• 제목/요약/키워드: experimental facility

검색결과 757건 처리시간 0.028초

단말뚝 거동에 관한 원심모형실험 (Centrifuge Model Experiments on Behaviors of Single Pile)

  • 유남재;이명욱;이종호
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.111-118
    • /
    • 1997
  • This thesis is an experimental research of investigating behavior of single pile, subjected to the vertical compression loads, using the centrifuge facility located in the geotechnical engineering laboratory in Kangwon National University. Centrifugal model experiments of model pile were carried out changing diameter of model pile, relative density of sandy ground and the gravitational level applied in the centrifuge. Thus, their effects on the load-settlement behavior and the ultimate bearing capacity of pile were investigated. Experimental results obtained from centrifuge model tests were compared with the theoretical or semi-empirical equations to analyze values of ultimate bearing capacity of model pile. When we compare the ultimate bearing capacity of experimental results with the ultimate bearing capacity of theorical results, the experimental results appear more higher in the De Beer method and Meyerhof. Expecially, Terzaghi method is very same as the experimental results normally.

  • PDF

간접가온 건조방식의 건조시설을 이용한 하수슬러지 퇴비화에 관한 연구 (Research on composting of sewage sludge using dryer facility with indirect heating system)

  • 백선재;한인섭;최익훈;강성효;홍성민
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.299-304
    • /
    • 2014
  • The need of reusing sewage sludge is highly increasing as the amount of domestic sewage sludge is growing and sewage management strategies were reinforced. Accordingly, in this research, we studied the composting possibility of sludge in sewage treatment plant J, using dryer facility with indirect system by conducting component analysis of dried sludge and experiment on cultivating crops. It was observed from the component analysis, that the dried sludge is appropriate for both decomposed manure standard of Ministry of Environment and fertilizer standard of Rural Development Administration. Besides, in the experiment on cultivating lettuce, the experimental group(soil + dried sludge) was superior to the control group(soil + bed soil) in apparent condition of leaves tensity and damage by disease and pest. In case of cultivating tomato, the experimental group showed stronger durability of fruits dangling on stems compared to the control group after 9 weeks. Consequently, the excess sludge dried by indirect heating system in the sewage treatment plant J is appropriate for the standard of both Ministry of Environment and Rural Development Administration and show good result in experiment on cultivating crops therefore it can be reused for composting.

내화용 오일붐의 내화성에 대한 실험적 연구 (An Experimental Study on Fire-Resistant Boom)

  • 유정석;성홍근;오준헌
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제3권2호
    • /
    • pp.25-32
    • /
    • 2000
  • 내화용 오일붐은 해상누유사고시 누유현장소각기술에 있어서 핵심적인 방제장비이다. 본 논문에서는 내화용 오일붐의 성능평가기법으로 전기로시험과 수조시험을 제안하였다. 전기로시험에는 내화용 재질의 내화성을 평가하며, 수조시험에서는 실제 현장소각시에 화염에 노출된 내화용 오일붐의 상태를 최대한 모사하였다. 수조시험장비는 유조, 내화용 오일붐 모형, 연소가스 흡입을 위한 후드, 소각로와 온도계 등으로 구성된다. 본 연구에서 개발된 내화용 오일붐에 대하여 성능평가를 수행한 결과, 화염온도 800℃에 대하여 견딜 수 있음을 확인할 수 있었다. 본 연구의 성능평가기법이 실제 해상에서 사용할 수 있는 내화용 오일붐에 대하여 적용할 수 있기 위해서는 보다 더 높은 측도의 시험시설 및 장시간의 실험이 요구된다.

  • PDF

Comparison of Rectal and Infrared Thermometry for Obtaining Body Temperature of Gnotobiotic Piglets in Conventional Portable Germ Free Facility

  • Chung, Tae-Ho;Jung, Woo-Sung;Nam, Eui-Hwa;Kim, Ji-Hyun;Park, Seol-Hee;Hwang, Cheol-Yong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권10호
    • /
    • pp.1364-1368
    • /
    • 2010
  • Gnotobiotic piglets (n = 10) were hand-reared in conventional germ-free facilities. Piglet body temperatures were measured with rectal and non-contact infrared thermometry (NIFT) on the lower eyelid, auricular center and margin, parietal regions, axilla, central abdomen and dorsum, and the perianal region. Body temperature measurements at central abdomen, cranial dorsum, and perianal regions had NIFT values which had a significant linear relationship (p<0.0001) with rectal thermometry. The predicted equations of between-subject formulas were calculated as follows: rectal temperature, 28.07489+0.30372${\times}$central abdominal surface temperature; rectal temperature, 34.02799+0.15197${\times}$central dorsum surface temperature; and rectal temperature, 33.87937+0.15676${\times}$perianal temperature. These results suggested that NIFT could serve as a valid alternative to rectal thermometry in a portable germ-free facility without disturbing experimental animals. The development of a NIFT body temperature evaluation that does not require animal restraint is clinically advantageous, particularly in gnotobiotic piglets, and would be significantly less stressful for experimental procedures in germ-free facilities.

재순환에 의한 흡수성 바이오필터 시스템의 오수처리효율 향상 (Enhancement of Sewage Treatment Efficiencies by Recirculation in Absorbent Biofilter System)

  • 권순국;전기설;김성배
    • 한국농공학회논문집
    • /
    • 제47권3호
    • /
    • pp.69-76
    • /
    • 2005
  • An Absorbent Biofilter System (ABS) combined with the recirculation process was investigated for the feasible application in additional removing of organics (BOD, SS) as well as nutrients (TN, TP) from small Community wastewater in Korea. Polyurethane biofilter media with high porosity and large surface area were /used for the aerobic system. A part of treated wastewater was recirculated into the anoxic septic tank to promote removal of nutrients. The concentrations of BOD and SS of treated wastewater satisfied the regulations for small on-site wastewater treatment facility (10 mg/L) during the overall experimental period. The effluent concentrations of BOD and SS were decreased with enhancement of removal efficiencies of 95.7 and $96.7\%$. The nitrogen and phosphorus removal efficiencies by the recirculation increased to $52.9\%\;and\;43.2\%$ in average during the overall experimental period, respectively. With the improvement, these values were increased as much as additional 42 and $18\%$ compared with those of non-recirculation. The rates of nitrification and denitrification were enhanced showing $65\~77\%\;and\;42\~92\%$, respectively. The described process modification is a low cost and effective method of enhancing nitrogen and phosphorus removal, especially on existing systems without changing major design components of a treatment facility.

Modeling of neutron diffractometry facility of Tehran Research Reactor using Vitess 3.3a and MCNPX codes

  • Gholamzadeh, Z.;Bavarnegin, E.;Rachti, M.Lamehi;Mirvakili, S.M.;Dastjerdi, M.H.Choopan;Ghods, H.;Jozvaziri, A.;Hosseini, M.
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.151-158
    • /
    • 2018
  • The neutron powder diffractometer (NPD) is used to study a variety of technologically important and scientifically driven materials such as superconductors, multiferroics, catalysts, alloys, ceramics, cements, colossal magnetoresistance perovskites, magnets, thermoelectrics, zeolites, pharmaceuticals, etc. Monte Carlo-based codes are powerful tools to evaluate the neutronic behavior of the NPD. In the present study, MCNPX 2.6.0 and Vitess 3.3a codes were applied to simulate NPD facilities, which could be equipped with different optic devices such as pyrolytic graphite or neutron chopper. So, the Monte Carlo-based codes were used to simulate the NPD facility of the 5 MW Tehran Research Reactor. The simulation results were compared to the experimental data. The theoretical results showed good conformity to experimental data, which indicates acceptable performance of the Vitess 3.3a code in the neutron optic section of calculations. Another extracted result of this work shows that application of neutron chopper instead of monochromator could be efficient to keep neutron flux intensity higher than $10^6n/s/cm^2$ at sample position.

Post Test Analysis to Natural Circulation Experiment on the BETHSY Facility Using the MARS 1.4 Code

  • Chung, Young-Jong;Kim, Hee-Cheol;Chang, Moon-Hee
    • Nuclear Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.638-651
    • /
    • 2001
  • The present study is to assess the applicability of the best-estimate thermal-hydraulic code, MARS 1.4, for the analysis of thermal-hydraulic behavior in PWRs during natural circulation conditions. The code simulates a natural circulation test, BETHSY test 4. la, which was conducted on the integral test facility of BETHSY. The test represented the cooling states of the primary cooling system under single-phase natural circulation, two-phase natural circulation and the reflux condensation mode with conditions corresponding to the residual power, 2% of the rated core power value and 6.8 MPa at the secondary system. Based on MARS 1.4 calculations, the major thermal-hydraulic behaviors during natural circulation are evaluated and the differences between the experimental data and calculated results are identified. The calculated results show generally good behavior with regard to the experimental results; the region of single-phase natural circulation is 100-92% of the initial mass inventory, two-phase natural circulation is 84-63 %, and the reflux condensation mode occurred below 58 %. U-tubes empty and the core uncovery are obtained at 39 % and 34 % of the initial mass inventory, respectively.

  • PDF

바닥 난방공간의 다인자 제어에 관한 실험적 연구 (An experimental study on the multiple parameter switching control for floor heating system)

  • 조성환;태춘섭;장철용
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

원자력발전소에서의 인간공학적 실험평가를 위한 종합 실험설비 개발 (Development of integrated test facility for human factors experiments in nuclear power plant)

  • 오인석;이현철;천세우;박근옥;심봉식
    • 대한인간공학회지
    • /
    • 제16권1호
    • /
    • pp.107-117
    • /
    • 1997
  • It is necessary to evaluate HMI inaspects of human factors in the design stage of MMIS(man machine interface system) and feedback the result of evaluation because operators performance is mainly influenced by the HMI. Therefore, the MMIS design should be reflected the operators psychological, behavioral and physiological characteristics in the interaction with human machine interface(HMI) in order to improve the safety and availability of the MMIS of a nuclear power plant(NPP) by reduction of human error. The development of human factors experimental evaluation techniques and integrated test facility(ITF) for the human factors evaluation become an important research field to resolve hi,am factors issues on the design of an advanced control room(ACR). We developed am ITF, which is aimed to experiment with the design of the ACR and the human machine interaction as it relates to the control of NPP. This paper presents the development of an ITF that consists of three rooms such as main test room(MTR), supporting test room(STR) and experiment control room(ECR). And, the ITF has a various facilities such as a human machine simulator(HMS), experimental measurement systems and data analysis and experiment evaluation supporting system(DAEXESS). The HMS consists of full-scope simulation model of Korean standard NPP and advanced HMI based on visual display nits (VDUS) such as touch color CRT, large scale display panel(LSDP), flat panel display unit and so on.

  • PDF