• Title/Summary/Keyword: external IR sources

Search Result 14, Processing Time 0.025 seconds

A Study on an Infrared Illumination Stabilization Method in a Head Mounted Eye Tracking System for Sport Applications (착용형 시선 추적 장치의 스포츠 분야 적용을 위한 적외선 조명 변화 최소화에 관한 연구)

  • Lee, Sang-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.265-272
    • /
    • 2009
  • In this paper, a simple optical method that uses an infrared(IR) cut filter is proposed to minimize variation of eye image by external infrared(IR) sources in a video based head mounted eye tracking system that is used in the field of sports. For this, the IR cut filter is attached to a head mount of the eye tracking system, and the camera with an IR LED is located between the IR cut filter and eye. In this structure, external IR is blocked by the IR cut filter, and the IR intensity on the eye can be controlled by the IR LED. Therefore, the illumination condition of the camera to capture the eye can be stable without being affected by external IR illuminations. To verify the proposed idea, variation of the eye image and intensity of the IR with/without the IR cut filter is measured under various illumination conditions. The measured data show that the IR cut filter method can block external IR effectively, and complex pupil detection algorithms can be replaced by a simple binarized method.

The Clinical Application of Radioactive Iridium (Ir-192) Brachytherapy (방사선 이리디움(Ir-192) 근접치료의 임상적 응용)

  • Yoo, Seong-Yul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.3 no.1
    • /
    • pp.11-18
    • /
    • 1989
  • Brachytherapy is known to be a good modality to achieve local control as a boost treatment following limited external irradiation, which may reduce the external beam related complication particularly in head and neck cancer. The authors developed iridium-192 ribbons recently to replace the radium needles in the field of brachytherapy. Total of 48 cases of head and neck and pelvic-perineal cancer patients had been treated with Ir-192 ribbons during last two years from October 1986 to September 1988, and the results were analyzed to assess the applicability of the fabricated sources. The conclusion is as follows; 1. Iridium implant resulted excellent tumor control effect in clinical application. 2. Iridium is superior than radium and cecium in brachytherapy because of easier to use and lesser exposure to the personnel. 3. Afterloading technique is useful to modify dose distribution, to expand treatment site and method, and to develop interstitial hyperthermia.

  • PDF

QUALITY OF KOREAN GINSENG DRIED WITH A PROTOTYPE CONTINUOUS FLOW DRYER USING FAR INFRARED RAY AND HEATED-AIR

  • Park, S. J.;Kim, S. M.;Kim, M. H.;Kim, C. S.;Lee, C. H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.388-395
    • /
    • 2000
  • This study was performed to examine the effects of infrared (IR)/heated-air combination drying on some quality attributes of Korean white ginsengs. Ginseng roots were dried in a dryer where both the far infrared ray and heated-air are available as drying energy sources. Diametral shrinkage, external color, total saponin content, and ginsenosides and free sugar composition of the IR/heated-air combination dried ginsengs were measured and compared with those of commercial white ginseng products. The external color became lower in lightness and higher in saturation as the IR radiating plate temperature increased. IR/heated-air combination dried white ginsengs at IR plate temperature of 100$^{\circ}C$ was comparable to the commercial white ginseng products in color characteristics. Diametral shrinkage ratios ranged from 20 to 36% and appeared to be independent on the different drying methods. No definite evidence could be found whether the IR/heated-air combination drying and the conventional. hot-air drying practice resulted in white ginsengs having different ginsenoside contents and compositions. No conclusion could be made on whether the various drying treatments used in the study had effects on the free sugar contents and compositions of white ginsengs.

  • PDF

Derivation of External Exposure Characteristics of Industrial Radiography Based on Empirical Evidence

  • Cho, Junik;Kim, Euidam;Kwon, Tae-Eun;Chung, Yoonsun
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.93-98
    • /
    • 2022
  • Background: This study aims to derive the characteristics of each work type for industrial radiography based on empirical evidence through expert advice and a survey of radiation workers of various types of industrial radiography. Materials and Methods: According to a Korean report, work types of industrial radiography are classified into indoor tests, underground pipe tests, tests in a shielded room (radiographic testing [RT] room test), outdoor field tests, and outdoor large structure tests. For each work type, exposure geometry and radiation sources were mainly identified through the expert advice and workers' survey as reliable empirical evidence. Results and Discussion: The expert advice and survey results were consistent as the proportion of the work types were high in the order of RT room test, outdoor large structure test, underground pipe test, outdoor field test, and indoor test. The outdoor large structure test is the highest exposure risk work type in the industrial radiography. In most types of industrial radiography, radiation workers generally used 192Ir as the main source. In the results of the survey, the portion of sources was high in the order of 192Ir, X-ray generator, 60Co, and 75Se. As the exposure geometry, the antero-posterior geometry is dominant, and the rotational and isotropic geometry should be also considered with the work type. Conclusion: In this study, through expert advice and a survey, the external exposure characteristics for each work type of industrial radiography workers were derived. This information will be used in the reconstruction of organ dose for health effects assessment of Korean radiation workers.

Development and Application of Test Apparatus for Classification of Sealed Source (밀봉선원의 성능시험을 위한 장치 개발 및 적용)

  • Kim, Dong-Hak;Seo, Ki-Seog;Bang, Kyoung-Sik;Lee, Ju-Chan;Son, Kwang-Je
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.35-44
    • /
    • 2007
  • Sealed sources have to conducted the tests be done according to the classification requirements for their typical usages in accordance with the relevant domestic notice standard and ISO 2919. After each test, the source shall be examined visually for loss of integrity and pass an appropriate leakage test. Tests to class a sealed source are temperature, external pressure, impact, vibration and puncture test. The environmental test conditions for tests with class numbers are arranged in increasing order of severity. In this study, the apparatus of tests, except the vibration test, were developed and applied to three kinds of sealed source. The conditions of the tests to class a sealed source were stated and the difference between the domestic notice standard and ISO 2919 were considered. And apparatus of the tests were made. Using developed apparatus we conducted the tests for $^{192}Ir$ brachytherapy sealed source and two kinds of sealed source for industrial radiography. $^{192}Ir$ brachytherapy sealed source is classified by temperature class 5, external pressure class 3, impact class 2 and vibration and puncture class 1. Two kinds of sealed source for industrial radiography are classified by temperature class 4, external pressure class 2, impact and puncture class 5 and vibration class 1. After the tests, Liquid nitrogen bubble test and vacuum bubble test were done to evaluate the safety of the sealed sources.

Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS. (RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰)

  • Moon, Un-Chull
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

Crossbreeding and parental lineage influences the diversity and community structure of rice seed endophytes

  • Walitang, Denver I.;Halim, MD Abdul;Kang, Yeongyeong;Kim, Yongheon;Sa, Tongmin
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.161-161
    • /
    • 2017
  • Seed endophytes are very remarkable groups of bacteria for their unique abilities of being vertically transmitted and conserved. As plants attain hybrid vigor and heterosis in the process of crossbreeding, this might also lead to the changes in the community structure and diversity of plant endophytes in the hybrid plants ultimately affecting the endophytes of the seeds. It would be interesting to characterize how seed endophyte composition change over time. The objective of this study is to gain insights into the influence of natural crossbreeding and parental lineage in the seed bacterial endophytic communities of two pure inbred lines exploring contributions of the two most important sources of plant endophytes - colonization from external sources and vertical transmission via seeds. Total genomic DNA was isolated from rice seeds and bacterial DNA was selectively amplified by PCR. The diversity of endophytic bacteria was studied through Terminal-Restriction Fragment Length Polymorphism (T-RFLP) analysis. Diversity between the original parents and the pure inbred line may show significant differences in terms of richness, evenness and diversity indices. Heat maps reveal astonishing contributions of both or either parents (IR29 ${\times}$ Pokkali and AT401 ${\times}$ IR31868) in the shaping of the bacterial seed endophytes of the hybrid, FL478 and IC32, respectively. Most of the T-RFs of the subsequent pure inbred line could be traced to any or both of the parents. Comparison of common and genotype-specific T-RFs of parents and their offspring reveals that majority of the T-RFs are shared suggesting higher transmission of bacterial communities common to both parents. The parents influence the bacterial community of their offspring. Unique T-RFs of the offspring also suggest external sources of colonization particularly as the seeds are cultivated in different ecogeographical locations. This study showed that host parental lines contributed greatly in the shaping of bacterial seed endophytes of their offspring. It also revealed transmission and potential conservation of core seed bacterial endophytes that generally become the dominant microbiota in the succeeding generations of plant hosts.

  • PDF

Evaluation Absorbed Dose During the Breast Cancer Brachytherapy in Canine Phantom (반려견 팬텀에서 유방암 근접방사선치료 시 흡수선량 평가)

  • Kim, Jung-Hoon;Lee, Deuk-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.523-528
    • /
    • 2020
  • The application of breast cancer, which has the highest incidence in females among cancer that is the number one cause of death for dogs, was to be evaluated the absorbed dose during brachytherapy using simulation. MCNPX program was used for simulation, and a small size canine phantom was produced to measure absorbed dose. The results of the absorbed dose was the highest at 192Ir to 1.02E-12 Gy/# for tumors, and the same tendency was shown for internal and external absorbed dose. Therefore, the selection of appropriate sources for dog breast cancer should be considered in brachytherapy, taking into account dog breeds and exposures.

THERMAL MODELS AND FAR INFRARED EMISSION OF ASTEROIDS

  • KIM SAM;LEE HYUNG MOK;NAKAGAWA TAKAO;HASEGAWA SUNAO
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.21-31
    • /
    • 2003
  • ASTRO-F /FIS will carry out all sky survey in the wavelength from 50 to 200 ${\mu}m$. At far infrared, stars and galaxies may not be good calibration sources because the IR fluxes could be sensitive to the dust shell of stars and star formation activities of galaxies. On the other hand, asteroids could be good calibration sources at far infrared because of rather simple spectral energy distribution. Recent progresses in thermal models for asteroids enable us to calculate the far infrared flux fairly accurately. We have derived the Bond albedos and diameters for 559 asteroids based on the IRAS and ground based optical data. Using these thermal parameters and standard thermal model, we have calculated the spectral energy distributions of asteroids from 10 to 200 ${\mu}m$. We have found that more than $70\%$ of our sample asteroids have flux errors less than $10\%$ within the context of the best fitting thermal models. In order to assess flux uncertainties due to model parameters, we have computed SEDs by varing external parameters such as emissivity, beaming parameter and phase integral. We have found that about 100 asteroids can be modeled to be better than $5.8\%$ of flux uncertainties. The systematic effects due to uncertainties in phase integral are not so important.

The Effect of Iridium-192 Implant in the Treatment of Head and Neck Cancer (두경부암에서 방사성이리디움 삽입치료의 효과)

  • Yoo Seong-Yul;Koh Kyoung-Hwan;Cho Chul-Koo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.4 no.1
    • /
    • pp.13-19
    • /
    • 1988
  • Brachytherapy is known to be a good modality to achieve local control as a boost treatment following limited external irradiation, which may reduce the external beam related acute radiation sickness, particularly in head and neck cancer. The authors developed iridium-192 ribbons recently to replace the radium needles. Total of 13 head and neck cancer patients had been treated with Ir-192 ribbons during last one year from October 1986 to September 1987, and the results were analysed to assess the applicability of the fabricated sources. The conclusion is as follows; 1) Iridium implant achieved 54% (7/13) of complete response and 69% (9/13) of overall response rate in head and neck cancer. 2) Iridium is superior to radium and cecium in brachytherapy because of easier to use and lesser exposure to the personnel. 3) Afterloading technique is useful to modify dose distribution, to expand treatment site and method, and to develop interstitial hyperthermia.

  • PDF