• 제목/요약/키워드: equivalent

검색결과 12,578건 처리시간 0.041초

Weiss형 등속조인트 볼 홈의 접촉응력평가 (Contact Stress Evaluations for the Ball Groove of Weiss Type Constant velocity joint)

  • 김완두;이순복
    • Tribology and Lubricants
    • /
    • 제5권2호
    • /
    • pp.60-67
    • /
    • 1989
  • For the life prediction and fatigue failure prevention of the constant velocity joint, the maximum equivalent stress and its location in depth from the contact area are essential. These values give the fundamental information to determine the depth of the surface hardening treatment at the contact area. Contact stresses are evaluated at the surface and subsurface of the ball groove of the Weiss type constant velocity joint. The maximum contact pressure and the maximum equivalent stress are obtained. The effects of various parameters such as the radius of ball groove, friction coefficient, and residual stress are studied. The maximum equivalent stress and the maximum contact pressure increase as the radius of the ball grove increases. The location of the maximum equivalent stress moves toward surface as the friction coefficient increases. It was also found that the maximum equivalent stress becomes minimum when the compressire residual stress is about 0.16 times of the maximum contact pressure.

Damping updating of a building structure installed with an MR damper

  • Woo, Sung-Sik;Lee, Sang-Hyun
    • Smart Structures and Systems
    • /
    • 제12권6호
    • /
    • pp.695-705
    • /
    • 2013
  • The purpose of this paper is to identify through experiments the finite element (FE) model of a building structure using a magnetorheological (MR) fluid damper. The FE model based system identification (FEBSI) technique evaluates the control performance of an MR damper that has nonlinear characteristics as equivalent linear properties such as mass, stiffness, and damping. The Bingham and Bouc-Wen models were used for modeling the MR damper and the equivalent damping increased by the MR damper was predicted by applying an equivalent linearization technique. Experimental results indicate that the predicted equivalent damping matches well with the experimentally obtained damping.

유리함수 근사를 이용한 등가회로 모델링 (Equivalent Circuit Modeling Applying Rational Function Fitting)

  • 백현;고재형;김군태;김형석
    • 정보통신설비학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-5
    • /
    • 2009
  • In this paper, we propose a method that applies Vector Fitting (VF) technique to the equivalent circuit model for RF passive components. These days wireless communication system is getting smaller and smaller. So EMI/EMC is an issue in RF. We can solve PI/SI (Power Integrity/Signal Integrity) that one of EMI/EMC problem apply IFFT for 3D EM simulation multiple with input signal. That is time consuming task. Therefore equivalent circuit model using RF passive component is important. VF schemes are implemented to obtain the rational functions. S parameters of the equivalent circuit model is compared to those of EM simulation in case of the microstrip line structure.

  • PDF

회전마찰감쇠기의 등가선형시스템에 관한 실험적 연구 (Experimental Study on Equivalent Linear System for Rotational friction Damper)

  • 김형섭;박지훈;민경원;이상현;이명규
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.296-303
    • /
    • 2004
  • In this study, equivalent linear damping and stiffness of a single-degree-of-freedom (SDOF) structure with a rotational friction damper are estimated using the result of experiments and compared with those obtained from non-linear time history analyses. First, the transfer function of the test model is constructed and then the equivalent stiffness and damping are calculated, using the half-power bandwidth (HPB) method. For comparative study, those properties are estimated based on stochastic theory in the time domain. Both equivalent linear systems identified from experiments and numerical analyses correspond well. Further, it is observed that there exists an optimal clamping force on the rotational friction damper from estimated equivalent damping.

  • PDF

능동 소자의 실장을 위한 새로운 DGS구조와 4-port등가 모델링 방법 연구 (A study of modeling novel DGS 4-port equivalent circuit for mounting active device)

  • 손창신;박준석;김형석;임재봉
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2004년도 하계학술대회
    • /
    • pp.386-389
    • /
    • 2004
  • This thesis complemented the weak points that the existing theses did not represented a phase characteristic as the equivalent circuit by applying 4-port simulation to DGS (Defected Ground Structure) characteristic and an equivalent circuit, which are the transmission line structure that has the defect made in the ground surface. We used a distribute device and a lumped device, obtained the equivalent circuit by applying the structure of balun to a discontinuous part. An indicated DGS (Defected Ground structure) is a dumbbells-shaped single defect, we indicated satisfying a magnitude and phase characteristics by applying this equivalent circuit.

  • PDF

Adaptive Frequency Sampling 을 이용한 등가회로 모델링 (Equivalent Circuit Modeling applying Adaptive Frequency Sampling)

  • 백현;김군태;강승택;김형석
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.281-284
    • /
    • 2009
  • In this paper, we propose a method that applies Adaptive Frequency Sampling(AFS) technique to the equivalent circuit model for RF passive components. Thes days wireless communication system is getting smaller and smaller. So EMI/EMC is an issue in RF. We can solve PI(Power Integrity)/SI(Signal Integrity) that one of EMI/EMC problem apply IFFT for 3D EM simulation multiple with input signal. That is time comuming task. Therefore equivalent circuit model using RF passive component is important. AFS schemes are implemented to obtain the rational functions. S parameters of the equivalent circuit moldel is compared to those of EM simulation in case of the microstrip line structure.

  • PDF

Wall Voltage Characteristics Simulated Using an Equivalent Circuit Model for AC POPs

  • Kim, Joon-Yub;Lim, Jong-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.317-320
    • /
    • 2003
  • As a convenient means for the characterization of the wall voltage and wall charge of AC PDPs during the sustain period, an equivalent circuit model for AC PDPs is presented. The equivalent circuit model for AC PDPs consists of capacitors and thyristors. The equivalent circuit model is based on the physical structure of the AC PDP and the I-V characteristic of the discharge space. This equivalent circuit model can be easily implemented in the standard simulators such as SPICE and can easily simulate the variation of the current, charge and voltage involved in AC PDPs as the supply voltage varies.

  • PDF

다중 다공판 시스템의 흡음계수 계산에 있어서 전기음향등가회로법의 오류 (The Error Involved in the Equivalent Electroacoustic Circuit Approach for the Estimation of the Absorption Coefficient of Multiple Layer Perforated Plate Systems)

  • Lee, Dong-Hoon;Kim, Wook;Kwon, Young-Pil
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.387.2-387
    • /
    • 2002
  • The equivalent electroacoustic circuit approach has been conventionally used for estimating the absorption coefficient of a single layer perforated plate system. When the single layer system is extended to the multiple layer ones, however, it is found that an analogy error has been involved in the equivalent electroacoustic parallel circuit approach proposed by previous researchers. The analogy error is demonstrated by the corrected equivalent electroacoustir circuit approach proposed en this study.

  • PDF

Analysis of three dimensional equivalent static wind loads of symmetric high-rise buildings based on wind tunnel tests

  • Liang, Shuguo;Zou, Lianghao;Wang, Dahai;Huang, Guoqing
    • Wind and Structures
    • /
    • 제19권5호
    • /
    • pp.565-583
    • /
    • 2014
  • Using synchronous surface pressures from the wind tunnel test, the three dimensional wind load models of high-rise buildings are established. Furthermore, the internal force responses of symmetric high-rise buildings in along-wind, across-wind and torsional directions are evaluated based on mode acceleration method, which expresses the restoring force as the summation of quasi-static force and inertia force components. Accordingly the calculation methods of equivalent static wind loads, in which the contributions of the higher modes can be considered, of symmetric high-rise buildings in along-wind, across-wind and torsional directions are deduced based on internal forces equivalence. Finally the equivalent static wind loads of an actual symmetric high-rise building are obtained by this method, and compared with the along-wind equivalent static wind loads obtained by China National Standard.

차륜/레일 기하학적 인자에 의한 등가답면구배 영향 분석 (Analysis on the Influence of Wheel/Rail Geometric Parameters on the Equivalent/Conicity)

  • 허현무;권성태
    • 한국철도학회논문집
    • /
    • 제8권5호
    • /
    • pp.490-494
    • /
    • 2005
  • The geometric parameters between wheel and rail change wheel/rail contact geometry characteristics, and this influence dynamic behavior of rolling stock. So, the selections of optimum geometric parameters between wheel and rail is important for planning of railway system. In this study, we have analyzed the influence of geometric parameters like wheel flange-back distance, gage, and rail inclination on the equivalent conicity relating to dynamic behavior. The analyses show the following results. The widening of wheel flange-back distanc, the decrement of gage increase the equivalent conicity and the increment of rail inclination show the sharp change of the equivalent conicity.