• 제목/요약/키워드: external IR sources

검색결과 14건 처리시간 0.029초

착용형 시선 추적 장치의 스포츠 분야 적용을 위한 적외선 조명 변화 최소화에 관한 연구 (A Study on an Infrared Illumination Stabilization Method in a Head Mounted Eye Tracking System for Sport Applications)

  • 이상철
    • 제어로봇시스템학회논문지
    • /
    • 제15권3호
    • /
    • pp.265-272
    • /
    • 2009
  • In this paper, a simple optical method that uses an infrared(IR) cut filter is proposed to minimize variation of eye image by external infrared(IR) sources in a video based head mounted eye tracking system that is used in the field of sports. For this, the IR cut filter is attached to a head mount of the eye tracking system, and the camera with an IR LED is located between the IR cut filter and eye. In this structure, external IR is blocked by the IR cut filter, and the IR intensity on the eye can be controlled by the IR LED. Therefore, the illumination condition of the camera to capture the eye can be stable without being affected by external IR illuminations. To verify the proposed idea, variation of the eye image and intensity of the IR with/without the IR cut filter is measured under various illumination conditions. The measured data show that the IR cut filter method can block external IR effectively, and complex pupil detection algorithms can be replaced by a simple binarized method.

방사선 이리디움(Ir-192) 근접치료의 임상적 응용 (The Clinical Application of Radioactive Iridium (Ir-192) Brachytherapy)

  • 유성열
    • 대한방사선치료학회지
    • /
    • 제3권1호
    • /
    • pp.11-18
    • /
    • 1989
  • Brachytherapy is known to be a good modality to achieve local control as a boost treatment following limited external irradiation, which may reduce the external beam related complication particularly in head and neck cancer. The authors developed iridium-192 ribbons recently to replace the radium needles in the field of brachytherapy. Total of 48 cases of head and neck and pelvic-perineal cancer patients had been treated with Ir-192 ribbons during last two years from October 1986 to September 1988, and the results were analyzed to assess the applicability of the fabricated sources. The conclusion is as follows; 1. Iridium implant resulted excellent tumor control effect in clinical application. 2. Iridium is superior than radium and cecium in brachytherapy because of easier to use and lesser exposure to the personnel. 3. Afterloading technique is useful to modify dose distribution, to expand treatment site and method, and to develop interstitial hyperthermia.

  • PDF

QUALITY OF KOREAN GINSENG DRIED WITH A PROTOTYPE CONTINUOUS FLOW DRYER USING FAR INFRARED RAY AND HEATED-AIR

  • Park, S. J.;Kim, S. M.;Kim, M. H.;Kim, C. S.;Lee, C. H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.388-395
    • /
    • 2000
  • This study was performed to examine the effects of infrared (IR)/heated-air combination drying on some quality attributes of Korean white ginsengs. Ginseng roots were dried in a dryer where both the far infrared ray and heated-air are available as drying energy sources. Diametral shrinkage, external color, total saponin content, and ginsenosides and free sugar composition of the IR/heated-air combination dried ginsengs were measured and compared with those of commercial white ginseng products. The external color became lower in lightness and higher in saturation as the IR radiating plate temperature increased. IR/heated-air combination dried white ginsengs at IR plate temperature of 100$^{\circ}C$ was comparable to the commercial white ginseng products in color characteristics. Diametral shrinkage ratios ranged from 20 to 36% and appeared to be independent on the different drying methods. No definite evidence could be found whether the IR/heated-air combination drying and the conventional. hot-air drying practice resulted in white ginsengs having different ginsenoside contents and compositions. No conclusion could be made on whether the various drying treatments used in the study had effects on the free sugar contents and compositions of white ginsengs.

  • PDF

Derivation of External Exposure Characteristics of Industrial Radiography Based on Empirical Evidence

  • Cho, Junik;Kim, Euidam;Kwon, Tae-Eun;Chung, Yoonsun
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.93-98
    • /
    • 2022
  • Background: This study aims to derive the characteristics of each work type for industrial radiography based on empirical evidence through expert advice and a survey of radiation workers of various types of industrial radiography. Materials and Methods: According to a Korean report, work types of industrial radiography are classified into indoor tests, underground pipe tests, tests in a shielded room (radiographic testing [RT] room test), outdoor field tests, and outdoor large structure tests. For each work type, exposure geometry and radiation sources were mainly identified through the expert advice and workers' survey as reliable empirical evidence. Results and Discussion: The expert advice and survey results were consistent as the proportion of the work types were high in the order of RT room test, outdoor large structure test, underground pipe test, outdoor field test, and indoor test. The outdoor large structure test is the highest exposure risk work type in the industrial radiography. In most types of industrial radiography, radiation workers generally used 192Ir as the main source. In the results of the survey, the portion of sources was high in the order of 192Ir, X-ray generator, 60Co, and 75Se. As the exposure geometry, the antero-posterior geometry is dominant, and the rotational and isotropic geometry should be also considered with the work type. Conclusion: In this study, through expert advice and a survey, the external exposure characteristics for each work type of industrial radiography workers were derived. This information will be used in the reconstruction of organ dose for health effects assessment of Korean radiation workers.

밀봉선원의 성능시험을 위한 장치 개발 및 적용 (Development and Application of Test Apparatus for Classification of Sealed Source)

  • 김동학;서기석;방경식;이주찬;손광재
    • Journal of Radiation Protection and Research
    • /
    • 제32권1호
    • /
    • pp.35-44
    • /
    • 2007
  • 밀봉선원은 과학기술부고시에 의거하여 사용용도별로 등급에 따라 해당 성능시험을 수행하고, 각 성능시험을 거친 후 해당 방사성핵종의 방사능 누설량이 200베크렐을 초과하지 아니하여야 한다. 이러한 성능시험은 온도시험, 의부압력시험, 충격시험, 진동시험 및 관통시험으로 구성되어 있으며 등급에 따라서 각 성능시험의 조건이 각각 다르다. 본 연구에서는 진동시험을 제외한 성능시험을 위한 장치를 개발하고 이를 세 가지 종류의 밀봉선원의 성능시험에 적용하였다. 의료용 근접치료기에 사용되는 근접치료기용 선원은 5등급의 온도시험, 3등급의 외압시험, 2등급의 충격시험을 수행하여 'C53211' 등급의 기준에 적합함을 보였다. 산업용 조사기에 사용되는 $^{75}Se$$^{169}Yb$ 선원에 대하여 4등급의 온도시험, 3등급의 외압시험, 5등급의 충격시험과 관통시험을 실시하여 'C43515' 등급의 기준에 적합함을 입증하였다.

RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰 (Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS.)

  • 문언철
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

Crossbreeding and parental lineage influences the diversity and community structure of rice seed endophytes

  • Walitang, Denver I.;Halim, MD Abdul;Kang, Yeongyeong;Kim, Yongheon;Sa, Tongmin
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.161-161
    • /
    • 2017
  • Seed endophytes are very remarkable groups of bacteria for their unique abilities of being vertically transmitted and conserved. As plants attain hybrid vigor and heterosis in the process of crossbreeding, this might also lead to the changes in the community structure and diversity of plant endophytes in the hybrid plants ultimately affecting the endophytes of the seeds. It would be interesting to characterize how seed endophyte composition change over time. The objective of this study is to gain insights into the influence of natural crossbreeding and parental lineage in the seed bacterial endophytic communities of two pure inbred lines exploring contributions of the two most important sources of plant endophytes - colonization from external sources and vertical transmission via seeds. Total genomic DNA was isolated from rice seeds and bacterial DNA was selectively amplified by PCR. The diversity of endophytic bacteria was studied through Terminal-Restriction Fragment Length Polymorphism (T-RFLP) analysis. Diversity between the original parents and the pure inbred line may show significant differences in terms of richness, evenness and diversity indices. Heat maps reveal astonishing contributions of both or either parents (IR29 ${\times}$ Pokkali and AT401 ${\times}$ IR31868) in the shaping of the bacterial seed endophytes of the hybrid, FL478 and IC32, respectively. Most of the T-RFs of the subsequent pure inbred line could be traced to any or both of the parents. Comparison of common and genotype-specific T-RFs of parents and their offspring reveals that majority of the T-RFs are shared suggesting higher transmission of bacterial communities common to both parents. The parents influence the bacterial community of their offspring. Unique T-RFs of the offspring also suggest external sources of colonization particularly as the seeds are cultivated in different ecogeographical locations. This study showed that host parental lines contributed greatly in the shaping of bacterial seed endophytes of their offspring. It also revealed transmission and potential conservation of core seed bacterial endophytes that generally become the dominant microbiota in the succeeding generations of plant hosts.

  • PDF

반려견 팬텀에서 유방암 근접방사선치료 시 흡수선량 평가 (Evaluation Absorbed Dose During the Breast Cancer Brachytherapy in Canine Phantom)

  • 김정훈;이득희
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.523-528
    • /
    • 2020
  • 반려견의 사망원인 1위인 암 중 암컷에게서 가장 높은 발생률을 보이는 유방암을 대상으로 근접방사선치료 수행 시 모의모사를 이용한 흡수선량 측정을 바탕으로 적용성을 평가하고자 하였다. 모의모사를 위해 MCNPX 프로그램을 이용하였으며, 흡수선량 측정을 위해 소형견 크기의 수학적 팬텀을 제작 하였다. 흡수선량 측정결과 종양의 경우 192Ir에서 1.02E-12 Gy/#으로 흡수선량이 가장 높은 것으로 나타났으며, 내·외부 흡수선량에서도 동일한 경향성으로 나타났다. 따라서 반려견 유방암의 근접방사선치료 시 견종과 피폭을 고려한 적절한 선원의 선택이 고려되어야 될 것이다.

THERMAL MODELS AND FAR INFRARED EMISSION OF ASTEROIDS

  • KIM SAM;LEE HYUNG MOK;NAKAGAWA TAKAO;HASEGAWA SUNAO
    • 천문학회지
    • /
    • 제36권1호
    • /
    • pp.21-31
    • /
    • 2003
  • ASTRO-F /FIS will carry out all sky survey in the wavelength from 50 to 200 ${\mu}m$. At far infrared, stars and galaxies may not be good calibration sources because the IR fluxes could be sensitive to the dust shell of stars and star formation activities of galaxies. On the other hand, asteroids could be good calibration sources at far infrared because of rather simple spectral energy distribution. Recent progresses in thermal models for asteroids enable us to calculate the far infrared flux fairly accurately. We have derived the Bond albedos and diameters for 559 asteroids based on the IRAS and ground based optical data. Using these thermal parameters and standard thermal model, we have calculated the spectral energy distributions of asteroids from 10 to 200 ${\mu}m$. We have found that more than $70\%$ of our sample asteroids have flux errors less than $10\%$ within the context of the best fitting thermal models. In order to assess flux uncertainties due to model parameters, we have computed SEDs by varing external parameters such as emissivity, beaming parameter and phase integral. We have found that about 100 asteroids can be modeled to be better than $5.8\%$ of flux uncertainties. The systematic effects due to uncertainties in phase integral are not so important.

두경부암에서 방사성이리디움 삽입치료의 효과 (The Effect of Iridium-192 Implant in the Treatment of Head and Neck Cancer)

  • 류성렬;고경환;조철구
    • 대한두경부종양학회지
    • /
    • 제4권1호
    • /
    • pp.13-19
    • /
    • 1988
  • Brachytherapy is known to be a good modality to achieve local control as a boost treatment following limited external irradiation, which may reduce the external beam related acute radiation sickness, particularly in head and neck cancer. The authors developed iridium-192 ribbons recently to replace the radium needles. Total of 13 head and neck cancer patients had been treated with Ir-192 ribbons during last one year from October 1986 to September 1987, and the results were analysed to assess the applicability of the fabricated sources. The conclusion is as follows; 1) Iridium implant achieved 54% (7/13) of complete response and 69% (9/13) of overall response rate in head and neck cancer. 2) Iridium is superior to radium and cecium in brachytherapy because of easier to use and lesser exposure to the personnel. 3) Afterloading technique is useful to modify dose distribution, to expand treatment site and method, and to develop interstitial hyperthermia.

  • PDF