• 제목/요약/키워드: engineering technique

Search Result 22,457, Processing Time 0.04 seconds

MLFMA for Capacitance Extraction using Adaptive Triangular Mesh

  • Kim, Han;Ahn, Chang-Hoi
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.78-82
    • /
    • 2001
  • For fast capacitance computation, a simple mesh refinement technique on MLFMA(Multi-Level Fast Multipole Algorithm) is proposed The triangular meshes are refined mainly in the area which has heavy charge density. The technique is applied to the capacitance extraction of three dimensional conductors. The results show good convergence with comparable accuracy. An adaptive technique concerned with MLFMA is useful to reduce computation time and the number of elements without additional computational efforts in large three dimensional problems.

  • PDF

New Switching signal Pattern in AC Chopper (교류초퍼에서 새로운 스위칭 신호패턴)

  • Jang, Do-Hyun;Yeon, Jae-Eul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1267-1269
    • /
    • 2000
  • New switching signal pattern for four switches is proposed to prevent the shortage of PWM ac choppers. In the proposed technique, four signals to four power switches are generated without current transformer, while the conventional technique requires sensing the polarity of input voltage by voltage comparator and checking the direction of input current by the current transformer. The signal circuit built by the proposed technique is simple, and reduces also the switching loss.

  • PDF

A New Approach for Built-in Self-Test of 4.5 to 5.5 GHz Low-Noise Amplifiers

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • ETRI Journal
    • /
    • v.28 no.3
    • /
    • pp.355-363
    • /
    • 2006
  • This paper presents a low-cost RF parameter estimation technique using a new RF built-in self-test (BIST) circuit and efficient DC measurement for 4.5 to 5.5 GHz low noise amplifiers (LNAs). The BIST circuit measures gain, noise figure, input impedance, and input return loss for an LNA. The BIST circuit is designed using $0.18\;{\mu}m$ SiGe technology. The test technique utilizes input impedance matching and output DC voltage measurements. The technique is simple and inexpensive.

  • PDF

A Study on the Program of QC Technique Usage and Improvement Alternative in the QC Circle (품질관리분임조의 QC기법활용상 문제점과 개선방안)

  • 조남호;이근희
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.10 no.16
    • /
    • pp.107-112
    • /
    • 1987
  • This paper is to present the problem of QC technique usage and improvement alternative in the QC circle. First, in the selection theme, it must have easy relations of tangible/intangible effects through simple theme's title. And contents development most be consistency in tangible/intangible effects. Second, in the usage of QC technique, it is necessary to strengthen QC circle activity through QC circle education. So in the aspects of long-term period. Internal instruction is strengthened and, in the aspects of short-term period, internal evaluation is established.

  • PDF

Correlative Encoded Frequency Shift Keying (CEFSK) Modulation Technique

  • Lee, Kee-Hoon;Seo, Jong-Soo
    • Journal of Communications and Networks
    • /
    • v.6 no.1
    • /
    • pp.35-37
    • /
    • 2004
  • A new power and bandwidth efficient modem technique-Correlative Encoded FSK (CEFSK) is proposed. CEFSK has a spectral efficiency comparable to Gaussian filtered FSK (GFSK), and it achieves 0.7db Eb/N0 improvement at bit error rate (BER) of 1 * 10 -4 over GFSK in an additive white Gaussian noise (AWGN) channel and 3.0dB improvement in a Rayleigh fading channel

Considerations on High-gain Control of Feedback Linearizable Systems (궤환 선형화된 비선형 시스템의 고이득 제어기에 대한 고찰)

  • Shim, Hyung-Bo;Seo, Jin-H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1137-1139
    • /
    • 1996
  • Feedback Linearization technique needs the exact cancellation of nonlinearity which restricts its application to real environment. To overcome these shortcomings, High-pin feedback is good remedy to this problem. In this paper, we briefly survey the high-gain feedback control technique and show some conditions for applying this method to nonlinear systems. In order to use this technique in real situation, some properties of ${\varepsilon}$-bound and semi-global stabilization are discussed.

  • PDF

Resistive Grounding Technique of Heat Sink for Reducing Radiation Noise

  • Ahn, Chang-Hoi;Oh, JaeHyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1724-1728
    • /
    • 2014
  • Heat sink has been used to help an electrical device operate in normal temperature condition. But heat sink radiates unwanted electromagnetic wave, which may cause electromagnetic interference problem. A resistance loaded grounding technique is proposed to reduce electromagnetic wave radiation by a heat sink. Numerical simulations are accomplished to find optimal loading resistance. Also electromagnetic fields radiated by from a heat sink are measured and compared with the simulation results. The test results verify the usefulness of the proposed technique.

Zero-Correlation Linear Cryptanalysis of Reduced Round ARIA with Partial-sum and FFT

  • Yi, Wen-Tan;Chen, Shao-Zhen;Wei, Kuan-Yang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.280-295
    • /
    • 2015
  • Block cipher ARIA was first proposed by some South Korean experts in 2003, and later, it was established as a Korean Standard block cipher algorithm by Korean Agency for Technology and Standards. In this paper, we focus on the security evaluation of ARIA block cipher against the recent zero-correlation linear cryptanalysis. In addition, Partial-sum technique and FFT (Fast Fourier Transform) technique are used to speed up the cryptanalysis, respectively. We first introduce some 4-round linear approximations of ARIA with zero-correlation, and then present some key-recovery attacks on 6/7-round ARIA-128/256 with the Partial-sum technique and FFT technique. The key-recovery attack with Partial-sum technique on 6-round ARIA-128 needs $2^{123.6}$ known plaintexts (KPs), $2^{121}$ encryptions and $2^{90.3}$ bytes memory, and the attack with FFT technique requires $2^{124.1}$ KPs, $2^{121.5}$ encryptions and $2^{90.3}$ bytes memory. Moreover, applying Partial-sum technique, we can attack 7-round ARIA-256 with $2^{124.6}$ KPs, $2^{203.5}$ encryptions and $2^{152}$ bytes memory and 7-round ARIA-256 employing FFT technique, requires $2^{124.7}$ KPs, $2^{209.5}$ encryptions and $2^{152}$ bytes memory. Our results are the first zero-correlation linear cryptanalysis results on ARIA.

Experimental Study on Corrosion Detection of Aluminum Alloy Using Lamb Wave Mixing Technique (램파 혼합 기법을 이용한 알루미늄 합금의 부식 결함 검출에 대한 실험 연구)

  • Choi, Heeung;Lee, Jaesun;Cho, Younho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.919-925
    • /
    • 2016
  • In this study, the Lamb wave mixing technique, which is basised on advanced research on the nonlinear bulk wave mixing technique, is applied for corrosion detection. To demonstrate the validity of the Lamb wave mixing technique, an experiment was performed with normal and corroded specimens. Comparison group in an experimentation are selected to mode and frequency with dominant in-plane displacement and out-of-plane displacement of Lamb waves. The results showed that the Lamb wave mixing technique can monitor corrosion defects, and it has a trend similar to that of the conventional Lamb wave technique. It was confirmed that the dominant displacement and mode matching the theory were generated. Flaw detectability is determined depending on displacement ratio instead of using the measurement method and mode selection.

Theoretical Analysis of Phase Detector Technique for the Measurement of Cell Membrane Capacitance During Exocytosis (세포외 분비시 막 캐패시턴스를 측정하기 위한 위상감지법(phase detector technique)의 이론적 분석.)

  • Cha, Eun-Jong;Goo, Yong-Sook;Lee, Tae-Soo
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.43-57
    • /
    • 1992
  • Phase detector techique provides a unique probe to membrane recycling phenomenon by enabling dynamic monitoring of cell membrane capacitance. However, it has inherent errors due to constant changes in measurement environments. The present study analyzed several error sources to develope application criteria of this technique. and the following was found based on a theoretical analysis. The initial phase angle has to be appropriately selected to minimize the error due to perturbation of access and membrane conductances. Excitation frequency is also important to determine the initial phase angle. However. deviation of the phase angle from a predetermined initial value during the measurement period does not affect capacitance estimation to a significant degree. Despite an appropriate initial phase selection an error in scaling factor is expected for a large increase in capacitance during exocytosis. which may be overcome by iteratively correcting the scaling factor over the measurement period. These results will provide a useful guideline in practical application of this technique.

  • PDF