• Title/Summary/Keyword: evacuation space

Search Result 184, Processing Time 0.025 seconds

Implementation of EO/IR Camera for Fire-fighting of Narrow Space (협소거주공간 진화를 위한 EO/IR카메라 구현)

  • Park, Hyun-Ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.628-629
    • /
    • 2018
  • Recently, residential spaces in urban areas have changed into multi - family residential spaces. There is a feature that smoke is charged when a fire occurs here. Also, the evacuation route and the direction of the outflow of smoke are the same, and the possibility of inhaling the smoke of the evacuees is very high. When fighting fire in a narrow residential space such as a dwelling in a downtown area, exploration is the most important. For this purpose, we implement EO / IR sensor which can be mounted on firefighter 's helmet and can be used for fire detection. By using the EO / IR operation test, we can derive the results that can be used for research and development of the fire search sensor.

  • PDF

Evaluation of Civil Defense Evacuation Shelter Locations in Fitness according to the Walking Speed and Changing Floating Population in Time and Space (시공간 유동인구 변화와 보행속도에 따른 민방위 비상 대피시설 위치의 적절성 평가)

  • Park, Jae-Kook
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.95-103
    • /
    • 2018
  • This study set out to evaluate the fitness of shelter locations by taking into consideration service zones according to walking speed, the changing population between day and night, and walking routes. Walking speed was defined as 1.6 m/s, 2 m/s based on the cases of previous studies. The changing population between day and night was estimated with the dasymetric mapping technique. Shelter service zones according to walking speed and routes were analyzed with the network of the location allocation model. The findings show some shelters had limits with their capacity according to the changing floating population and walking speed in time and space and raise a need to appoint additional shelters.

Categorizing Safety Management Elements for Fire Preparation and Assessemnt of Fire Hazard (화재에 대비한 지하공간의 안전관리 요소분류 및 화재위험성 평가방안)

  • Bae, Yoonshin;Park, Jihye
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.96-109
    • /
    • 2011
  • In this study, risk categorized five safety management elements(equipment and structure, evacuation, lifesaving and fire extinguishing, performance based fire safety plan, operations management) were classified in order to establish safety system of underground space. Using classified safety management elements, assessment of fire hazard was performed. After calculating the grade of evaluation categories, assessment of fire hazard was suggested. The three grades of evaluation categories are classified as to importance and four criteria of evaluation are classified as to check result based on subdivisions.

A basic study on improvement of Disasters Prevention System using space information from 3D CAD - focused on Multiple-use Facilities - (3D CAD 공간 정보를 활용한 방재 시스템 개선에 관한 기초 연구 - 다중이용시설물 중심으로 -)

  • Lee, Myoung-Hoon;Ahn, Byung-Ju;Kim, Jae-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.189-193
    • /
    • 2009
  • As large-scale buildings, skyscrapers, and multi-purpose buildings recently increase in numbers dramatically the internal space of such buildings becomes more and more large and complicated accordingly. The Multi-purpose buildings are increasing rapidly in number, and concerns over the evacuation process in case of fire emergency are also increasing. However, A controller who is responsible for visitor's safety makes a decision about measures for visitor safety in human based decision making process. Many potential accidents that are caused by human error lurk in results of the process. The accidents can be decreased by changing the decision making process from human-based into technology-based. Through this study, the way to improve current disasters prevention system is presented and it can also improve shelter inducement methods effectively. SICS(Spatial Information Control System) which is being studied in other research is used as the tool for improvement.

  • PDF

Network Model for Managing Interior Space in Real-Time (실시간 실내 공간관리를 위한 네트워크 모델)

  • Oh, Jung-Woo;Kim, Kyung-Hwan;Lee, Yoon-Sun;Kim, Byeong-Su;Kim, Whoi-Yul;Kim, Jae-Jun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.840-843
    • /
    • 2007
  • There is a tremendous need for an effective indoor facility management since the building are tend to be built taller and bigger due to latest technology, Also, information that is continuously used and transferred during the design and construction phase is emerging due to 3D object-oriented CAD. Therefore, a system that will use such information for facility management should be developed. In this study, we present the methodology for definition the process that generates the Space Network Model automatically and examine the effective value of it.

  • PDF

Dural Reconstruction in Refractory Cranial Infection using Omental Free Flap (반복적인 두개내 감염에서 유리 대망피판을 이용한 경질막 재건)

  • Yoo, Ji Han;Eun, Seok Chan;Han, Jung Ho;Baek, Rong Min
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.670-673
    • /
    • 2009
  • Purpose: Epidural abscesses and subdural empyemas after craniotomy are uncommon, potentially lethal, complications of neurosurgery. Patients with these complications may be difficult to manage and dural reconstruction in these patients are challenging. Methods: A 28 - year - old female patient showed recurrent intracranial infection after craniotomy for evacuation of a arachnoid cyst and subdural hematoma. Despite prolonged systemic antibiotic administration and a debridement of the subdural space, infection persisted, as evidenced by persistent fever, an elevated WBC count, CSF leakage, low CSF glucose level, and purulent wound discharge. The authors removed the previously applied lyophilized dura and transferred free omental flap to reconstruct the dura, obliterate the cyst and cover the cerebral hemisphere in the craniotomy defect. Microvascular anastomosis was between gastroepiploic and superficial temporal vessels. Results: The postoperative course was uneventful and flap survival was excellent. The infection - resistant omental tissue allowed sufficient blood circulation and dead space control. The patient was discharged 1 month after surgery and wound discharge or recurrence was absent during 13 months of follow up periods. Conclusion: The use of vascularized free omentum proved useful in cases of intractable cranial wound infection and cerebrospinal fluid leakages.

A Optimization of Fire Safety Design in Multiplex Cinema Theater (국내 복합상영관 시설의 방재대책에 관한 연구)

  • 허준호;윤명오
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.43-50
    • /
    • 2002
  • 21C, Multiplex Cinema Theater is made from movie industry developed and become a place where we can spend our free time and consuming. But, theater users, who are many and unspecified persons, are short of information on the Multiplex Cinema Theater, so that they may be injured or killed at the occurrence of fire accident. Particularly, Multiplex Cinema Theater is a place that underground space or top floor in highrise building had many people in theaters. However, this problem is difficult to solve that to protect human being and properties at the occurrence of fire accident in the Multiplex Cinema Theater, In order to overcome such problems, Multiplex Cinema Theater need fire protection solutions facilities concerning particulars to pay attention to the safety on a fire and evacuation. This study analysed Multiplex Cinema Theater concept and computer simulation for risk point.

An Experiment on Walking Speeds of Freshmen Unexperienced in Shipboard Life on a Passenger Ship (승선생활 미숙련 대학 신입생들의 여객선 내 보행속도 실험)

  • Hwang, Kwang-II
    • Journal of Navigation and Port Research
    • /
    • v.37 no.3
    • /
    • pp.239-244
    • /
    • 2013
  • To increase the safety of onboard evacuation of guests who is unfamiliar with onboard living conditions, this study measured and compared the onboard walking speeds of 81 participants on a passenger ship, I t were found that the walking speeds at corridor on navigation were slower than those at berth by 27.2%, and the speeds of walking on the corner on navigation were slower than those at berth by 23.2%. This means that the ship motion on navigation directly influenced walking speeds. The walking speeds of upward-stairs and downward-stairs were measured to be 0.71m/s and 0.75m/s, respectively. From the crowd counter-flow experiments, because of the narrow space between participants, the walking speeds were decreased as person after person. And it was clear that the group's walking speeds were determined by the walking speeds of leading person(s) of the group. The walking speeds obtained this study were different from those of IMO guideline(MSC/Circ 1033).

The process of Indoor Space Combination Network Model based on object oriented CAD data and its application (CAD 객체 정보에 기초한 공간 정보 네트워크 모델의 구성 프로세스와 활용방안)

  • Oh, Jung-Woo;Kim, Kyung-Hwan;Lee, Yoon-Sun;Ahn, Byung-Ju;Kim, Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.6
    • /
    • pp.129-136
    • /
    • 2008
  • There is a tremendous need for an effective indoor facility management since the building are tend to be built taller and bigger due to latest technology. Also, information that is continuously used and transferred during the design and construction phase is emerging due to 3D object-oriented CAD. Therefore, a system that will use such information for facility management should be developed. In this study, we have defined a process that will automatically create an spatial network model and also verified the usability by establishing an sample model. As a result, an effective spatial network has been generated and an evacuation path finder was found efficiently.

Derivations of Positive Pressure Condition for Development of Foldable Safe Pathway in Railway Tunnel Fires (철도터널화재용 접이식 대피통로 개발을 위한 양압 조건 도출)

  • Kim, JiTae;Ro, Kyoungchul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.284-289
    • /
    • 2019
  • The Korea Foldable safe pathway system is an evacuation support system to get temporary evacuation route in railway tunnel and large space fires. A prevention smoke screen is unfolded in fires and it is needed to prevent heat and smoke from fire source. Therefore, ventilation system for positive pressure condition is equipped with foldable safe pathway system. Numerical analyses of temperature and pressure distribution with distance from fire source were performed considering fire scenario of new train vehicle. The smoke temperatures did not exceed $200^{\circ}C$ that distance from the fire source was more than 20 m and smoke pressure was reduced with distance from fire source. Maximum smoke pressure was 14 Pa and average pressure was 6 Pa in position of prevention smoke screen. As results, to install foldable safe pathway system, ventilation system is need to maintain 6 Pa positive pressure condition.