• Title/Summary/Keyword: equivalent linear system

Search Result 380, Processing Time 0.027 seconds

An equivalent linear SDOF system for prediction of nonlinear displacement demands of non-ductile reinforced concrete buildings with shear walls

  • Saman Yaghmaei-Sabegh;Shabnam Neekmanesh;Nelson Lam;Anita Amirsardari;Nasser Taghizadieh
    • Structural Engineering and Mechanics
    • /
    • v.85 no.5
    • /
    • pp.655-664
    • /
    • 2023
  • Reinforced concrete (RC) shear wall structures are one of the most widely used structural systems to resist seismic loading all around the world. Although there have been several efforts to provide conceptually simple procedures to reasonably assess the seismic demands of structures over recent decades, it seems that lesser effort has been put on a number of structural forms such as RC shear wall structures. Therefore, this study aims to represent a simple linear response spectrum-based method which can acceptably predict the nonlinear displacements of a non-ductile RC shear wall structure subjected to an individual ground motion record. An effective period and an equivalent damping ratio are introduced as the dynamic characteristics of an equivalent linear SDOF system relevant to the main structure. By applying the fundamental mode participation factor of the original MDOF structure to the linear spectral response of the equivalent SDOF system, an acceptable estimation of the nonlinear displacement response is obtained. Subsequently, the accuracy of the proposed method is evaluated by comparison with another approximate method which is based on linear response spectrum. Results show that the proposed method has better estimations for maximum nonlinear responses and is more utilizable and applicable than the other one.

Experimental Study on the Probability-based Equivalent Linearization of a Friction Damper-Brace System (마찰감쇠기-가새 시스템의 확률분포 기반 등가선형화에 관한 실험적 연구)

  • Kang, Kyung-Soo;Park, Ji-Hun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.4 s.109
    • /
    • pp.394-403
    • /
    • 2006
  • A new equivalent linearization technique is proposed for a friction damper-brace system (FDBS) idealized as a elastoplastic system. The equivalent linearization technique utilizes secant stiffness and dissipated energy defined by the probability distribution of the extremal displacement of the FDBS. In addition, a conversion scheme is proposed so that an equivalent linear system is designed first and converted to the FDBS. For comparative study, an existing model update technique based on system identification is modified in a form appropriate to update single element. For the purpose of verification, shaking table tests of a small scale three-story shear building model, in which a rotational FDBS is installed, are conducted and equivalent linear systems are obtained using the proposed technique and the model update technique. Complex eigenvalue analysis is conducted for those equivalent linear systems, and the natural frequencies and modal damping ratios are compared with those obtained from system identification. Additionally, RMS and peak responses obtained from time history analysis of the equivalent linear systems are compared with measured ones.

Analysis of the Linear Transformation of Prestressing Tendon Using Equivalent toad Method (등가하중법 관점에서 분석한 프리스트레싱 텐던의 직선이동)

  • 오병환;전세진
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.843-850
    • /
    • 2002
  • Linear transformation theory has been effectively used in the design and analysis of prestressed concrete structures. The underlying assumptions of the theory, which were often overlooked, are investigated in the respect of equivalent load method. As a result, it is found that the same equivalent loading system is produced for all the cases of the linear transformation by the assumptions of the conventional equivalent load method. On the other hand, equivalent loading systems in a strict and accurate sense do not satisfy the classical theories of the linear transformation. Also, it is shown that a little different equivalent loading system from the conventional one is obtained for each linear transformation according to the proposed equivalent load method that is derived from the self-equilibrium property of the tendon-induced forces. Therefore, it can be concluded that the linear transformation theory is valid only when referring to the conventional approximate equivalent load method. The discussions are further extended to the eccentrically located circumferential tendon in the wall of containment structures, where the problem of eccentricity is analyzed also from the view point of the linear transformation.

Statistical comparison of morphological dilation with its equivalent linear shift-invariant system:case of memoryless uniform soruces (무기억 균일 신호원에 대한 수리 형태론적인 불림과 등가 시스템의 통계적 비교)

  • 김주명;최상신;최태영
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.2
    • /
    • pp.79-93
    • /
    • 1997
  • This paper presents a linear shift-invariant system euqivalent to morphological dilation for a memoryless uniform source in the sense of the power spectral density function, and comares it with dialtion. This equivalent LSI system is found through spectral decomposition and, for dilation and with windwo size L, it is shown to be a finite impulse response filter composed of L-1 delays, L multipliers and three adders. Th ecoefficients of the equivalent systems are tabulated. The comparisons of dilation and its equivalent LSI system show that probability density functions of the output sequences of the two systems are quite different. In particular, the probability density functon from dilation of an independent and identically distributed uniform source over the unit interval (0, 1) shows heavy probability in around 1, while that from the equivalent LSI system shows probability concentration around themean vlaue and symmetricity about it. This difference is due to the fact that dilation is a non-linear process while the equivalent system is linear and shift-ivariant. In the case that dikation is fabored over LSI filters in subjective perforance tests, one of the factors can be traced to this difference in the probability distribution.

  • PDF

Closed Form Formulas for Equivalent Damping Ratios of a Linear Structure Equipped with Damping Devices (제진장치가 설치된 구조물의 등가감쇠비)

  • Hwang, Jae-Seung;Lee, Sang-Hyun;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.370-377
    • /
    • 2002
  • Hwang et al (2001) proposed a new method for an evaluation of equivalent damping ratios of a linear structure with linear or nonlinear damping devices. This procedure has a disadvantage that it requires time history analysis for the whole system including damping devices, which may be troublesome for practical application. To tackle this problem closed form formulas for equivalent damping ratios are proposed in this study. It is assumed that the responses of MDOF system can be reproduced by an equivalent SDOF system which vibrates in a fundamental mode. The numerical analyses of a ten-story building equipped with linear viscous damper or active mass damper or friction damper show the effectiveness of equivalent SDOF model and closed form formulas.

  • PDF

A STOCHASTIC EVALUATION METHOD OF ACOUSTIC SYSTEMS BASED ON EQUIVALENT ZERO-MEMORY TYPE NON-LINEAR SYSTEM

  • Minamihara, Hideo;Ohta, Mitsuo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.830-835
    • /
    • 1994
  • In this paper, a new method of statistically evaluating an output response probability distribution of a memory type non-linear system is practically derived based on a zero-memory type non-linear equivalent system. That is, first, the objective system is approximately and functionally separated into two functional parts, i.e., a zero-memory type non-linear part and a memory type linear part according to the well-known Wiener's idea. A whole mathematical frame of the output probability distribution is evaluated in an approximate but generalized form, based on the equivalent zero-memory type non-linear part. The memory effects between the input and the output of the system are reflected in the statistical parameters and the expansion coefficients.

  • PDF

Seismic responses of base-isolated buildings: efficacy of equivalent linear modeling under near-fault earthquakes

  • Alhan, Cenk;Ozgur, Murat
    • Smart Structures and Systems
    • /
    • v.15 no.6
    • /
    • pp.1439-1461
    • /
    • 2015
  • Design criteria, modeling rules, and analysis principles of seismic isolation systems have already found place in important building codes and standards such as the Uniform Building Code and ASCE/SEI 7-05. Although real behaviors of isolation systems composed of high damping or lead rubber bearings are nonlinear, equivalent linear models can be obtained using effective stiffness and damping which makes use of linear seismic analysis methods for seismic-isolated buildings possible. However, equivalent linear modeling and analysis may lead to errors in seismic response terms of multi-story buildings and thus need to be assessed comprehensively. This study investigates the accuracy of equivalent linear modeling via numerical experiments conducted on generic five-story three dimensional seismic-isolated buildings. A wide range of nonlinear isolation systems with different characteristics and their equivalent linear counterparts are subjected to historical earthquakes and isolation system displacements, top floor accelerations, story drifts, base shears, and torsional base moments are compared. Relations between the accuracy of the estimates of peak structural responses from equivalent linear models and typical characteristics of nonlinear isolation systems including effective period, rigid-body mode period, effective viscous damping ratio, and post-yield to pre-yield stiffness ratio are established. Influence of biaxial interaction and plan eccentricity are also examined.

Analysis of the Dynamic charactristics of Linear Induction Motor considering the variation of loads (부하변동을 고려한 선형유도전동기의 동특성 분석)

  • Chun, Sam-Suk;Park, Chan-Won;Lim, Byung-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1162-1164
    • /
    • 2005
  • A Linear Induction Motor that generates the direct thrust directly, is widely used for the operation system of electrified railroad, elevation system, conveyer system, and so on. There are two analysis methode of linear induction motor characteristics. One is the electrical magnetic analyzing, the other is analyzing equivalent circuit. The electrical magnetic analyzing methode has available advantages to consider the physical condition. The equivalent circuit analyzing methode has the elementary methode in the system of vector control and over shoot situation. In this paper, It is used the dynamic characteristic analyzing methode that can calculate efficiently the end effect by using equivalent circuit methode in the operating linear induction motor system modeling and doing simulation of output characteristics of vector controller.

  • PDF

Calculation of Force Density in Linear Motor Using Equivalent Magnetic Circuit (등가자기회로를 이용한 리니어모터의 추력밀도계산)

  • Hong, Jung-Pyo;Kang, Do-Hyun;Joo, Soo-Won;Hahn, Sung-Chin
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.96-98
    • /
    • 2001
  • In this paper, the equivalent magnetic circuit and FEM are used to calculate force density of linear BLDC motor. The equivalent magnetic circuit is hard to exact compose for analysis model and it is just applied to linear system. To flexible design and reducing the calculated and analyzed time, magnetic circuit has to be used for designing the linear BLDC motor and deducing equation of force density. Force density as parameter of permanent magnet and coil-side width that are important to determined force density can be estimated using equation of force density. FEM is used to prove reliability of equation of force density and to consider the nonlinear system. Equivalent magnetic circuit and result of FEM are similar, but it is little different by friction loss at the experiment.

  • PDF

Seismic equivalent linear response of a structure by considering soil-structure interaction: Analytical and numerical analysis

  • Maroua Lagaguine;Badreddine Sbartai
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.173-189
    • /
    • 2023
  • For a given structural geometry, the stiffness and damping parameters of the soil and the dynamic response of the structure may change in the face of an equivalent linear soil behavior caused by a strong earthquake. Therefore, the influence of equivalent linear soil behavior on the impedance functions form and the seismic response of the soil-structure system has been investigated. Through the substructure method, the seismic response of the selected structure was obtained by an analytical formulation based on the dynamic equilibrium of the soil-structure system modeled by an analog model with three degrees of freedom. Also, the dynamic response of the soil-structure system for a nonlinear soil behavior and for the two types of impedance function forms was also analyzed by 2D finite element modeling using ABAQUS software. The numerical results were compared with those of the analytical solution. After the investigation, the effect of soil nonlinearity clearly showed the critical role of soil stiffness loss under strong shaking, which is more complex than the linear elastic soil behavior, where the energy dissipation depends on the seismic motion amplitude and its frequency, the impedance function types, the shear modulus reduction and the damping increase. Excellent agreement between finite element analysis and analytical results has been obtained due to the reasonable representation of the model.