• Title/Summary/Keyword: engineering room

Search Result 4,584, Processing Time 0.039 seconds

Effects of the sound field characteristics of the receiving room on heavy-weight impact sound measurement generated by impact ball (임팩트 볼에 의한 중량충격음 측정에 있어서 수음실 음장특성의 영향)

  • Yoo, Seung-Yup;Lee, Sin-Young;Jeong, Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.622-625
    • /
    • 2006
  • This study is a fundamental investigation for standardization of the heavy-weight floor impact measuring method by the impact ball. The distribution chrematistics of floor impact sound level and reverberation time in a receiving room of the testing building for floor impact sound were measured with variations of number and arrangement of the sound-absorbing materials. Total 8 cases were investigated. The distribution of the floor impact sound level($L_{i,\;Fmax}$) was measured at 30 points with same intervals. The absorption coefficient of the room is 0.10 in case of installation of 6 absorbing materials and 0.02 in case of non-installation. The distribution shape of the impact sound pressure level was similar to the result of the bang machine driving at the measured frequency range. However, the overall reduction of the impact sound level investigated in the 125 to 500 Hz shows that the sound absorption characteristics of the receiving room actually affects the result of the heavy-weight impact measurement.

  • PDF

A Measurement and Evaluation on the Indoor Thermal Conditions in Summer of a New Training ship (신조 운항실습선의 여름철 실내 온열환경 실측평가)

  • Shin, Dong-Keol;Lee, Jin-Uk;Lee, Hyong-Ki;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.276-283
    • /
    • 2008
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those which are supplied and controlled by marine HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured like previous report on a newly-launched training ship during 25th through 27th of July, 2007. Followings are the results of this study. (1)The air supply volumes to each cabins are measured 250CMH(Recreation room), 800CMH(Conference room), 1.000CMH(Bridge), 5,100CMH(Lecture room) respectively. (2)The temperatures are maintained at $21{\sim}27^{\circ}C$ in almost cabins through measuring period, but the temperatures are fluctuated over ${\pm}4^{\circ}C$ at the bridge and conference room. (3)The relative humidities are shown between $40{\sim}60%$ known as comfort conditions, but the conference room is needed to dehumidified because of over 70% humidity. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of temperature diversities, only 32% among the measured data are satisfied with the comfort standard range proposed by ASHREA.

A Study on the Effect of the Environmental Improvement in the Diagnostic Radiography Room on Patients (진단방사선과 검사실의 환경개선이 환자에게 미치는 영향에 관한 연구)

  • Kweon, Dae Cheol;Hong, Sung Man;Kim, Dong Sung;Park, Peom
    • Quality Improvement in Health Care
    • /
    • v.9 no.1
    • /
    • pp.90-100
    • /
    • 2002
  • Background : This study was attempted to provide us with basic data on how to environmental improvement with patients for examination, and to offer them better treatment. This study was performed to compare the patients, perception between before and after improvement in the diagnostic radiography room. Methods : The data was collected by interviewing 75 patients who underwent the radiography under the diagnostic radiology at Seoul National University Hospital in Korea. The interview ran from August 9 to October 18, 1999. Data were analyzed by percentage and paired t-test. SD(Semantic Differential) method was composed of adjective 13 words. Results : Patients were attending the elementary schools in the Seoul residents. There was no significant difference in kindness unkindness dimension and were significant differences in other dimensions. The mean score of response level to present room was 3.67 and that of improvement room was 2.16. Conclusions : The results of this study suggest a radiography room plan which is considering emotional aspect of children.

  • PDF

Effect of Acoustic Reflector's Surface Density on Sound Absorption Characteristics and Stage Acoustics (음향 반사판의 밀도별 흡음특성 및 무대음향에의 영향)

  • Kim, Young-Sun;Jeong, Jeong-Ho;Jeon, Jin-Yong;Kim, Myeong-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.429-436
    • /
    • 2012
  • In concert halls and auditoriums, acoustic reflector and stage enclosure is one of the main factors on the room and stage acoustic characteristics. As a stage enclosure and acoustic reflector honey comb based light-weight reflector is widely used, because it is easy to install. However, there was not enough research on the surface density effect on room and stage acoustics. In this study, sound absorption coefficient tests on three kinds of wooden acoustic reflectors with different surface density were conducted. Surface density of acoustic reflector was changed from 11 kg/$m^2$ to 41 kg/$m^2$. For the low frequency excitation, sub-woofer was used with omnidirectional loud-speaker simultaneously. From the experiments, it was found that sound absorption coefficient below 250 Hz band was decrease by the increment of surface density. In order to check the influence of the surface density on room and stage acoustic parameters, room acoustic simulation was conducted with sound absorption coefficients, which were tested in reverberation chamber. By the increment of surface density of acoustic reflector, RT(reverberation time) and EDT(early decay time) were increased. Also, ST(stage support) was improved in low frequency bands.

A Numerical Study on the Flow Characteristics through an Industrial Safety Relief Valve (산업용 안전 릴리프밸브 유동특성에 관한 수치연구)

  • Kang, Sang-Mo;Lee, Bong-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.696-704
    • /
    • 2009
  • In this paper, the flow characteristics through an industrial safety relief valve used to protect the crankcase room in a large-sized marine engine have been numerically investigated using the moving-mesh strategy. With the room pressure higher than the cracking one, the spring-loaded disc becomes open and then the air in the room blows off into the atmosphere, resulting in the reduction of the room pressure and then the shutoff of the disc. Numerical simulations are performed on the compressible air flow through the relief valve (${\phi}160mm$) with the initial room pressure (0.11 bar or 0.12bar) higher than the cracking one (0.1 bar). The numerical method has been validated by comparing the results with the empirical ones. Results show that the disc motion and flow characteristics can be successfully simulated using the moving-mesh strategy and depend strongly on the spring stiffness and the flow passage shape. With increasing spring stiffness, the maximum disc displacement decreases and thus the total disc-opening time also decreases. In addition, the flow passage shape makes a significant effect on the velocity and direction of the flow.

An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses (전통주택의 차음성능 평가에 관한 실험적 연구)

  • Kim, Sun-Woo;Lee, Tai-Gang;Kim, Hyung-Ryul;Kim, Hang;Choi, Eun-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.

Investigation on Mechanical Property and Adhesion of Oxide Films Formed on Ni and Ni-Co Alloy in Room and High Temperature Environments

  • Oka, Yoshinori I.;Watanabe, Hisanobu
    • Corrosion Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.145-151
    • /
    • 2008
  • Material degradation such as high temperature oxidation of metallic material is a severe problem in energy generation systems or manufacturing industries. The metallic materials are oxidized to form oxide films in high temperature environments. The oxide films act as diffusion barriers of oxygen and metal ions and thereafter decrease oxidation rates of metals. The metal oxidation is, however, accelerated by mechanical fracture and spalling of the oxide films caused by thermal stresses by repetition of temperature change, vibration and by the impact of solid particles. It is therefore very important to investigate mechanical properties and adhesion of oxide films in high temperature environments, as well as the properties in a room temperature environment. The oxidation tests were conducted for Ni and Ni-Co alloy under high temperature corrosive environments. The hardness distributions against the indentation depth from the top surface were examined at room temperature. Dynamic indentation tests were performed on Ni oxide films formed on Ni surfaces at room and high temperature to observe fractures or cracks generated around impact craters. As a result, it was found that the mechanical property as hardness of the oxide films were different between Ni and Ni-Co alloy, and between room and high temperatures, and that the adhesion of Ni oxide films was relatively stronger than that of Co oxide films.

Numerical Simulation of the Odor Spreading in a Factory (공장에서 퍼지는 냄새에 관한 수치계산적 연구)

  • Vincent, Lijo;Song, Eun-Hwa;Nam, Hyun-Kyu;Shin, Choon-Sik;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2540-2543
    • /
    • 2008
  • Liquid crystal displays (LCD's) are continuously coated with some chemicals in the clean room of a factory. Spreading of these chemicals is causing serious problems both in controlling clean room quality as well as to the workers inside the factory. It is required to alleviate or properly control the offensive odor which is mainly composed of propylene glycol mono ethyl acetate, novolak resin and photo active compound. The control strategy employed is to bleed the offensive odor gas out the clean room. A full scale 3D CFD model was created with anisotropic porous media, chemical species transport with no volumetric reaction, and thermal diffusion with propane gas (tracer gas) to simulate the odor spreading. A segregated implicit solver with standard k-$\varepsilon$ model is employed. The detailed CFD analysis made it possible to develop an effective method of ventilating the coater room and optimizing their capacities.

  • PDF

Measurement of missing video frames in NPP control room monitoring system using Kalman filter

  • Mrityunjay Chaubey;Lalit Kumar Singh;Manjari Gupta
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.37-44
    • /
    • 2023
  • Using the Kalman filtering technique, we propose a novel method for estimating the missing video frames to monitor the activities inside the control room of a nuclear power plant (NPP). The purpose of this study is to reinforce the existing security and safety procedures in the control room of an NPP. The NPP control room serves as the nervous system of the plant, with instrumentation and control systems used to monitor and control critical plant parameters. Because the safety and security of the NPP control room are critical, it must be monitored closely by security cameras in order to assess and reduce the onset of any incidents and accidents that could adversely impact the safety of the NPP. However, for a variety of technical and administrative reasons, continuous monitoring may be interrupted. Because of the interruption, one or more frames of the video may be distorted or missing, making it difficult to identify the activity during this time period. This could endanger overall safety. The demonstrated Kalman filter model estimates the value of the missing frame pixel-by-pixel using information from the frame that occurred in the video sequence before it and the frame that will occur in the video sequence after it. The results of the experiment provide evidence of the effectiveness of the algorithm.

A study on conceptual evaluation of structural stability of room-and-pillar underground space (주방식 지하공간의 구조적 안정성 평가개념 정립에 관한 연구)

  • Lee, Chulho;Chang, Soo-Ho;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.6
    • /
    • pp.585-597
    • /
    • 2013
  • In this study, in order to evaluate stability of the room-and-pillar underground structure, a series of preliminary numerical analyses were performed. Design concept and procedure of an underground structure for obtaining a space are proposed, which should be different from structural design for the room-and-pillar in mine. With assumed material properties, a series of numerical analyses were performed by varying size ratios of room and pillar and then the failure modes and location at yielding initiation were investigated. From the results, relationship between the ratio of pillar width to the roof span (w/s) and overburden pressure at failure initiation shows a relatively linear relation, and the effect of w/s on structural stability is much more critical than the ratio of pillar width and height (w/H) which is a crucial parameter in design of the room-and-pillar mining. It means that roof tensile failure and shear failure at shoulder and pillar are necessary to be considered together for confirming overall structural stability of the room-and-pillar structure, rather than considering the pillar stability only in mining. Failure modes and location at failure initiation were varied with respect to the ratio of room and pillar widths. Therefore, it is necessary to simultaneously consider stability of both roof span and pillar for design of underground structure by the room-and-pillar method.