• 제목/요약/키워드: equivalent linear system

검색결과 380건 처리시간 0.024초

An equivalent linear SDOF system for prediction of nonlinear displacement demands of non-ductile reinforced concrete buildings with shear walls

  • Saman Yaghmaei-Sabegh;Shabnam Neekmanesh;Nelson Lam;Anita Amirsardari;Nasser Taghizadieh
    • Structural Engineering and Mechanics
    • /
    • 제85권5호
    • /
    • pp.655-664
    • /
    • 2023
  • Reinforced concrete (RC) shear wall structures are one of the most widely used structural systems to resist seismic loading all around the world. Although there have been several efforts to provide conceptually simple procedures to reasonably assess the seismic demands of structures over recent decades, it seems that lesser effort has been put on a number of structural forms such as RC shear wall structures. Therefore, this study aims to represent a simple linear response spectrum-based method which can acceptably predict the nonlinear displacements of a non-ductile RC shear wall structure subjected to an individual ground motion record. An effective period and an equivalent damping ratio are introduced as the dynamic characteristics of an equivalent linear SDOF system relevant to the main structure. By applying the fundamental mode participation factor of the original MDOF structure to the linear spectral response of the equivalent SDOF system, an acceptable estimation of the nonlinear displacement response is obtained. Subsequently, the accuracy of the proposed method is evaluated by comparison with another approximate method which is based on linear response spectrum. Results show that the proposed method has better estimations for maximum nonlinear responses and is more utilizable and applicable than the other one.

마찰감쇠기-가새 시스템의 확률분포 기반 등가선형화에 관한 실험적 연구 (Experimental Study on the Probability-based Equivalent Linearization of a Friction Damper-Brace System)

  • 강경수;박지훈
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.394-403
    • /
    • 2006
  • A new equivalent linearization technique is proposed for a friction damper-brace system (FDBS) idealized as a elastoplastic system. The equivalent linearization technique utilizes secant stiffness and dissipated energy defined by the probability distribution of the extremal displacement of the FDBS. In addition, a conversion scheme is proposed so that an equivalent linear system is designed first and converted to the FDBS. For comparative study, an existing model update technique based on system identification is modified in a form appropriate to update single element. For the purpose of verification, shaking table tests of a small scale three-story shear building model, in which a rotational FDBS is installed, are conducted and equivalent linear systems are obtained using the proposed technique and the model update technique. Complex eigenvalue analysis is conducted for those equivalent linear systems, and the natural frequencies and modal damping ratios are compared with those obtained from system identification. Additionally, RMS and peak responses obtained from time history analysis of the equivalent linear systems are compared with measured ones.

등가하중법 관점에서 분석한 프리스트레싱 텐던의 직선이동 (Analysis of the Linear Transformation of Prestressing Tendon Using Equivalent toad Method)

  • 오병환;전세진
    • 콘크리트학회논문집
    • /
    • 제14권6호
    • /
    • pp.843-850
    • /
    • 2002
  • 프리스트레스트 콘크리트 부재의 해석이론에서 텐던의 직선이동(linear transformation)은 텐던 배치에 대한 해석을 간략화시켜주는 장점이 있어 빈번히 다루어지고 있다. 본 논문은 그동안 간과되기 쉬웠던 직선이동에 내재된 근사화 및 그 영향을 밝히는데 중점을 두고 있으며, 주로 등가하중법(equivalent load method)을 통하여 직선이동의 이론을 분석하였다. 텐던이 이동하더라도 똑같은 등가하중 시스템이 산출되는 것을 직선이동으로 볼 경우, 기존의 등가하중법 고유의 내재된 가정은 그러한 직선이동의 원리가 성립하도록 하고 있으며, 반면 근사화가 포함되지 않은 엄밀한 의미의 등가하중 시스템에서는 그러한 원리가 성립하고 있지 않다 또한, 자체평형의 성질로부터 유도된 등가하중법을 직선이동에 적용하는 방안을 모색하였으며, 기존의 결과와 약간 다른 등가하중 시스템을 산출하였다. 논의를 확장하여 격납구조물 벽체 원환텐던(circumferential tendon)의 편심배치 문제를 직선이동의 관점에서 분석하였다.

무기억 균일 신호원에 대한 수리 형태론적인 불림과 등가 시스템의 통계적 비교 (Statistical comparison of morphological dilation with its equivalent linear shift-invariant system:case of memoryless uniform soruces)

  • 김주명;최상신;최태영
    • 전자공학회논문지S
    • /
    • 제34S권2호
    • /
    • pp.79-93
    • /
    • 1997
  • This paper presents a linear shift-invariant system euqivalent to morphological dilation for a memoryless uniform source in the sense of the power spectral density function, and comares it with dialtion. This equivalent LSI system is found through spectral decomposition and, for dilation and with windwo size L, it is shown to be a finite impulse response filter composed of L-1 delays, L multipliers and three adders. Th ecoefficients of the equivalent systems are tabulated. The comparisons of dilation and its equivalent LSI system show that probability density functions of the output sequences of the two systems are quite different. In particular, the probability density functon from dilation of an independent and identically distributed uniform source over the unit interval (0, 1) shows heavy probability in around 1, while that from the equivalent LSI system shows probability concentration around themean vlaue and symmetricity about it. This difference is due to the fact that dilation is a non-linear process while the equivalent system is linear and shift-ivariant. In the case that dikation is fabored over LSI filters in subjective perforance tests, one of the factors can be traced to this difference in the probability distribution.

  • PDF

제진장치가 설치된 구조물의 등가감쇠비 (Closed Form Formulas for Equivalent Damping Ratios of a Linear Structure Equipped with Damping Devices)

  • Hwang, Jae-Seung;Lee, Sang-Hyun;Min, Kyung-Won
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.370-377
    • /
    • 2002
  • Hwang et al (2001) proposed a new method for an evaluation of equivalent damping ratios of a linear structure with linear or nonlinear damping devices. This procedure has a disadvantage that it requires time history analysis for the whole system including damping devices, which may be troublesome for practical application. To tackle this problem closed form formulas for equivalent damping ratios are proposed in this study. It is assumed that the responses of MDOF system can be reproduced by an equivalent SDOF system which vibrates in a fundamental mode. The numerical analyses of a ten-story building equipped with linear viscous damper or active mass damper or friction damper show the effectiveness of equivalent SDOF model and closed form formulas.

  • PDF

A STOCHASTIC EVALUATION METHOD OF ACOUSTIC SYSTEMS BASED ON EQUIVALENT ZERO-MEMORY TYPE NON-LINEAR SYSTEM

  • Minamihara, Hideo;Ohta, Mitsuo
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.830-835
    • /
    • 1994
  • In this paper, a new method of statistically evaluating an output response probability distribution of a memory type non-linear system is practically derived based on a zero-memory type non-linear equivalent system. That is, first, the objective system is approximately and functionally separated into two functional parts, i.e., a zero-memory type non-linear part and a memory type linear part according to the well-known Wiener's idea. A whole mathematical frame of the output probability distribution is evaluated in an approximate but generalized form, based on the equivalent zero-memory type non-linear part. The memory effects between the input and the output of the system are reflected in the statistical parameters and the expansion coefficients.

  • PDF

Seismic responses of base-isolated buildings: efficacy of equivalent linear modeling under near-fault earthquakes

  • Alhan, Cenk;Ozgur, Murat
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1439-1461
    • /
    • 2015
  • Design criteria, modeling rules, and analysis principles of seismic isolation systems have already found place in important building codes and standards such as the Uniform Building Code and ASCE/SEI 7-05. Although real behaviors of isolation systems composed of high damping or lead rubber bearings are nonlinear, equivalent linear models can be obtained using effective stiffness and damping which makes use of linear seismic analysis methods for seismic-isolated buildings possible. However, equivalent linear modeling and analysis may lead to errors in seismic response terms of multi-story buildings and thus need to be assessed comprehensively. This study investigates the accuracy of equivalent linear modeling via numerical experiments conducted on generic five-story three dimensional seismic-isolated buildings. A wide range of nonlinear isolation systems with different characteristics and their equivalent linear counterparts are subjected to historical earthquakes and isolation system displacements, top floor accelerations, story drifts, base shears, and torsional base moments are compared. Relations between the accuracy of the estimates of peak structural responses from equivalent linear models and typical characteristics of nonlinear isolation systems including effective period, rigid-body mode period, effective viscous damping ratio, and post-yield to pre-yield stiffness ratio are established. Influence of biaxial interaction and plan eccentricity are also examined.

부하변동을 고려한 선형유도전동기의 동특성 분석 (Analysis of the Dynamic charactristics of Linear Induction Motor considering the variation of loads)

  • 전삼석;박찬원;임병옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1162-1164
    • /
    • 2005
  • A Linear Induction Motor that generates the direct thrust directly, is widely used for the operation system of electrified railroad, elevation system, conveyer system, and so on. There are two analysis methode of linear induction motor characteristics. One is the electrical magnetic analyzing, the other is analyzing equivalent circuit. The electrical magnetic analyzing methode has available advantages to consider the physical condition. The equivalent circuit analyzing methode has the elementary methode in the system of vector control and over shoot situation. In this paper, It is used the dynamic characteristic analyzing methode that can calculate efficiently the end effect by using equivalent circuit methode in the operating linear induction motor system modeling and doing simulation of output characteristics of vector controller.

  • PDF

등가자기회로를 이용한 리니어모터의 추력밀도계산 (Calculation of Force Density in Linear Motor Using Equivalent Magnetic Circuit)

  • 홍정표;강도현;주수원;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.96-98
    • /
    • 2001
  • In this paper, the equivalent magnetic circuit and FEM are used to calculate force density of linear BLDC motor. The equivalent magnetic circuit is hard to exact compose for analysis model and it is just applied to linear system. To flexible design and reducing the calculated and analyzed time, magnetic circuit has to be used for designing the linear BLDC motor and deducing equation of force density. Force density as parameter of permanent magnet and coil-side width that are important to determined force density can be estimated using equation of force density. FEM is used to prove reliability of equation of force density and to consider the nonlinear system. Equivalent magnetic circuit and result of FEM are similar, but it is little different by friction loss at the experiment.

  • PDF

Seismic equivalent linear response of a structure by considering soil-structure interaction: Analytical and numerical analysis

  • Maroua Lagaguine;Badreddine Sbartai
    • Structural Engineering and Mechanics
    • /
    • 제87권2호
    • /
    • pp.173-189
    • /
    • 2023
  • For a given structural geometry, the stiffness and damping parameters of the soil and the dynamic response of the structure may change in the face of an equivalent linear soil behavior caused by a strong earthquake. Therefore, the influence of equivalent linear soil behavior on the impedance functions form and the seismic response of the soil-structure system has been investigated. Through the substructure method, the seismic response of the selected structure was obtained by an analytical formulation based on the dynamic equilibrium of the soil-structure system modeled by an analog model with three degrees of freedom. Also, the dynamic response of the soil-structure system for a nonlinear soil behavior and for the two types of impedance function forms was also analyzed by 2D finite element modeling using ABAQUS software. The numerical results were compared with those of the analytical solution. After the investigation, the effect of soil nonlinearity clearly showed the critical role of soil stiffness loss under strong shaking, which is more complex than the linear elastic soil behavior, where the energy dissipation depends on the seismic motion amplitude and its frequency, the impedance function types, the shear modulus reduction and the damping increase. Excellent agreement between finite element analysis and analytical results has been obtained due to the reasonable representation of the model.