• Title/Summary/Keyword: equivalent

Search Result 12,578, Processing Time 0.045 seconds

Determination of equivalent elastic modulus of shotcrete-tetragonal lattice girder composite (사변형 격자지보재-숏크리트 합성부재의 등가물성 결정 기법)

  • Kang, Kyung-Nam;Song, Ki-Il;Kim, Sun Gil;Kim, Kyoung Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.2
    • /
    • pp.145-154
    • /
    • 2020
  • Steel set is a structure that stabilize the NATM tunnel until the installation of shotcrete, and it is combined after the shotcrete is installed to improve stability. In this study, determination approach for the equivalent elastic modulus of shotcrete-lattice girder composite is newly suggested for tunneling simulation. Also, a method was presented to calibrate the equivalent elastic modulus through the comparison of the full 3D model and equivalent model. When the conventional equivalent elastic modulus is used for shotcrete-lattice girder composite, the flexural strength of equivalent model is 130% smaller than that of full 3D model. Equivalent elastic modulus is adjusted considering the error of flexural strength. It is found that the error of flexural strength obtained from adjusted equivalent model using adjusted equivalent elastic modulus is reduced less than 1%.

Algorithm for Predicting Functionally Equivalent Proteins from BLAST and HMMER Searches

  • Yu, Dong Su;Lee, Dae-Hee;Kim, Seong Keun;Lee, Choong Hoon;Song, Ju Yeon;Kong, Eun Bae;Kim, Jihyun F.
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.8
    • /
    • pp.1054-1058
    • /
    • 2012
  • In order to predict biologically significant attributes such as function from protein sequences, searching against large databases for homologous proteins is a common practice. In particular, BLAST and HMMER are widely used in a variety of biological fields. However, sequence-homologous proteins determined by BLAST and proteins having the same domains predicted by HMMER are not always functionally equivalent, even though their sequences are aligning with high similarity. Thus, accurate assignment of functionally equivalent proteins from aligned sequences remains a challenge in bioinformatics. We have developed the FEP-BH algorithm to predict functionally equivalent proteins from protein-protein pairs identified by BLAST and from protein-domain pairs predicted by HMMER. When examined against domain classes of the Pfam-A seed database, FEP-BH showed 71.53% accuracy, whereas BLAST and HMMER were 57.72% and 36.62%, respectively. We expect that the FEP-BH algorithm will be effective in predicting functionally equivalent proteins from BLAST and HMMER outputs and will also suit biologists who want to search out functionally equivalent proteins from among sequence-homologous proteins.

Examination of validation for equivalent gas to replace natural gas (천연가스를 모사하는 등가가스의 유효성 검토)

  • Kim, Jong-Min;Lee, Seungro;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.128-135
    • /
    • 2013
  • In order to estimate the combustion characteristics and the gas interchangeability for natural gas with various compositions per each production area, equivalent gas are using to replace natural gas. It is known that an equivalent gas has the same the heating value, the compression factor, the relative density, CO emission and the burning velocity as the original natural gas. However, it is not reported that the flame shape and thermal efficiency and NOx emission by real gas appliance. In this study, equivalent gas was examined the validation to replace natural gas. The CO emission the burning velocity and the flame temperature were reconfirmed, and the flame shape, the NOx emission and the thermal efficiency were numerically and experimentally investigated. As results, there was not a large difference between natural gas and equivalent gas. This result demonstrated that there was no problem using equivalent gas to replace natural gas.

Beat Period Tuning Method Using an Equivalent Bell Model (등가 종 모델을 이용한 맥놀이 주기 조절법)

  • Kim, Seock-Hyun;Lee, Joong-Hyeok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.561-568
    • /
    • 2012
  • This study proposes a method of an equivalent bell model in order to tune the beat period of a Korean bell. In a Korean bell having a slight asymmetry, each circumferential mode splits into a mode pair which has a slight difference in frequency, and the interaction of the mode pair makes a beat in vibration and sound. An equivalent bell model which consists of an axi-symmetric bell and an equivalent point mass, has the same mode property as in a real bell. The equivalent bell model is constructed by the finite element analysis based upon the theory of a revolutionary shell. Using the equivalent bell model, the beat period is predicted when the bell thickness is locally decreased to improve the beat property. The predicted result is verified by experiment on a test bell. The proposed method is useful to save the time required for tuning the beat period of a large bell.

Design of Coupled-line Band-pass Filter Using New Equivalent Circuit of Tapped-line (탭 선로의 새로운 등가 회로를 이용한 결합 선로 대역 통과 필터 설계)

  • Lee, Il-Woo;Han, Seung-Hyun;Yun, Tae-Soon;Kwoun, Sung-Su;Hong, Tae-Ui;Lee, Jong-Chul
    • 한국ITS학회:학술대회논문집
    • /
    • v.2006 no.10
    • /
    • pp.187-190
    • /
    • 2006
  • In this paper, the equivalent circuit of tapped-line that is applied in the feeding of the band-pass filter with high coupling is suggested and the value of an equivalent circuit is mathematically defined. An equivalent circuit of tapped-line is composed by open stub and additional transmission line, and the electrical lengths of stub and line can be obtained by the impedance of resonator and the inverter. The new equivalent circuit of tapped-line can be simply applied of design of band-pass filter and leads to very good agreement compared with theoretical value. The coupled-line band-pass filter using equivalent circuit of tapped-line shows the insertion loss of 1.97 dB and the return loss of 18.5 dB at the center frequency of 5.8 GHz.

  • PDF

Design of Hair-Pin Band-Pass Filter Using New Equivalent Circuit of Tapped-Line (탭 선로의 새로운 등가 회로를 이용한 헤어핀 대역 통과 필터 설계)

  • Yun, Tae-Soon;Kwoun, Sung-Su;Hong, Tae-Ui;Lee, Jong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1150-1155
    • /
    • 2006
  • In this paper, the equivalent circuit of tapped-line that is applied in the band-pass filter is suggested and the value of an equivalent circuit is mathematically defined. An equivalent circuit of tapped-line is composed by open stub and transmission line that has negative electrical length, and the position of tapped-line and the value of resonator's length can be obtained by the impedance of resonator and the inverter. The new design method using equivalent circuit leads to very good agreement compared with theoretical value. The hair-pin band-pass filter using equivalent circuit of tapped-line shows the insertion loss of 1.1 dB and the return loss of 20 dB at the center frequency of 2 GHz.

Fabrication of a 2-2 Mode Piezocomposite and Derivation of its Equivalent Properties (2-2형 압전복합체 제작 및 등가 물성 도출)

  • Shin, Ho-Seop;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.8
    • /
    • pp.436-445
    • /
    • 2011
  • In this paper, equivalent properties of 2-2 mode piezocomposites were studied. Variation of the properties of 2-2 mode piezocomposites was analyzed by the finite element method, and the result was compared with experimental measurement data to confirm the validity of the analysis. The equivalent properties of a single phase material to represent the piezocomposite composed of PZT-5H and polymer were derived by the asymptotic averaging method. Accuracy of the derived equivalent properties was enhanced by minimizing the discrepancy between the impedance spectra of full 2-2 piezocomposite and equivalent single phase material resonators of various vibration modes by the least square method. The equivalent properties of 2-2 piezocomposites derived in this study can be utilized to the design of diverse acoustic sensors.

Capacity Spectrum Analysis using Equivalent SDOF Method and Equivalent Damping Method for RC Wall Structure (철근콘크리트 벽체구조물에 대한 등가단자유도 방법 및 등가 감쇠비 산정방법에 따른 역량스펙트럼해석)

  • Song, Jong-Keol;Jang, Dong-Hui;Kim, Hark-Soo;Chung, Yeong-Hwa
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.2
    • /
    • pp.169-187
    • /
    • 2008
  • Performance-based approaches as an alternative method of the existing force-based approach have gradually become recognized tools for the seismic design and evaluation. The maximum inelastic displacement response using capacity spectrum method (CSM) with elastic response spectrum is estimated from seismic response of equivalent linear system converted from nonlinear system. The purpose of this paper is to evaluate accuracy of capacity spectrum method using the equivalent SDOF methods of 4 types and the equivalent damping methods of 5 types for RC wall structure. In order to evaluate accuracy of capacity spectrum analysis, the shaking table test results for RC wall structures are compared with those by the capacity spectrum analysis. Also, the effect of bilinear capacity curves by two bilinear approximation methods for capacity spectrum analysis is compared.

Solution to Slow Down Myopia Progression

  • Jung, Ji-Won
    • Journal of Korean Clinical Health Science
    • /
    • v.8 no.1
    • /
    • pp.1386-1397
    • /
    • 2020
  • Purpose: To examine the effectiveness of various treatments; bifocal spectacles, orthokeratology, atropine, and time spent in outdoors; in slowing down the myopia progression for Asian adolescents (6-18age). Methods: The research focused on examining the most effective treatment in controlling myopia based on the literature sources that have been published. Through meta-analysis of various research papers that already has been done in this field, a lot of data was collected. For each treatment, the difference in axial length and spherical equivalent over time was measured and recorded. To quantitatively record the difference, both axial length and spherical equivalent was determined by value of control group value of treatment group. The paper compared the effectiveness of each treatment based on the data that was measured. Results: Adolescents who chose to spend time outdoors in order to slow down myopia progression had axial length difference of 0.03 mm and spherical equivalent difference of 0.17 D. Adolescents that used atropine had axial length difference of 0.36 mm and spherical equivalent difference of 0.92 D. Bifocal spectacle resulted in axial length difference of 0.21 mm and spherical equivalent difference of 0.59 D, and for orthokeratology 0.23 mm and 0.04 D, respectively. Axial length wise, myopia was most controlled by the atropine since there was a greatest difference between the group that got the treatment and the group that did not have the treatment. According to the spherical equivalent difference data, myopia was most controlled by atropine. Conclusion: Atropine showed the most effective result in controlling myopia among the four treatment. Again, compared to other three treatment, using atropine appeared to have greatest ability in slowing down myopia progression since adolescents who were treated with atropine had greatest difference from adolescents in the control group that had the same condition but didn't get the treatment. However, every treatment was only used for 2 or 3 years which is quite short time period to measure the long term effect of the four treatments. Also, since atropine is a pharmaceutical method to control myopia, it may harm adolescents' eyes compared to optical or environmental treatment.

Use of equivalent spring method for free vibration analyses of a rectangular plate carrying multiple three-degree-of-freedom spring-mass systems

  • Wu, Jia-Jang
    • Structural Engineering and Mechanics
    • /
    • v.21 no.6
    • /
    • pp.713-735
    • /
    • 2005
  • Due to the complexity of mathematical expressions, the literature concerning the free vibration analysis of plates carrying multiple three-degree-of-freedom (dof) spring-mass systems is rare. In this paper, the three degrees of freedom (dof's) for a spring-mass system refer to the translational motion of its lumped mass in the vertical ($\bar{z}$) direction and the two pitching motions of its lumped mass about the two horizontal ($\bar{x}$ and $\bar{y}$) axes. The basic concept of this paper is to replace each three-dof spring-mass system by a set of equivalent springs, so that the free vibration characteristics of a rectangular plate carrying any number of three-dof spring-mass systems can be obtained from those of the same plate supported by the same number of sets of equivalent springs. Since the three dof's of the lumped mass for each three-dof spring-mass system are eliminated to yield a set of equivalent springs, the total dof of the entire vibrating system is not affected by the total number of the spring-mass systems attached to the rectangular plate. However, this is not true in the conventional finite element method (FEM), where the total dof of the entire vibrating system increases three if one more three-dof spring-mass system is attached to the rectangular plate. Hence, the computer storage memory required by using the presented equivalent spring method (ESM) is less than that required by the conventional FEM, and the more the total number of the three-dof spring-mass systems attached to the plate, the more the advantage of the ESM. In addition, since manufacturing a spring with the specified stiffness is much easier than making a three-dof spring-mass system with the specified spring constants and mass magnitude, the presented theory of replacing a three-dof spring-mass system by a set of equivalent springs will be also significant from this viewpoint.