development of a Functional Fixator System for Bone Deformity Near Joints

  • Chun, Keyoung-Jin;Lee, Ho-Jung
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.234-241
    • /
    • 2006
  • A functional external fixator system for bone deformity near the joints using worm gear was developed for curing the angle difference in fracture bones while the lengthening bar was developed for curing the differences in length, also in fracture bones. Both experiments and FE analysis were performed to compare the elastic stiffness in several loading modes and to improve the functional external fixator system for bone deformity near joints. The FE model using compressive and bending FE analysis was applied due to the angle differentiations. The results indicate that compressive stiffness value in the experiment was 175.43N/mm, bending stiffness value in the experiment was 259.74 N/mm, compressive stiffness value in the FEA was 188.67 N/mm, and bending stiffness value in the FEA was 285.71 N/mm. Errors between experiments and FEA were less than $10\%$ in both the 'compressive stiffness and the bending stiffness. The maximum stress (157 MPa) applied to the angle of the clamp was lower than the yield stress (176.4 MPa) of SUS316L. The degree of stiffness in both axial compression and bending of the new fixator are about 2 times greater than other products, with the exception of EBI (2003).

Strengthening of T-beams using external steel clamps and anchored steel plates

  • Yunus Dere;Yasin Onuralp Ozkilic;Ali Serdar Ecemis;Hasan Husnu Korkmaz
    • Steel and Composite Structures
    • /
    • 제48권4호
    • /
    • pp.405-417
    • /
    • 2023
  • In order to strengthen the reinforced concrete T-beams having insufficient shear strength, several strengthening techniques are available in the literature. In this study, three different strengthening strategies were numerically studied. First one is affixing steel plates to the beam surfaces. Second one includes tightening external steel bars vertically similar to beam stirrups. The last one is simultaneous application of these two strengthening procedures which is particularly proposed in this work. Available experimental test series in the literature were handled in the study. Finite element (FE) models of reinforced concrete beam specimens having sufficient (Beam-1) and low shear capacity (Beam-2) were created within ABAQUS environment. Strengthened beams with different techniques were also modelled to reflect improved shear capacity. FE simulations made it possible to investigate parameters that were not examined during the previous experimental studies. The results of the analyses were then compared and found consistent with the experimentally obtained data. Experimental and FEM analysis results are in agreement between 1% (closest) and 6%. (maximum). Beam-2 was stregthened with 5 new porposed methods. The rate of increase in shear strength varies between 33% and 64%. It was found that, the strengthening techniques were fairly useful in improving the shear capacity of the considered girder. The model with the proposed strengthening alternative has accomplished a higher load carrying capacity, ductility and stiffness than all of the other models.

1차측 클램핑 다이오드를 이용한 ZVS Three-Level DC/DC 컨버터에 관한 연구 (A Study on the Zero-Voltage-Switching Three-Level DC/DC Converter using Primary Clamping Diodes)

  • 김용
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.101-108
    • /
    • 2013
  • This paper presents A Zero-Voltage-Switching(ZVS) Three-Level DC/DC Converter using Primary Clamping Diodes. The Previous ZVS Three-Level DC/DC converter realizes ZVS for the switches with the use of the leakage inductance(or external resonant inductance) and the output capacitors of the switches, however the rectifier diodes suffer from recovery which results in oscillation and voltage spike. In order to solve this problem, this paper proposes a novel ZVS Three-Level DC/DC converter, which introduces two clamping diodes to the basic Three-Level converter to eliminate the oscillation and clamp the rectified voltage to the reflected input voltage.

1차측 클램핑 다이오드를 이용한 ZVS Three-Level DC/DC 컨버터에 관한 연구 (A Study on the Zero-Voltage-Switching Three-Level DC/DC Converter using Primary Clamping Diodes)

  • 전용진;김용;배진용;김필수;이은영;장부환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.164-168
    • /
    • 2004
  • A Zero-Voltage-Switching(ZVS) Three-Level Converter realizes ZVS for the switches with the use of the leakage inductance(or external resonant inductance) and the output capacitors of the switches, however; the rectifier diodes suffer from recovery which results in oscillation and voltage spike. In order to solve this problem, this paper proposes a novel ZVS Three-Level converter, which introduces two clamping diodes to the basic Three-Level converter to eliminate the oscillation and clamp the rectified voltage to the reflected input voltage.

  • PDF

GATING MECHANISM AND VOLTAGE-DEPENDENT BLOCK BY EXTERNAL DIVALENT CATIONS OF THE DELAYED RECTIFIER K CHANNEL IN RABBIT SINO-ATRIAL NODE CELLS

  • Ho, Won-Kyung;Lee, Suk-Ho;Earm, Yung-E
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 1996년도 정기총회 및 학술발표회
    • /
    • pp.5-5
    • /
    • 1996
  • In sino-atrial node cells which act as the normal pacemaker of the heart, K conductance in resting state is minimal due to the absence of inward rectifier K channels K conductance only increases when the membrane is depolarized by the activation of the delayed rectifier K current I$\_$k/. In the present study, we investigated the gating mechanism of$\_$k/ using the whole cell patch clamp technique in isolated single sinoatrial cells of the rabbit. (omitted)

  • PDF