• 제목/요약/키워드: exposure time and temperature

검색결과 495건 처리시간 0.032초

Selective Catalytic Reduction (SCR) 환경에서 18% 크롬 스테인리스강의 부식 거동 (Corrosion behaviors of 18Cr Stainless Steels in Selective Catalytic Reduction Environments)

  • 김희산
    • Corrosion Science and Technology
    • /
    • 제22권3호
    • /
    • pp.175-186
    • /
    • 2023
  • Effects of high-temperature environment and low-temperature environment on corrosion behaviours of 18Cr stainless steels (type 304L, type 441) in simulated selective catalytic reduction (SCR) environments were studied using weight loss test in each environment and rust analysis. With time to exposure to the high-temperature environment, type 441 was more resistant to corrosion than type 304L due to both higher diffusivity of Cr and lower thermal expansion coefficient in α-iron. The former provides a stable protective Cr2O3 layer. The latter leaded to low residual stress between scale and steel, reducing the spallation of the scale. With time to exposure to the low-temperature environment, on the other hand, type 304L was more resistant to corrosion than type 441. The lower resistance of type 441 was caused by Cr-depleted zone with less than 11% formed during the pre-exposure to a high-temperature environment, unlike type 304L. It was confirmed by results from the crevice corrosion test of sensitised 11Cr steel. Hence, to achieve higher corrosion resistance in simulated SCR environments, ferritic stainless steels having lower thermal expansion coefficient and higher diffusivity of Cr but containing more than 18% Cr are recommended.

홀로그래픽 간섭계와 PIV를 이용한 Hele-Shaw Convection Cell 내부 열유동 해석 (Measurement of Thermal Flow in a Hele-Shaw Convection Cell Using Holographic Interferometry and PIV Technique)

  • 김석;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.35-38
    • /
    • 2002
  • Variations of temperature and velocity fields in a Hele-Shaw Convection Cell (HSC) were measured using a holographic interferometry and PIV technique with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. PIV results show that flow inside the HSC is periodic and the oscillating state is well matched with the temperature field results. The holographic interferometry and PIV techniques employed in this study are useful for analyzing the unsteady convective thermal fluid flows.

  • PDF

Effect of Gaseous Ozone Exposure on the Bacteria Counts and Oxidative Properties of Ground Hanwoo Beef at Refrigeration Temperature

  • Cho, Youngjae;Muhlisin, Muhlisin;Choi, Ji Hye;Hahn, Tae-Wook;Lee, Sung Ki
    • 한국축산식품학회지
    • /
    • 제34권4호
    • /
    • pp.525-532
    • /
    • 2014
  • This study was designed to elucidate the effect of ozone exposure on the bacteria counts and oxidative properties of ground Hanwoo beef contaminated with Escherichia coli O157:H7 at refrigeration temperature. Ground beef was inoculated with 7 Log CFU/g of E. coli O157:H7 isolated from domestic pigs and was then subjected to ozone exposure ($10{\times}10^{-6}kg\;O_3h^{-1}$) at $4^{\circ}C$ for 3 d. E. coli O157:H7, total aerobic and anaerobic bacterial growth and oxidative properties including instrumental color changes, TBARS, catalase (CAT) and glutathione peroxidase (GPx) activity were evaluated. Ozone exposure significantly prohibited (p<0.05) the growths of E. coli O157:H7, total aerobic and anaerobic bacteria in ground beef samples during storage. Ozone exposure reduced (p<0.05) the CIE $a^*$ value of samples over storage time. The CIE $L^*$ and CIE $b^*$ values of the samples fluctuated over storage time, and ozone had no clear effect. Ozone exposure increased the TBARS values during 1 to 3 d of storage (p<0.05). The CAT and GPx enzyme activities were not affected by ozone exposure until 2 and 3 d of storage, respectively. This study provides information about the use of ozone exposure as an antimicrobial agent for meat under refrigerated storage. The results of this study provide a foundation for the further application of ozone exposure by integrating an ozone generator inside a refrigerator. Further studies regarding the ozone concentrations and exposure times are needed.

불소 도핑 이산화주석 박막의 수소플라즈마 내구성 (HYDROGEN PLASMA DURABILITY OF $SnO_2$:F FILMS)

  • 윤경훈;송진수;강기환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.847-849
    • /
    • 1992
  • Fluorine-doped ($SnO_2$:F) thin films obtained by pyrosol deposition method have been exposed to R.F. excited pure hydrogen plasma under the following conditions; substrate temperature of 200$^{\circ}C$, $H_2$ pressure of 1 Torr, R.F. input power of 50 mW/$\textrm{cm}^{2}$, $H_2$ flow rate of 30cc/min and exposure time of 15-600 seconds. It is found that the sheet resistance of the films remains unchanged or rather slightly reduces for initial exposure time of 30-60 seconds, but increases sharply with further increasing the exposure time. The optical transmittance of $SnO_2$:F films slows a rapid fall with increasing exposure time except for a film obtained with a solution having $CH_3OH/H_2O$ mol ratio of 2.65, its degradations at the exposure time of 30-60 seconds are about 7-15%. In addition, the exposure of the films to hydrogen plasma atmosphere leads to remarkable changes in the microstructure and chemical composition, which should be attributed to the reduction of $SnO_2$ to SnO and to elemental Sn.

  • PDF

Residual Stress on Concentric Laminated Fibrous Al2O3-ZrO2 Composites on Prolonged High Temperature Exposure

  • Sarkar, Swapan Kumar;Lee, Byong Taek
    • 한국재료학회지
    • /
    • 제23권9호
    • /
    • pp.531-536
    • /
    • 2013
  • This paper investigates the effect of prolonged high temperature exposure on concentric laminated $Al_2O_3-ZrO_2$ composites. An ultrafine scale microstructure with a cellular 7 layer concentric lamination with unidirectional alignment was fabricated by a multi-pass extrusion method. Each laminate in the microstructure was $2-3{\mu}m$ thick. An alternate lamina was composed of 75%$Al_2O_3$-(25%m-$ZrO_2$) and t-$ZrO_2$ ceramics. The composite was sintered at $1500^{\circ}C$ and subjected to $1450^{\circ}C$ temperature for 24 hours to 72 hours. We investigated the effect of long time high temperature exposure on the generation of residual stress and grain growth and their effect on the overall stability of the composites. The residual stress development and its subsequent effect on the microstructure with the edge cracking behavior mechanism were investigated. The residual stress in the concentric laminated microstructure causes extensive micro cracks in the t-$ZrO_2$ layer, despite the very thin laminate thickness. The material properties like Vickers hardness and fracture toughness were measured and evaluated along with the microstructure of the composites with prolonged high temperature exposure.

Statistical Modeling of the Pretilt Angle Control in Nematic Liquid Crystal using In-situ Photoalignment Method on Plastic Substrate

  • Kang, Hee-Jin;Lee, Jung-Hwan;Yun, Il-Gu;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권3호
    • /
    • pp.145-148
    • /
    • 2006
  • In this study, the response surface modeling of the pretilt angle control using in-situ photoalignment method with oblique UV exposure .on plastic substrate is investigated. The pretilt angle is the main factor to determine the alignment of the liquid crystal display. The response surface model is used to analyze the variation of the pretilt angle on the various process conditions. Heating temperature and UV exposure time are considered as input factors. The liquid crystal (LC) pretilt angle increased with increasing heating temperature and UV exposure time. The analysis of variance is used to analyze the statistical significance and the effect plots are also investigated to examine the relationship between the process parameters and the response.

플렉서블 CIGS 태양전지의 고온고습 환경 고장 기구 분석 (Evaluation of Failure Mechanism of Flexible CIGS Solar Cell Exposed to High Temperature and Humid Atmosphere)

  • 김혁수;변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권1호
    • /
    • pp.41-47
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate electrical and structural degradation of flexible CIGS sollar cell exposed to high temperature and humid atmosphere. Method: Accelerated degradation was performed for various time under $85^{\circ}C/85%RH$ and then electrical and structural properties were analyzed by 4-point probe method, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray diffraction (XRD). Results: Sheet resistance of the top ITO layer increased with exposure time to the high temperature and humid atmosphere. Blunting of the protrusion morphology of ITO layer was observed for the degraded specimen, while no phase change was detected by XRD. Oxygen was detected at the edge area after 300 hours of exposure. Conclusion: Increase in electrical resistance of the degraded CIGS solar cell under high temperature and humid environment was attribute to the oxygen or water absorption.

Anaesthetic Efficacy and Physiological Response of Clove Oil and Lidocaine-HCl on River Puffer, Takifugu obscurus and Tiger Puffer, T. rubripes

  • Park, In-Seok
    • 한국발생생물학회지:발생과생식
    • /
    • 제23권1호
    • /
    • pp.21-34
    • /
    • 2019
  • The effects of the anaesthetic agents, clove oil and mixture of clove oil with lidocaine-HCl were evaluated on river puffer, Takifugu obscurus and tiger puffer, T. rubripes. Anaesthesia times of clove oil were affected by water temperature ($20^{\circ}C$, $24^{\circ}C$, and $28^{\circ}C$) and salinity (10, 20, and 30 ppt). Anaesthesia times of mixed samples were significantly similar with regard to exposure and recovery times, and all samples satisfied anaesthesia criteria (exposure time within 3 min and recovery time within 5 min) under the various temperatures and salinities, and the lowest to highest concentration of anaesthetics (p<0.05). Both species river puffer and tiger puffer had short exposure time with a high anaesthesia dose, high temperature ($28^{\circ}C$) and intermediate salinity (20 ppt), and were highly affected by temperature and salinity (p<0.05). The mixed anaesthetics had rapid exposure times and long recovery times in contrast to the effects of clove oil. Cortisol concentrations under the conditions of various clove oil dosages, salinity, and temperature for both species increased until 12 hrs after recovery from anaesthesia (p<0.05). After 12 hrs, cortisol concentrations decreased until after 48 hrs (p<0.05). During the simulated transportation of both species, control and sedated clove oil groups (5 ppm) were measured for water parameters, dissolved oxygen (DO), $CO_2$, respiratory frequency, $NH_4{^+}$, and pH for 6 hrs in 1 hr intervals. Water parameters of sedated groups and controls were significantly different after 2 hrs (p<0.05).

Microplastic release from damaged commercial teabags

  • Kim, Sion;Jo, Eun Ha;Choi, Soohoon
    • Membrane and Water Treatment
    • /
    • 제13권1호
    • /
    • pp.21-28
    • /
    • 2022
  • The use of plastics in our everyday lives have been drastically increased during the last few decades. However with the usage of commercial plastic products there is a possibility of microplastic consumption, due to the fragmentation of the products. Additionally, the potential for microplastic ingestion may also be increased by using damaged products. Hence, the current study was conducted to understand the potential release of micro/nano plastics and organic matter from damaged teabags. To check the leakage tendency, the amount of damage to the tea bags from 1-10 cm were tested along with temperatures of 25-70℃, and exposure times from 5 min to 1 hr was tested. Release of fibrous micro/nanoplastics, and organic leachate from the damaged teabags were observed to understand the outflow conditions. Results showed that with the increased degree of damage, temperature, and exposure time increased the release of fiberous matter, where the increase of temperature, and exposure time increased organic leachate. Additional analysis confirmed the leachate of nylon polymers into the heated water.

기온 70℃의 복사열 노출 환경에서 건조와 젖은 상태의 소방용 보호장갑 착용 시 쾌적성 평가 (Wear Comfort of Firefighters Protective Gloves in Dry and Wet Conditions at 70℃ Air Temperature with Radiant Heat)

  • 김다미;김도형;이주영
    • 한국생활환경학회지
    • /
    • 제24권1호
    • /
    • pp.95-106
    • /
    • 2017
  • The purpose of this study was to evaluate comfort functions while wearing firefighters' protective gloves in dry and wet conditions at $70^{\circ}C$ air temperature with radiant heat. Four types of firefighting gloves from Korea, Germany, United States, and Japan were evaluated in both dry and wet conditions by eight male firefighters. Firefighters put their hands and forearms wearing gloves into a hands-radiant chamber that maintained at an air temperature of $70{\pm}2^{\circ}C$ ($T_a$) and globe temperature $106^{\circ}C$ ($T_g$). During the exposure, subjects followed a fixed protocol of manual movements and stopped the exposure when they felt being intolerable. Results showed that completion time was extended by 6 min on average when gloves got wet and 15 min for the Japanese gloves was extended when compared to its dry condition (p<.001); microclimate humidity on the palm at the last stage was greater for wet conditions than dry conditions in the all gloves; and skin temperatures on mid-fingertip, palm, and hand were significantly lower for wet conditions than dry conditions especially for Japanese gloves (p<.001). These results indicate that the exposure time without thermal pain to radiant heat could be extended by wetting gloves during the low radiant heat exposure.