• Title/Summary/Keyword: evacuation space

Search Result 184, Processing Time 0.026 seconds

A Study on the Research Trends of Smoke Movement in Fire (화재 시 연기거동 관련 연구 동향에 관한 조사)

  • Kim, Hyung-Jin;Shin, Yi-Chul;Hwang, Eun-Kyung;Hwang, Keum-Suk;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.317-320
    • /
    • 2008
  • Smoke is recognized as the major killer in fire situation. smoke often migrate to building locations remote the fire space, threatening life and elevator shafts frequently become smoke-logged, there by blocking evacuation and inhibiting rescue and fire fighting. It is the aim of this study to investigate and analyze the research trends of smoke movement in Fire.

  • PDF

Evacuation Analysis for a Passenger Ship Using a Cellular Automata Model with Group Behavior (집단 행동을 나타내는 Cellular Automata 모델을 사용한 여객선 승객 탈출 분석)

  • Cha, Ju-Hwan;Ha, Sol;Lee, Kyu-Yeul
    • Journal of the Korea Society for Simulation
    • /
    • v.20 no.4
    • /
    • pp.149-155
    • /
    • 2011
  • This paper presents simulations of advance evacuation analysis using a cellular automata model for passenger behavior in an emergency of passenger ship. The proposed cellular automata model divides the space in a uniform grid called "cell." Each passenger is located in a cell and moves to another cell according to a set of local rules assumed to be associated with the individual and crowd behaviors of the passengers. To verify the usefulness of the proposed cellular automata model, 11 tests, all of which are specified in International Maritime Organization Maritime Safety Committee/ Circulation 1238 (IMO MSC/Circ. 1238), were implemented, and it was confirmed that all the requirements of these tests had been met.

Syntax-based Accessibility Analysis Algorithm for Indoor Spaces (실내공간을 위한 기반 Syntax 접근성 분석 알고리즘)

  • Kim, Hye-Yeong;Jeon, Cheol-Min
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2007.10a
    • /
    • pp.247-256
    • /
    • 2007
  • Accessibility is a field of study that has primarily been applied to urban or transportation problems two dimensionally. However, in large complex buildings as shopping centers or hospitals, inter-spatial accessibility among compartments has to be taken into account such as in building layouts or evacuation planning. This study expands space syntax theory, one of accessibility-related methodologies used for computing connectivity in urban or architectural spaces, into 3D indoor spaces. Although space syntax is basically a topology-based theory that does not consider general costs such as distance or time, this study suggests modification that incorporates different types of impedances in moving between places including distances, turns and transfers between floors. The proposed method is applied to a 3D campus building model in computing and displaying the accessibility to exit doors or cohesive accessibility among similar functions.

  • PDF

A Study on the Use of Balcony Areas to Improve Fire Escape for Residents in Apartments (화재피난 방안 수립을 위한 공동주택 거주자의 발코니 사용실태 조사)

  • Lee, So-Young;Lee, Myung-Sik
    • Korean Journal of Human Ecology
    • /
    • v.17 no.3
    • /
    • pp.541-552
    • /
    • 2008
  • With the increase of apartments and expansion of balcony areas, fire safety issues are becoming more important. Many researchers have conducted a lot of researches to reduce vertical flame spread in the balcony when an apartment unit is in fire. However, there have rarely been studies to use balcony area as a space for fire escape and evacuation. The study aims to examine the conditions of balcony use in apartments in order to find out prevention elements from fire escape and evacuation, and to investigate residents' satisfaction with balcony. For this study, questionnaires were collected from apartment residents and workers of architectural planning and construction companies. The findings show as follows: first, the balcony is generally used as a storage in each apartment unit nowadays. Second, when fire breaks out, many storage items could disturb residents' safe escape by blocking escape route, and easily promote to spread flame vertically in the balcony.

A Case Study on M & E Design for Double-Deck Tunnel in Urban Area (도심지 대심도 복층터널의 환기 및 방재계획)

  • Byun, Sang-Hun;Jeong, Jae-Ho;Jun, Duk-Chan;Shin, Il-Jae;Sim, Dong-Hyun
    • Tunnel and Underground Space
    • /
    • v.21 no.4
    • /
    • pp.281-286
    • /
    • 2011
  • The west underground express way is a recent initiated BTO (Build-Transfer-Operate) project for releasing heavy traffic of the existing west express way which is notorious on-ground road for extremely traffic stuck area in the west of Seoul, South Korea. The new express way for light vehicles is the first double-deck tunnel ever designed in South Korea and 10.91 km long including both open cut structures and concrete lining with middle-deck in bored tunnel. Because the new express way is going through underground of heavily populated area, mechanical & electrical design for the safety of drivers in tunnel is one of the most important parts among many design issues. This paper discusses M & E design focuses including ventilation-evacuation plan and various safety facilities.

A Comparative Study on the Spatial Layout Characteristics of Modern Apartment Floor Plan and 'Standard Korea Traditional-Houses Floor Plan' (현대 아파트 평면도와 한옥표준평면도의 공간배치 특성 비교 연구)

  • Hwang, Yong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.271-278
    • /
    • 2019
  • This study compares the space depth and layout of a modern apartment floor plan (MAFP) and the standard floor plan of traditional Korean houses (STKHs), which has preserved the traditional beauty of Korea. Space Syntax was applied to compare the MAFP and STKH. The space within MAFP was more divided into many spaces than the STKH. In both types of floor plans, the living room space had the highest degree of integration and was used for central functions in the each floor plan. The STKH and the space in the MAFP have more segregated space than integrated space. In the STKH, the master bedroom and other rooms were found to be segregated space. However, the master bedroom of the MAFP was highly integrated space. The function of the thet maru has been greatly reduced in the STKH, and the numaru was classified as a highly segregated space. The evacuation space was the most segregated space in the MAFP. The STKH has been adapted and changed according to the trends of the times, and the MAFP reflects our traditional living habits.

A Study on the Librarian's Perception about the Utilization of Libraries as Evacuation Facilities (도서관을 대피시설로 활용하는 방안에 대한 사서 인식 조사 연구)

  • Noh, Younghee;Ro, Ji-Yoon
    • Journal of Korean Library and Information Science Society
    • /
    • v.51 no.2
    • /
    • pp.55-77
    • /
    • 2020
  • In the third comprehensive library development plan, the formal and informal social safety space function of the library is used as a project. Therefore, this study investigated whether libraries were designated as evacuation facilities and related service status, and librarians' awareness, perception and attitude toward disaster and disaster response services. Based on this, it was intended to propose a direction to activate disaster and disaster response services. The research results are as follows. First, it is necessary to improve the perception of librarians who are the service providers. Second, discussions on spatial aspects, such as temporary or permanent, are needed. Third, development of disaster and disaster-related service models is required. Fourth, the administration's support and management are essential for the effectiveness of the library's function as a social safety space. Fifth, when developing guidelines for the role of libraries as social shelters and related services, specific details to address the concerns of individual libraries and librarians need to be specified.

3D Affordance Field based Crowd Agent Behavior Simulation (3D 행동 유도장 기반 대규모 에이전트 행동 시뮬레이션)

  • Ok, Sooyol;Han, MyungWoo;Lee, Suk-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.5
    • /
    • pp.629-641
    • /
    • 2021
  • Crowd behavior simulations have been studied to further accelerated and refined by parallelism by inducing agent-interacting forces into the image field representing the forces of attraction and repulsion. However, it was difficult to consider rapidly changing environments such as fire situations in buildings because texture images must be generated in advance simulation starts and simulations can only be performed in 2D spaces. In this paper, we propose a crowd agent behavior simulation method based on agent's 3D affordance field for flexible agent behavior in variable geomorphological environments in 3D space. The proposed method generates 3D affordance field related to agents and sensors in 3D space and defines the agent behavior in 3D space for the crowd behavior simulation based on an image-inducing field to a 3D space. Experimental results verified that our method enables the development of large-scale crowd behavior simulations that are flexible to various fire evacuation situations in 3D virtual spaces.

A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD (PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.527-539
    • /
    • 2018
  • The subway used by many passengers is required to maintain a safe and comfortable environment and PSD (Platform Screen Door) must be installed in the platform after reinforcing the standard in 2003. In the previous research, in case of subway fire to control it, it is necessary to design the optimal ventilation and smoke exhaust system according to equipment capacity of the smoke exhaust system. Therefore, in this study, based on the results of previous research, three-dimensional numerical analysis was performed for the CO gas and smoke flow by the subway ventilation system in case of platform fire. As a result of this study, it was found that in case of emergency, if only the upper-level smoke exhaust system is activated, the risk of evacuation is high due to CO gas (653.8 ppm) and smoke concentration ($768.4mg/m^3$). And when all the smoke exhaust systems are activated and only the fire side PSD is opened, CO gas (36.0 ppm) and smoke concentration ($26.2mg/m^3$) are detected and the propagation range of smoke flow was reduced. When all the smoke exhaust systems are activated and only the fire side PSD is closed, it was analyzed as the most effective ventilation mode in the evacuation environment due to the absence of smoke-recirculation.

A numerical study on the performance of the smoke exhaust system according to the smoke exhaust method in emergency station for railway tunnel (철도터널 구난역의 제연방식에 따른 제연성능에 관한 수치 해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Seo, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.845-856
    • /
    • 2017
  • In the long railway tunnel, in order to secure safety in case of fire, it is required a emergency station. However, there is no standard or research results on smoke exhaust method and exhaust flow rate in emergency station, so it is necessary to study the smoke exhaust system for emergency station. In this study, we are created a numerical analysis model for emergency station where the evacuation cross passage connected to the service tunnel or the relative tunnel was installed at regular intervals (40 m intervals). And the fire analysis are carried out by varying the fire intensity (15, 30MW), the smoke exhaust method (only air supply, forced air supply and exhaust, forced air exhaust only), and the air flow rate (7, 14, $40m^3/s$). From the results of fire analysis, temperature and CO concentration are analyzed and ASET based on the limit temperature are compared at various condition. As a result, in the case with fire intensity of 15 MW, it is shown that a sufficiently safe evacuation environment can be ensured by applying forced air supply and exhaust method or forced air exhaust only method when the air flow rate is $7m^3/s$ above. In case of fire intensity of 30 MW, it is impossible to maintain the safety evacuation environment for more than 900 seconds when the exhaust air volume is below $14m^3/s$. And when the air flow rate is $40m^3/s$, the exhaust port is disposed at the side portion of the upper duct, which is most advantageous for securing the temperature-based safety.