• Title/Summary/Keyword: evaporation characteristics

Search Result 926, Processing Time 0.031 seconds

An Analytical Study on the Heat Transfer Characteristics of MF Evaporation Tubes Attached with a Fin (핀이 부착된 MF증발관의 열전달 특성에 대한 해석적 연구)

  • Park, Yong-Seok;Seong, Hong-Seok;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.1
    • /
    • pp.48-56
    • /
    • 2021
  • In this study, the heat transfer process around the finned channel tubes is numerically examined. Serially arranged tubes of an evaporator were used for heat exchange. The numerical analysis results confirmed that the vortex generated at the rear of the channel pipe was caused by the fin. Furthermore, it was also confirmed that the temperature difference was large between the inlet and outlet ends of the fin. The temperature of the location where the fin was attached to the channel pipe was found to be close to the surface temperature of the channel wall. However, the temperature rose rapidly closer to the ambient air temperature of 350 K towards the fin end, located at a distance of 0.035 m; it was found to have a significant influence on the heat transfer around the fin-attached channel tube. The wider the vertical flow path, the lower the total heat transfer coefficient. However, the overall heat transfer coefficient increased as the horizontal flow path narrowed. The increment is attributed to an increase in the heat transfer amount due to increased heat transfer surface.

Investigating the role of nano in preserving the environment with new energy and preventing oil pollution

  • Yong Huang;Lei Zhang
    • Advances in nano research
    • /
    • v.15 no.6
    • /
    • pp.541-550
    • /
    • 2023
  • The escalating growth of industrial sectors has led to a pervasive global problem—oil pollution, particularly in industrial areas. The release of substantial volumes of oil and its by-products into the environment has resulted in extensive contamination. Multiple factors contribute to the entry of these substances into water bodies and soils, thereby inflicting irreparable consequences on ecosystems, natural resources, and human health. Consequently, it becomes imperative to comprehend the characteristics and behavior of oil pollution, anticipate its impacts, and develop effective mitigation strategies. Understanding this intricate issue requires considering the physicochemical properties of the environment, the interactions between oil and sediments, and biological factors such as evaporation and dissolution. Although the oil industry has brought about remarkable advancements, its activities have raised significant concerns regarding pollution from extraction and production processes. Oil-rich nations face a particularly challenging predicament of soil pollution caused by petroleum compounds. The areas surrounding oil exploration mines and refineries often endure contamination due to oil leakages from storage tanks and transmission lines resulting from deterioration and damage. Investigating the dispersion of such pollutants and devising methods to remediate petroleum-contaminated soil represent crucial and intricate issues within the realm of environmental geotechnics.

Capacitor Failure Detection Technique for Microgrid Power Converter (마이크로그리드 전력변환장치용 커패시터 고장 검출 기법)

  • Woo-Hyun Lee;Gyang-Cheol Song;Jun-Jae An;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1117-1125
    • /
    • 2023
  • The DC part of the DC microgrid power conversion system uses capacitors for buffers of charge and discharge energy for smoothing voltage and plays important roles such as high frequency component absorption, power balancing, and voltage ripple reduction. The capacitor uses an aluminum electrolytic capacitor, which has advantages of capacity, low price, and relatively fast charging/discharging characteristics. Aluminum electrolytic capacitors(AEC) have previous advantages, but over time, the capacity of the capacitors decreases due to deterioration and an increase in internal temperature, resulting in a decrease in use efficiency or an accident such as steam extraction due to electrolyte evaporation. It is necessary to take measures to prevent accidents because the failure diagnosis and detection of such capacitors are a very important part of the long-term operation, safety of use, and reliability of the power conversion system because the failure of the capacitor leads to not only a single problem but also a short circuit accident of the power conversion system.

Release Behavior and Characterization of PCL Microcapsules Containing Lemongrass Oil (레몬그라스 오일을 함유하는 PCL마이크로캡슐의 특성과 방출거동)

  • Park, Jong-Kwon;Kim, Ji-Eun;Jeong, Noh-Hee
    • Applied Chemistry for Engineering
    • /
    • v.26 no.3
    • /
    • pp.341-346
    • /
    • 2015
  • In this study, poly ${\varepsilon}$-caprolactone(PCL) microcapsules containing lemongrass oil was prepared by the solvent evaporation method. Effects of concentrations of PCL and poly vinyl alcohol (PVA) as well as stirring speeds when preparing microcapsules were investigated. Specific peaks of lemongrass oil in PCL microcapsules at 1600 and $2900cm^{-1}$ were observed by FT-IR. The particle size and shape of microcapsules were also measured by polarizing microscope and optical microscopy. The average particle size of microcapsules decreased with increasing the stirring rate. At the stirring speed of 1500 rpm, and 1 wt% of each PCL and PVA concentrations, the smallest particles were formed. Collection efficiencies of lemongrass oil of 77.5% and 69.5% were obtained when 1.5 wt% of PCL and 2 wt% of PVA were used, respectively. In addition, the release behavior and antioxidant activity of lemongrass oil from PCL microcapsules were examined using UV-Vis spectrophotometry. When 0.5 wt% PCL and 2.0 wt% PVA were used with the slow stirring rate, microcapsules showed a fast release rate. The characteristics of antioxidant activity exhibited similar to that of the release behavior.

Effect of compliance current on resistive switching characteristics of solution-processed HfOx-based resistive switching RAM (ReRAM)

  • Jeong, Ha-Dong;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.255-255
    • /
    • 2016
  • Resistive random access memory (ReRAM)는 낮은 동작 전압, 빠른 동작 속도, 고집적화 등의 장점으로 인해 차세대 비휘발성 메모리 소자로써 많은 관심을 받고 있다. 최근에 ReRAM 절연막으로 NiOx, TiOx, AlOx TaOx, HfOx와 같은 binary metal oxide 물질들을 적용하는 연구가 활발히 진행되고 있다. 특히, HfOx는 안정적인 동작 특성을 나타낸다는 점에서 ReRAM 절연막 물질로 적합하다고 보고되고 있다. ReRAM 절연막을 형성할 때, 물리 기상 증착 방법 (PVD)이나 화학 기상 증착법 (CVD)과 같은 방법이 많이 이용된다. 이러한 증착 방법들은 고품질의 박막을 형성시킬 수 있는 장점이 있다. 하지만, 높은 온도에서의 공정과 고가의 진공 장비가 이용되기 때문에 경제적인 문제가 있으며, 기판 또는 금속에 플라즈마 손상으로 인한 문제가 발생할 수 있다. 따라서 이러한 문제점들을 개선하기 위해 용액 공정이 많은 관심을 받고 있다. 용액 공정은 공정과정이 간단할 뿐만 아니라 소자의 대면적화가 가능하고 공정온도가 낮으며 고가의 진공장비가 필요하지 않은 장점을 가진다. 따라서 본 연구에서는, 용액공정을 이용하여 HfOx 기반의 ReRAM 제작하였고 $25^{\circ}C$$85^{\circ}C$에서 ReRAM의 동작특성에 미치는 compliance current의 영향을 평가하였다. 실험 방법으로는, hafnium chloride (0.1 M)를 2-methoxyethanol에 충분히 용해시켜서 precursor를 제작하였다. 이후, p-type Si 기판 위에 습식산화를 통하여 300 nm 두께의 SiO2 절연층을 성장시킨 후, 하부전극을 형성하기 위해 electron beam evaporation을 이용하여 10/100 nm 두께의 Ti/Pt 전극을 증착하였다. 순차적으로, 제작된 산화물 precursor를 이용하여 Pt 위에 spin coating 방법으로 1000 rpm 10 초, 6000 rpm 30초의 조건으로 두께 35 nm의 HfOx 막을 증착하였다. 최종적으로, solvent 및 불순물을 제거하기 위해 $180^{\circ}C$의 온도에서 10 분 동안 열처리를 진행하였으며, 상부 전극을 형성하기 위해 electron beam evaporation을 이용하여 Ti와 Al을 각각 50 nm, 100 nm의 두께로 증착하였다. ReRAM 동작에서 compliance current가 미치는 영향을 평가하기 위하여 compliance current를 10mA에서 1mA까지 변화시키면서 측정한 결과, $25^{\circ}C$에서는 compliance current의 크기와 상관없이 일정한 메모리 윈도우와 우수한 endurance 특성을 얻는 것을 확인하였다. 한편, $85^{\circ}C$의 고온에서 측정한 경우에는 1mA의 compliance current를 적용하였을 때, $25^{\circ}C$에서 측정된 메모리 윈도우 크기를 비슷하게 유지하면서 더 우수한 endurance 특성을 얻는 것을 확인하였다. 결과적으로, 용액공정 방법으로 제작된 ReRAM을 측정하는데 있어서 compliance current를 줄이면 보다 우수한 endurance 특성을 얻을 수 있으며, ReRAM 소자의 전력소비감소에 효과적이라고 기대된다.

  • PDF

Development of the Dryer with a Heat Source of Carbon Nanofibers (탄소나노섬유를 열원으로 적용한 세탁물 건조기의 개발)

  • Lee, Jung-Hwan;Won, Sang-Yeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.3
    • /
    • pp.25-34
    • /
    • 2018
  • This paper presents a heating source of carbon nanofibers for the efficiency and the drying performance of laundry dryer, and focuses on the applicability-evaluation of its source. To design the proposed heating module, experiments were conducted in terms of surface temperature and surface temperature distribution characteristics of carbon nanofiber lamps. The surface temperature of the lamps increased linearly with increment of a current to flow a lamp and revealing the increasing pattern as the length of the ramps is shorter. The proposed heating source was evaluated based on drying efficiency, moisture evaporation rate at laundry, and internal temperature of a drum during drying process. The drying efficiency satisfied a 45% which is specified in KS C 9319. The moisture evaporation rate and the internal temperature of the drum were respectively 98.88% and $61.1^{\circ}C$, which are similar to that of S's company dryer. From the evaluation and actual drying test results, the proposed carbon nanofiber lamp heating module is considered to be applicable as a heat source for laundry dryer in terms of drying efficiency and drying performance. it is possible to obtain a heat source at a high temperature, an excellent calorific value, an improvement in drying performance, and an effect of sterilizing laundry due to the emission of far-infrared rays. In addition to the applicability, the difference of the drying efficiency between the dryers was analyzed in detail based on the power consumption of the heat sources.

Characteristics of Greenup and Senescence for Evapotranspiration in Gyeongan Watershed Using Landsat Imagery (Landsat 인공위성 이미지를 이용한 경안천 유역 증발산의 생장기와 휴면기 분포 특성 분석)

  • Choi, Minha;Hwang, Kyotaek;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1B
    • /
    • pp.29-36
    • /
    • 2011
  • Evapotranspiration (ET) from the various surfaces needs to be understood because it is a crucial hydrological factor to grasp interaction between the land surface and the atmosphere. A traditional way of estimating it, which is calculating it empirically using lysimeter and pan evaporation observations, has a limitation that the measurements represent only point values. However, these measurements cannot describe ET because it is easily affected by outer circumstances. Thus, remote sensing technology was applied to estimate spatial distribution of ET. In this study, we estimated major components of energy balance method (i.e. net radiation flux, soil heat flux, sensible heat flux, and latent heat flux) and ET as a map using Mapping Evapo-Transpiration with Internalized Calibration (METRIC) satellite-based image processing model. This model was run using Landsat imagery of Gyeongan watershed in Korea on Feb 1, 2003 and Sep 13, 2006. Basic statistical analyses were also conducted. The estimated mean daily ETs had respectively 22% and 11% of errors with pan evaporation data acquired from the Suwon Weather Station. This result represented similar distribution compared with previous studies and confirmed that the METRIC algorithm had high reliability in the watershed. In addition, ET distribution of each land use type was separately examined. As a result, it was identified that vegetation density had dominant impacts on distribution of ET. Seasonally, ET in a growing season represented significantly higher than in a dormant season due to more active transpiration. The ET maps will be useful to analyze how ET behaves along with the circumstantial conditions; land cover classification, vegetation density, elevation, topography.

Study on the performance characteristics of a new CO2 auto-cascade heat pump system (새로운 CO2 오토 캐스케이드 열펌프 시스템의 성능특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.191-196
    • /
    • 2017
  • Owing to the harmful environmental effects of HCFC and CFC refrigerants discovered in the late 20th century, the need for environmentally friendly refrigerants such as $CO_2$ in cooling systems has increased. Air-source $CO_2$ heat pumps that utilize ambient heat in cold winter are less efficient because of a higher evaporation temperature, and it is difficult to manufacture the components of the heat pump owing to a super critical pressure of over 130 bar. This research aims to overcome these disadvantages and improve energy efficiency by introducing a new lower-pressure $CO_2$ auto-cascade heat pump system. $CO_2$-R32 zeotropic refrigerants were considered for two-stage expansion and effective cooling heat exchanging system configurations of the new auto-cascade heat pump. The results indicated that the efficiency of the two-stage expansion system was higher than that of the original one-stage expansion system. Furthermore, the two-stage expansion system showed significant performance improvements when the two-stage expansion stage from highest pressure of 70bar, intermediate expansion pressure of 25bar, and final low pressure of 10bar is applied. The COP of the new two-stage auto-cascade system (2.332) was 43.15% higher than that of the present simple auto-cascade system (1.629). Refrigerants having an evaporation temperature of $-10^{\circ}C$ or lower can be obtained that can be easily evaporated in an evaporator even at a low temperature.

A Study to Determine the Consumptive Use of Water for Upland Crops (전작물의 필요수량 결정을 위한 연구)

  • 김철회;유시창;이근후;서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.3
    • /
    • pp.37-45
    • /
    • 1980
  • This study was carried out to investigate the consumptive use of water for red peppers and soy beans. The correlation between the soil moisture contents and the selected meteorological factors during the growing season was analyzed. Characteristics of the drought at Jinju, Yeosu, Gwangju, and Mokpo area were figured out in view of frequency analysis. The results obtained from this study could be used as a reasonable criteria for the estimation of the duty of water in the design of upland irrigation systems. Obtained results are summarized as follows: 1. Red peppers were grown at the three levels of soil moisture contents; 75 percent, 50 percent, and 25 percent, respectively. The red pepper grown at the 75 percent of soil moisture content showed the highest yield. The total evapotranspiration during the growing season from red peppers was 471. lmm, which was 86.6mm less than the pan evaporation. 2. The soy bean grown at 75 percent soil moisture content showed the highest yield, although there was no signicant difference in yields among treatments. The total evapotranspiration during the growing season from the soy bean was 342.8 mm, which was 119.2mm less than the pan evaporation. 3. Coefficients of consumptive use(k) and meteorological data are shown on Table-9. 4. The significant correlations between the evapotranspiration and the humidity and daily temperature range were observed. Results are shown on Table-11.. Evaporanspiration can be easily estimated from the humidity and daily temperature range by using the equation...... (1) Ept=4.808-0.041H+0.207T.......(1) where, Ept; evapotranspiration(mm/day) H ; humidity(%) T ; daily temperature range ($^{\circ}C$) 5. The variations of soil moisture content during the growing season at the soil depth of 5cm, 15cm, and 45cm are shown on Fig. 4~9. The results of the correlation analysis between the evapotranspiration from the crops and the soil moisture content are shown on Table-12. The evapotranspiration can be estimated from soil moisture content at the different depth of the soil by using the equation....... (2). Ept = 3.433 - 0. 364M1 +0. 359M$_2$- 0. 055M$_3$....... (2) where, Ept; evapotranspiration (mm/day) M1 soil moisture meter reading at 5cm depth M$_2$; " 15cm " M$_2$; " 40cm " 6. The estimated probab]e successive dry days in selected areas are shown on Table 13. Gumbel-Chow method was used to calculate the probable successive dry days. Further investigation are required to obtain the more detailed and reliable results.

  • PDF

The Effect of Biodiesel Blend Fuels As Reductants on NOx Conversion Efficiency of HC_SCR (환원제로서 바이오디젤 혼합연료가 HC-SCR의 NOx 변환효율에 미치는 영향 연구)

  • Song, Hoyoung;Lee, Minho;Kim, Kiho
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.140-145
    • /
    • 2015
  • This study was aimed at analyzing NOx conversion characteristics in the HC-SCR with biodiesel content changes of the secondary fuel injection (BD0, BD10, BD25). Test conditions for temperature were set to $290^{\circ}C$, $320^{\circ}C$ and $350^{\circ}C$ considering the upstream temperature of a HC-SCR, distillation of the secondary injected fuels and etc. The amount of fuel injection was adjusted with a fixed space velocity of 55,000(1/h). According to the test results of distillation, the T90 was the same level about $350^{\circ}C$ on all test fuels and the amount of evaporation was reduced at lower than $350^{\circ}C$ temperature condition with increasing biodiesel content. As biodiesel content which is mixed with the secondary injected fuel is increased, NOx reduction efficiency was determined to decrease. The difference of the Nox reduction ratio in a high temperature condition($320^{\circ}C$ and $350^{\circ}C$) than the low temperature($290^{\circ}C$) was more significant. These results are thought to be poor evaporation properties (distillation) and high molecular weight of the biodiesel.