• 제목/요약/키워드: excitation circuit

검색결과 145건 처리시간 0.044초

단락발전기 용 여자장치의 조작과 기능에 대한 고찰 (The study for function and operation of the excitation equipment for short circuit generator)

  • 김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.735-736
    • /
    • 2008
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, CLR, Back Up Breaker, Making Switch and Excitation Equipment etc. Gradually an allowable tolerance of the short circuit test voltage is become smaller by the standards for short circuit test. The excitation equipment of short circuit generator is very important for test voltage is adjusted by the excitation equipment. Especially the excitation equipment must be possessed character of exactitude, durability and inalterability because some times around 10,000 times opening and closing short circuit test is requested by clint, which must be done within one minute. The purpose of this study for function and operation of the excitation equipment which rated DC voltage is 1,000V, rated DC current is 300A, rated out put is 30kW and type is YNEX 97S-441/609, is to help operation of short circuit generator.

  • PDF

Realistic Circuit Model of an Impact-Based Piezoelectric Energy Harvester

  • Kim, Sunhee;Ju, Suna;Ji, Chang-Hyeon;Lee, Seungjun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권5호
    • /
    • pp.463-469
    • /
    • 2015
  • A vibration-based energy harvester and its equivalent circuit models have been reported. Most models predict voltage signals at harmonic excitation. However, vibrations in a natural environment are unpredictable in frequency and amplitude. In this paper, we propose a realistic equivalent circuit model of a frequency-up-converting impact-based piezoelectric energy harvester. It can describe the behavior of the harvester in a real environment where the frequency and the amplitude of the excitation vary arbitrarily. The simulation results of the model were compared with experimental data and showed good agreement. The proposed model can predict both the impact response and long term response in a non-harmonic excitation. The model is also very useful to analyze the performance of energy conversion circuitry with the harvester.

500MVA 단락발전기 여자시스템 특성 개선에 관한 고찰 (A study of excitation system of 500MVA short-circuit facilities)

  • 정흥수;나대열;김선구;노창일;김원만;이동준;김선호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.685-686
    • /
    • 2006
  • The excitation system of 500MVA short-circuit generator is very important because of operation of various condition, for example, (over) load switching, short-time current, short-circuit current, etc. This paper introduces a feature of excitation system of 500MVA short-circuit facilities and the function and construction of each part.

  • PDF

500MVA급 단락발전기 여자시스템의 특성개선 (A study of excitation system of 500MVA short-circuit generator)

  • 정흥수;김선구;노창일;김원만;이동준;김선호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.989-990
    • /
    • 2007
  • The excitation system of 500 MVA short-circuit generator is very important because of operation of various condition, for example, (over) load switching, short-time withstand current, short-circuit making and breaking current, etc. This paper introduces a feature of excitation system of 500MVA short-circuit generator and the function and construction.

  • PDF

A Study on the Modeling and Design of Single Phase Induction Generators

  • Kim Cherl-Jin;Lee Kwan-Yong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.331-336
    • /
    • 2005
  • With increasing emphasis on non-conventional energy systems and autonomous power generation, development of improved and appropriate generating systems has recently taken on greater significance. This paper describes the performance analysis of a single phase self-excited induction generator (SEIG), suitable for autonomous/standby power systems. The system is also appropriate for wind energy systems and small portable systems. Both windings of the induction machine, the main and the auxiliary, are utilized. One winding will be devoted to the supply excitation current only, by being connected to the excitation capacitor, while the load is connected across the other winding. As the design of excitation, the minimum of self-excited capacitor connected auxiliary winding is determined as the suitable value using a circuit equation of auxiliary winding. For the steady state analysis, the equivalent circuit of the single-phase induction generators is used as a basis for modeling using the double-revolving field theory. The validity of the designed generator system is confirmed by experimental and computed results.

여자전류 재단에 따른 단락 시험용 변압기의 절연영향 평가 (Estimating the Effect of Overvoltage Results from Excitation Current Chopping in Short-circuit Transformer)

  • 오승렬;박지훈;박종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.78-80
    • /
    • 2007
  • The residual flux in transformer's iron cores leads to a distortion of short-circuit current occasionally. And some considerable distortion may have effect on the validation of the test results. To avoid the substantial distortion, a suitable pretest is performed before the actual test. In case of applying this method there must be excessive overvoltage due to switching of an unloaded transformer and chopping of an excitation current. The purpose of this paper is estimate that the effect of the overvoltage results from this phenomenon on insulation performance of short-circuit transformer.

  • PDF

PMG Type 디지털 AVR을 이용한 선박용 동기발전기 출력전압제어 (Voltage Control of Synchronous Generator for Ships using a PMG Type Digital Automatic Voltage Regulator)

  • 유동환;박상훈;원충연;유재성;이상석;안성준
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.38-45
    • /
    • 2009
  • 일정 출력을 얻기 위해 동기발전기 계자 여자는 AVR에 의해 제어된다. 대부분의 선박용 동기발전기 AVR은 사이리스터 위상제어 방식을 사용한다. 하지만 이 방식은 제어 주기가 MOSFET이나 IGBT로 구성된 컨버터에 비해 느리므로 속응 제어를 구현하는데 어려움이 있다. 따라서 본 논문에서는 선박용 동기발전기에 MOSFET을 사용한 PMG형 디지털 AVR을 구현하였다. PMG형 디지털 AVR 회로 구성은 간단하고 단락 시 발전기 출력전압이 영으로 되어 AVR이 동작하지 못하므로 출력전류를 여자회로로 흐르도록 하는 CBC가 요구된다. 본 논문에서 연구된 여자 시스템은 실제 선박용 발전기를 대신하여 10[kVA]급 프로토타입의 실험을 통하여 시스템의 타당성을 검증하였다.

벡터제어에 의한 자립식 유도발전기의 여자특성 해석 (Excitation Characteristics Analysis of an Isolated Induction Generator by applying Vector Control)

  • 이규민;구태만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.896-898
    • /
    • 2004
  • The lagging reactive power should be supplied for the excitation of isolated squirrel-cage induction generators by external circuit. This paper deals with a technique to drive the equations for analysis of the excitation characteristics and performance of an isolated squirrel-cage induction generator from the conventional equivalent circuit of induction machine, transform the equations into d-q coordinates to use vector control technique, and carry out the simulation of an induction generator system with various conditions using MATLAB. The results of the simulation indicate that moderate reactive power can be controlled effectively to maintain constant voltage over a wide range of the rotor speeds and loads.

  • PDF

복소유전률 측정장치의 연구개발 - 컴퓨터제어 복소유전률 측정장치 - (A study on the computer-controlled measuring device of complex dielectric constant)

  • 남징락;엄상오;강대하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1206-1208
    • /
    • 1993
  • This paper is to study and realize a measuring device for complex dielectric constants. The device is consisted in order of interface unit, external RAM, programmable counter, D/A converter, measuring circuit, Sample & Hold circuit, A/D converter and related control circuits. Various excitation waves are digitalized and sent to the 4096 static RAM by personal computer. These data saved in the RAM are converted to analog excitation waves through D/A converter. The frequency of excitation wave is depend on the read-out speed of the RAM according to clock pulses. Such generated waves are applied to dielectrics under test and their responses are sampled and converted to digital data through A/D converter. The computer takes the digital data and calculates finally the complex dielectric constants. The frequencies for Measurement ranges from 0.04 Hz to 10 kHz.

  • PDF

인천화력 4호기 발전기용 주/부 제어기를 갖는 정지형 여자시스템 개발 (Development of Generator Excitation System with Main/Standby Controller in In-chun Thermal power plant #4)

  • 류호선;임익헌
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.407-410
    • /
    • 1999
  • Potential-source controlled excitation system had been developed for synchronous generator in In-Chun thermal power plant #4 by KEPRI. This paper describes the characteristics of Main/Standby control system employed analog, digital circuit devices (hybrid type) and 3 PCRs(Phase Controlled Rectifier)

  • PDF