• 제목/요약/키워드: exposure waterproofing

검색결과 32건 처리시간 0.025초

돌기 시스템을 이용한 입체보강형시트의 옥상노출복합방수공법 적용에 관한 재료 및 공법적 연구 (Study on the Application of Site for Exposure Type of Complex Waterproofing Method with Liquefied Waterproof using of Vertical Type Reinforcing Sheet Material Reinforced Sheet Rising System in the Roof Tops)

  • 오상근;손문세;김진성;여인수
    • 한국건축시공학회지
    • /
    • 제6권4호
    • /
    • pp.69-75
    • /
    • 2006
  • It often happen water leakage that roof membrane have a poor condition such as direct exposed to rain, ultraviolet lays, temperature change compare with other part of waterproofing. There are difficult to maintain the quality of waterproofing and durability due to use only few waterproofing materials in practical in spite of development and use the various waterproofing material as solution of these poor condition. Therefore, in this thesis, I would like to know the property to apply field and suggest other method to develop for this waterproofing method to adopt various field condition for roof tops, as searching exposed and complex waterproofing technology for roof tops which is reinforced sheet using rising system have a regular pitch, depth, space.

무기질계 탄성 도막재와 자착식 고무 아스팔트 시트를 결합한 지붕구조물 비노출 방수공법에 관한 실험적 연구 (An Experimental Study about appling non-Exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Self adhesive Rubberized Asphalt sheet to the Roof Structure.)

  • 문유석;이선규;송제영;곽규성;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.613-616
    • /
    • 2008
  • 이 연구는 기존 무기질계 탄성 도막 방수재와 고무 아스팔트 시트 방수공법을 지붕구조물 적용에 있어서 나타나는 문제점들을 보완하기 위하여 두 재료를 결합한 비노출 방수공법 재료에 대한 연구이다. 이에 따라 두 재료를 결합한 방수공법의 7가지 성능평가를 실시하여 지붕구조물의 적용 특성을 확인하였다. 종합적인 연구 결과 본 복합방수공법은 지붕구조물에서 요구하는 중요한 성능인 표준 및 저온 고온 하에서의 기본적인 인장성능을 능가하고 구조물 거동에 따른 안정성 확보와 구조체와의 부착성능을 확보 함으로써 비노출 복합방수공법으로써 콘크리트 구조물에 적응가능하다고 판단된다.

  • PDF

방수재료 및 공법의 내구성 평가를 위한 복합열화분석용 3차원 거동대응 시험결과 (A Study on the Analysis of 3 Dimensional Substrate Behaviour of Complex Environmental Deterioration and the Analysis of Results)

  • 송제영;서현재;최은규;이정훈;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.189-190
    • /
    • 2018
  • KS standards mostly relate to single component material evaluation, so in cases of underground structure environments, most cannot predict the existing composite forms of deterioration, resulting in the applied waterproofing materials becoming unable to respond to these damaging factors. Current domestic waterproofing market in Korea mainly uses single-ply waterproofing materials comprised of coatings or waterproof sheets and two or more-ply composite waterproofing methods. In order to evaluate these types of composite waterproofing systems, a new test equipment and method that incorporates various deterioration conditions (joint displacement, chemical exposure, water pressure etc) was developed. In a comparison testing, the results showed that flexible type materials have higher response performance towards joint displacement than the hardened material.

  • PDF

망사형 PE직물과 고점도 우레탄을 이용한 복층형 노출 방수공법에 관한연구 (A Experimental Study on the Complex Waterproofing Method of Exposure using PE Textiles of Mesh type and Highly Viscous Urethane)

  • 소욱동;송제영;김영석;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.127-130
    • /
    • 2011
  • The duplex waterproofing construction method has been investigated to improve various problems (how to fix the sheet, breaking, air/water pocket, and cracks caused by different materials) of the existing rooftop exposed waterproofing construction method. By using fiber sheet, Net PE fabric, and thixotropy urethane with high viscosity, the waterproofing construction method is to glue the ground and waterproof course by circular dot. The method is also to construct the waterproof course with high hardness by using waterproof membrane coatings in upper hybrid system. By gluing the ground and the waterproof course by circular dot, the study is expected to be useful to minimize the simultaneous breaking in the waterproof course as tensile stress is buffer in case of the ground crackling. Also, since the waterproofing construction method is good at moving and emitting vapor from the ground, it is considered to be effective to minimize any damages caused by air/water pocket and get loose of the waterproof course.

  • PDF

돌기형 접합 보강재를 이용한 옥상 노출 복합방수의 조인트 시공방법에 관한 연구 (Sheet Jointing Method of the Roof Exposed Hybrid Waterproofing Using the Bump-type Joint Reinforcement)

  • 김명지;안기원;김동춘;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.147-148
    • /
    • 2018
  • Seat waterproofing materials applied to the roof of a building concrete structure inevitably produce joints and are applied with opposite dam joints or overlapping joints depending on the waterproof material applied to the top of the sheet. In this case, the joint performance is determined by the material at the top, rather than by the superimposed joint. In order to solve this problem, various reinforcements have been used to apply to the connecting parts of the opposite dam, but the problem of attachment between different materials or the lack of reinforcement of the joint tape has not been solved. Therefore, for the purpose of securing tensile performance to the joints, this study is used as a reinforcement for the joints of PP materials with high tensile performance and as a reinforcement for nylon materials.

  • PDF

엠보싱 PVC 시트를 이용한 부분절연(部分絶緣) 블록형 옥상(屋上) 비노출 복합방수(複合防水)공법 개발(開發)에 관(關)한 연구(硏究) (Research about point adhesion disconnection type non-exposure composition waterproof method of construction development that use embossing PVC sheet)

  • 위태환;강효진;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.37-40
    • /
    • 2003
  • This present paper mainly contains adhesion part disconnection type exposure composition waterproof method using embossing PVC sheet. The existing polymer resin coating and sheet waterproofing construction method have, however, some weak point such as being decrease life cycle of concrete with water leaking from materials be affected by crack and movement dash bond concrete through the whole-adhere construction. Above the reason, this paper has particular method increasing crack-defending performance from stress occurred concrete movement by part disconnection, adds maintain waterproofing performance subordinate sheet, that can be contributed a convenience of maintenance which is decreasing industrial waste and repair construction cycle through the part repair in case of leaking water.

  • PDF

엠보싱 PVC 시트를 이용한 부분절연 블록형 옥상 비노출 복합방수공법 개발에 관한 연구 (Research about point adhesion disconnection type non-exposure composition waterproof method of construction development that use embossing PVC sheet)

  • 위태환;강효진;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.37-40
    • /
    • 2003
  • This present paper mainly contains adhesion part disconnection type exposure composition waterproof method using embossing PVC sheet. The existing polymer resin coating and sheet waterproofing construction method have, however, some weak point such as being decrease life cycle of concrete with water leaking from materials be affected by crack and movement dash bond concrete through the whole-adhere construction. Above the reason, this paper has particular method increasing crack-defending performance from stress occurred concrete movement by part disconnection, adds maintain waterproofing performance subordinate sheet, that can be contributed a convenience of maintenance which is decreasing industrial waste and repair construction cycle through the part repair in case of leaking water.

  • PDF

면섬유가 보강된 폴리우레탄계 복합시트의 기초 물성 평가 (Evaluation on the Basic Properties of Polyurethane Composite Sheet Reinforced with Non-Woven Fabric)

  • 김지현;도승배;박정원;남기융;정철우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.238-239
    • /
    • 2017
  • Waterproofing is a very important process in terms of durability of buildings. The materials used for waterproofing work to protect the concrete structure from external deterioration factors. In particular, the waterproofing materials applied to the exterior of the concrete structure have various problems due to changes in the external environment and variables in the construction process. The waterproof layer is repeatedly dried and shrunk according to changes in the external moisture environment, and the surface may be deteriorated due to exposure to long-term sunlight. In the case of the roof waterproofing in the structure, the waterproof layer which does not have a sufficient curing period shows much swelling and floating phenomenon. These defects, such as swelling and lifting, account for most of the defects that occur in the waterproof layer of the concrete slabs. Generally, it is difficult to expect the same level of performance as the initial state even if the waterproofing work is repaired when a defect occurs. Therefore, it is possible to reduce the defects of the waterproof layer such as swelling and lifting by forming a waterproof layer which can be integrated with the concrete surface by using a polyurethane type waterproofing material having a relatively low defective ratio compared to other waterproofing materials. So in this study, the basic properties of polyurethane waterproof sheet reinforced with non-woven fabric are investigated in order to understand field applicability.

  • PDF

점착형 도막.시트 일체형 방수재를 이용한 비노출용 복합 방수공법에 관한 실험적 연구 (An Experimental Study on the Non-Exposure Composite Waterproofing Method used Adhesion Liquid and Sheet Integrate Waterproofing Material)

  • 김진성;선윤숙;박진상;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.125-128
    • /
    • 2007
  • The problem of water leakage due to damaging waterproof in concrete structure, causes the impediment in a long term and shortened the life span of durability. There are a lot of techniques for repair and reinforcement to improve using environment. However, the improper construction which is unconsidered various environmental conditions, could effect to increase the maintenance expenses. Therefore, this study will be compared and estimated the adhesion liquid and sheet integrate waterproofing material, as analyzing the existing problem. For those result, we would like to arrange the alterative plan for the long durability and user needs of concrete structure.

  • PDF

건설현장 우레탄 방수작업자의 휘발성 유기화합물 및 톨루엔 디이소시아네이트 노출평가 (Exposure Assessment of Solvents and Toluene Diisocyanates among Polyurethane Waterproofing Workers in the Construction industry)

  • 박현희;황은송;노지원;장광명;박승현;윤충식
    • 한국산업보건학회지
    • /
    • 제30권2호
    • /
    • pp.134-152
    • /
    • 2020
  • Objectives: The objective of this study was to evaluate volatile organic compounds (VOCs) and toluene diisocyanates (TDIs) exposure among polyurethane waterproofing workers in the construction industry. Methods: Task-based personal air samplings were carried out at seven construction sites using organic vapor monitor for VOCs (n=88) and glass fiber filters coated with 1-(2-pyridyl)piperazine(1-2PP) for TDIs (n=81). The concentration of VOCs and TDIs were shown for four different work types(mixing paint, primer roller painting, urethane resin spread painting, painter assistant) at five different worksites (rooftop, ground parking lot, piloti, bathroom, and swimming pool). The two TDI sampling methods (filter vs impinger) were evaluated in parallel to compare the concentrations. Results: The geometric mean(GM) concentration of VOCs Exposure Index (EI) was highest for primer roller painting (1.4), followed in order by, urethane resin spread painting (0.85), mixing paint (0.53), and painter assistant (0.35) by work types. The GM of VOCs EI was highest for bathroom (1.4) followed in order by, swimming pool (0.85), piloti (0.89), ground parking lot (0.82) and rooftop (0.57) by worksites. The GM of 2,4-/2,6-TDI concentration was 0.052 ppb and 0.432 ppb each. There was no statistical difference in TDIs concentrations among worksites. The concentration of 2,6-TDI was ten times higher than that of 2,4-TDI. The concentration of 2,6-TDI by impinger method was 5.7 times higher than that by filter method. Conclusions: In this study, we found 38.6% of the VOCs samples exceeded the occupational exposure limits and 19.8% of the 2,6-TDI samples exceeded 1 ppb among polyurethane waterproofing workers. The most important determinants that increase the concentration of VOCs and TDIs was indoor environment and primer painting work.