• 제목/요약/키워드: estimation of the unit load

검색결과 105건 처리시간 0.025초

비점오염 발생 원단위 산정방법에 대한 고찰 - 논 비점오염 원단위를 중심으로 - (A Study on the Estimation Methods of Nonpoint Pollutant Unit Load - Focus on Nonpoint Pollutant Unit Load in Paddy Field -)

  • 최동호;최순군;김민경;허승오;홍성창;엽소진;윤광식
    • 한국농공학회논문집
    • /
    • 제61권3호
    • /
    • pp.15-22
    • /
    • 2019
  • In order to preserve water environment, Total Maximum Daily Load(TMDL) is used to manage the total amount of pollutant from various sources, and the annual average load of source is calculated by the unit load method. Determination of the unit load requires reliable data accumulation and analysis based on a reasonable estimation method. In this study, we propose a revised unit load estimation method by analyzing the unit load calculation procedure of National Institute of Environment Research(NIER) method. Both methods were tested using observed runoff ratio and water quality data of rice paddy fields. The estimated values with the respective NIER and revised NIER methods were highly correlated each other. However, the Event Mean Concentration(EMC) and the runoff ratio considered in the NIER method appeared to be influenced by rainfall classes, and the difference in unit load increases as the runoff and EMC increase. The error can be further increased when the EMC and runoff ratio are changed according to changes in rainfall patterns by climate change and change of agricultural activities. Therefore, it is recommended to calculate unit load by applying the revised NIER method reflecting the non point pollution runoff characteristics for different rainfall classes.

논으로부터 배출되는 영양물질 오염부하량 원단위 산정 방법 개선 방안 검토 (Improvement Measures of Pollutants Unit-Loads Estimation for Paddy Fields)

  • 정재운;윤광식;최우정;최우영;주석훈;임상선;곽진협;이수형;김동호;장남익
    • 한국물환경학회지
    • /
    • 제24권3호
    • /
    • pp.291-296
    • /
    • 2008
  • Pollutant unit load developed by Ministry of Environment (MOE) in 1995 has been a tool commonly used for water quality management and environmental policy decision. In spite of the convenience of the method in application, the shortcoming of the method has been criticized especially for nonpoint source pollution from paddy field. In this paper the estimation procedures of pollutant unit load from paddy field in the major river basins (Han, Nakdong, Geum, and Youngsan river) were investigated, and some suggestions of improvement measures of the unit-load estimation were made. The investigation showed that the distributions of rainfall, run-off, and run-off ratio, which are the most important factors affecting discharge amount of pollutants, were not similar among river basins. Such differences seemed to result in a greater unit loads estimation at Han river and at Nakdong river watersheds compared to the others. Therefore, it is not likely to be rationale to compare unit load among the watersheds without consideration of such differences. We conclude that estimation of unit-load through an intensive monitoring of pollutant discharge is crucial for better estimation of unit-load. When such an intensive monitoring is not easy due to labor and expense restriction, we suggest that unit-load should be estimated based on the storm-events which is a representative rainfall-runoff event of the area.

유닛모듈 운반하중에 관한 확률분포 모델 추정 (Estimation of the Probability Distribution Model on the Load of Transport of the Unit Module)

  • 박남천;김균태;김석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.220-221
    • /
    • 2014
  • Recently It has been required the research for the load of transport of the unit module to secure the safety of the transport locking device. So the purpose of this study is to analyze the probability distribution of the load of transport of unit modular when transporting unit modular by vehicle.

  • PDF

자동창고시스템의 성능평가를 위한 M/G/1 대기모형 (M/G/1 Queueing Model for the Performance Estimation of AS/RS)

  • 이문환;임시영;허선;이영해
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2000년도 춘계공동학술대회 논문집
    • /
    • pp.253-256
    • /
    • 2000
  • In general, Automated Storage/Retrieval Systems (AS/RS ) have racks of equal sized cells to utilize the concept of unit-load. Most of the techniques for the performance estimation of a unit-load AS/RS are a static model or computer simulation. Especially, their models were developed under assumption that the Storage/Retrieval (S/R) machine performs only single command (SC) or dual command (DC). In reality, defending on the operating policy and the status of the system at a particular time, the S/B machine performs a SC or a DC, or becomes .: idle. In order to resolve these weak points, we propose a stochastic model for the performance estimation of unit-load AS/RS by using a single-server queueing model. Expected numbers of waiting storage and retrieval commands are found

  • PDF

경안천 유역 지적공부에 나타난 특정지목의 토지이용 특성 세분화를 통한 비점오염 부하량 산정 개선방안 (Unit-load Method for the Estimation of Non-point Pollution Loads by Subcategorizing the Land-use Category Reflected in the National Land Register Data : A Case Study of Kyeongan Watershed in South korea)

  • 이범연;이창희;하도;이수웅
    • 한국물환경학회지
    • /
    • 제26권4호
    • /
    • pp.598-607
    • /
    • 2010
  • One of constraints in the application of unit-load method to estimate non-point pollution loads in the total water pollutant load management system (TWPLMS) is the limited numbers of applicable unit-loads. Since only 7 unit-loads are currently available for total 28 land-use categories in the national land register data, each unit-loads inevitably have to represent several land-use categories regardless of their actual land coverage characteristics. As a way to minimize the problem, this study suggested a nested application of the available unit-loads based on the analysis of high resolution aerial images taken in the Kyeongan watershed. Statistical analysis of three selected land-use categories such as school, apartment complex, and golf course showed that there exit significant (95% confidence level) relationships between the registered land-uses and actual land coverages. The school and apartment complex currently considered as 100% ground have only 65% and 80% of ground characteristics, respectively. Golf course, which is considered as 100% pasture, has about 5% of ground area. This indicates that the unit-load method using in TWPLMS can give over estimated non-point pollutant loads for the school and apartment complex (19.8~54.4%) but under estimation for the golf course (80.9%).

강우시와 비강우시 BOD 유출 특성 조사 및 원단위 평가 (Characteristics of Biochemical Oxygen Demand Export from Paddy Fields during Storm and Non-storm Period and Evaluation of Unit Load)

  • 최동호;조소현;황태희;김영석;정재운;최우정;박현규;윤광식
    • 한국물환경학회지
    • /
    • 제33권5호
    • /
    • pp.531-537
    • /
    • 2017
  • The biologic Oxygen Demand (BOD) is a reliable and generally accepted indicator of water pollution by organic pollutants. Accordingly, estimation of BOD export from paddies carries important implications fwith regard to water management in rural areas. In this study, hydrology and BOD concentration were monitored during the period 2008 through 2012, in an effort to understand the characteristics of BOD export from paddy fields. The findings demonstrated that BOD load by rainfall above 50 mm. occupied about 50 % of total load, whereas the load by less than ten mm. rainfall occupied about 29 % of the total load during periods of stormy activity. It therefore seems that it could be possible to reduce the BOD load up to 29 % during storm periods, when drainage control conducted for rainfall less than ten mm.(an amount which is relatively easy to manage). The documented mean loads of storm and non-storm were $17.1kg\;ha^{-1}\;yr^{-1}$ and $11.2kg\;ha^{-1}\;yr^{-1}$, respectively. The BOD load during the significant rainfall period was similar to the renewed unit load by NIER (2014). However, there were substantial differences between unit load and actual load when the non-storm load was incorporated into the BOD load estimation from paddy fields. In view of the foregoing, it is felt that, the non-storm load needs to be further considered and managed for the successful implementation of Total Maximum Daily Load (TMDL) program.

지역냉방 공동주택 적정 냉방부하 산정 (The Estimation of Cooling Load for District Cooling in Apartment Buildings)

  • 김상훈;변운섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.643-649
    • /
    • 2008
  • The purpose of this study is to establish a standard for unit cooling load in central control type apartment applied district cooling. The model of unit household was selected. And the standard of coefficient of overall heat transmission, location of unit household, indoor air temperature, solar radiation & thermal conduction at window and interior load was selected, and region, expansion or non-expansion of balcony, pyeong type, azimuth, rate of window area was applied as parameter. And then cooling load simulation was performed. Based on the result of simulation, the synthetic district cooling load was presented for selecting heat source of apartment applied district cooling, and unit cooling load was analyzed according to design parameter.

  • PDF

원단위법을 이용한 홍보유역의 오염부하량 산정 (Estimation of Pollutants Loads using Unit Load Method in Hong-Bo Watershed)

  • 김선주;이석호;허배영
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.492-496
    • /
    • 2001
  • The purpose of this study is to estimation of pollutants loads using unit load method in Hong-bo watershed. In general, because river water quality management have been conducted with point source pollutant in our country, pollutants caused by precipitation have not been managed well so far. Especially the pollutants tends to concentrate in the reservoir of reclaimed land. Therefore, the reservoir of reclaimed land is need to continuous monitoring and update of an accurate data. also, It is need to improvement of environmental pollution. There are divide into nine sub-catchments and made an estimate of pollutants loads using unit load method in Hong-bo basin. The sample of data was during the 10 years.

  • PDF

교량지역의 다양한 비점오염물질 원단위 산정방법 비교 (Comparison of Estimation Method of Pollutant Unit Loads from Bridge Area)

  • 김태원;길경익
    • 한국물환경학회지
    • /
    • 제27권5호
    • /
    • pp.597-604
    • /
    • 2011
  • This research analyzed the runoff patterns and estimated unit loads of selected pollutatnts using monitored data conducted for three years in a bridge area. Three estimating methods; the arithmetic average method, the regression method and the rainfall class method were used to estimate the unit load. Results of three estimating methods were compared with the unit pollutant loads from landuses in Korea and the unit pollutant loads from urban watersheds in Milwaukee, USA. Unit load using the arithmetic mean method were found to be overestimated. In terms of TSS, unit loads of two estimate were half lower than that of USA. Estimated TN and TP unit loads of three estimate were lower than that of Ministry of Environment in Korea.

LP 최적화에 의한 토지피복도 기반 토지계 발생부하 원단위 산정 (Land Generated Waste Load Unit Estimation Based on Land Use Map with LP Optimization)

  • 박경옥;이창희
    • 한국습지학회지
    • /
    • 제18권3호
    • /
    • pp.226-231
    • /
    • 2016
  • 토지이용에 따른 수질에 미치는 영향을 파악하기 위해서는 토지피복기반의 토지계 발생부하 원단위가 필요하다. 실측자료를 기반으로 토지피복기반 원단위를 도출하기에는 많은 인력과 시간을 필요로 한다. 이에 본 연구에서는 최적화를 통해 토지피복기반의 원단위 도출 방법을 제안하였다. 최적화란 주어진 조건 안에서 가장 좋은 최적해를 구하는 과정이며, 본 연구에서는 상용 프로그램인 Microsoft Excel에서 제공하고 있는 Excel Solver를 이용하여 최적화를 수행하였다. 공주시와 서천군의 2010년 위성영상 기반으로 작성된 2012년 환경부 중분류 토지피복도를 활용하여, BOD, T-N, T-P에 대한 토지피복기반 원단위를 도출하였다. 본 연구에서 수행한 토지피복기반 원단위 산정 연구는 국토 이용에 따른 오염원 발생변화를 보다 명확히 판별할 수 있을 것으로 판단된다.