• Title/Summary/Keyword: engineering and environmental application

Search Result 3,585, Processing Time 0.03 seconds

Axial Behavior of Concrete Cylinders Confined with FRP Wires (FRP 와이어 보강 콘크리트 공시체의 압축거동)

  • Cho, Baiksoon;Lee, Jong-Han;Choi, Eunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1765-1775
    • /
    • 2013
  • The application of FRP wire as a mean of improving strength and ductility capacity of concrete cylinders under axial compressive load through confinement is investigated experimentally in this study. An experimental investigation involves axial compressive test of three confining amounts of FRP wire and three concrete compressive strengths. The effectiveness of FRP wire confinement on the concrete microstructure were examined by evaluating the internal concrete damage using axial, circumferential, and volumetric strains. The axial stress-strain relations of FRP wire confined concrete showed bilinear behavior with transition region. It showed strain-hardening behavior in the post-cracking region. The load carrying capacity was linearly increased with increasing of the amount of FRP wire. The ultimate strength of the 35 MPa specimen confined with 3 layer of FRP wire was increased by 286% compared to control one. When the concrete were effectively confined with FRP wire, horizontal cracks were formed by shearing. It was developed from sudden expansion of the concrete due to confinement ruptures at one side while the FRP wire was still working in hindering expansion of concrete at the other side of the crack. The FRP wire failure strains obtained from FRP wire confined concrete tests were 55~90%, average 69.5%, of the FRP wire ultimate uniaxial tensile strain. It was as high as any other FRP confined method. The magnitude of FRP wire failure strain was related to the FRP wire effectiveness.

A Study of the Application of Earthquake Early Warning System for the Enhancements in Protective Action by Korea National Park (국립공원의 지진 대응 체계 개선을 위한 지진 조기경보 시스템의 적용에 관한 연구)

  • Yang, Eomzi;Ha, Seong Jun;Kim, Won Kyung;Yun, Tae Sup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.439-448
    • /
    • 2018
  • Conventional Earthquake Early Warning System (EEWS) detects the propagated P-wave from epicenter which should be achieved within 5 seconds to provide seconds to minutes of warning, allowing people to prepare for protective actions. EEWS in Korea is currently capable of providing a warning within 50 seconds after the primary P-wave detection, however, it is well-known that earthquake warning systems operating around Korean National Parks (KNP) have limited capability to fully monitor earthquake events. This study, therefore, presents a strategy to quantify the potential vulnerability to earthquake hazards by superimposing the distribution of Korea Integrated Seismic System (KISS) and the discretized map of KNP. Total 22 national parks are evaluated, and the results suggest that the improvement of the on-site systems should be necessitated for Gyoengju, Gyeryongsan, Songnisan, Gayasan, and Deogyusan national parks, whereas enhancement of regional systems is required for Bukhansan national park.

Corrosion Resistance of Blended Concrete and Its Application to Crack Healing (혼합 콘크리트의 부식 저항성과 균열 치유 적용)

  • Lee, Chang-Hong;Kim, Tae-Sang;Song, Ha-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.689-696
    • /
    • 2009
  • In this study, electro-deposition method was applied to heal cracks in various blended concrete. The performance of the method was indirectly monitored by measuring impressed voltage, electrolyte, galvanic current monitoring, linear polarization resistance, and directly by image analysis of the cracks. The indirect and direct monitoring values are compared to develop guidelines for relating the indirect measures to actual crack healing. As a result, It was found that impressed voltage was convergence to 2.9V after 20000 minutes. From the galvanic current test results of artificial crack healing, the corrosion resistance showed that the order of 0.4 $>$ 0.6 $>$ 0.5 water to cement ratio. Furthermore, in view of binder, the corrosion resistance order was calculated OPC $>$ 60%GGBS $>$ 10%SF $>$ 30%PFA. Finally, It was found that 76.47% of healed crack surface calculated from the artificial crack healing technique using electrochemical deposition method.

A Probabilistic Determination of the Active Storage Capacity of A Reservoir Using the Monthly Streamflows Generated by Stochastic Models (월유하량(月流下量)의 추계학적(推計學的) 모의발생자료(模擬發生資料)를 사용(使用)한 저수지(貯水池) 활용(活用) 저수용량(貯水容量)의 확률론적(確率論的) 결정(決定))

  • Yoon, Yong Nam;Yoon, Kang Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.6 no.3
    • /
    • pp.63-74
    • /
    • 1986
  • A methodology for the probabilistic determination of active storage capacity of an impounding reservoir is proposed with due considerations to the durations and return periods of the low flow series at the reservoir site. For more reliable probabilistic analysis the best-fit stochastic generation model of Monte Carlo type was first selected for the generation of monthly flow series, the models tested being the Month Carlo Model based on the month-by-month flow series (Monte Carlo-A Type), Monte Carlo Model based on the standardized sequential monthly flow series (Monte Carlo-B Type), and the Thomas-Fiering Model. Monte Carlo-B Model was final1y selected and synthetic monthly flows of 200 years at Hong Cheon dam site were generated. With so generated 200 years' monthly flows partial duration series of low flows were developed for various durations. Each low flow series was further processed by a nonsequential mass analysis for specified draft rates. This mass analysis furnished the storage-draft-recurrence interval relationship which gives the reservoir storage requirement for a specified water demand from the reservoir during a drought of given return period. Illustrations are given on the application of these results in analyzing the water supply capacity of a particlar reservoir, existing or proposed.

  • PDF

Applicability Evaluation of Probability Matching Method for Parameter Estimation of Radar Rain Rate Equation (강우 추정관계식의 매개변수 결정을 위한 확률대응법의 적용성 평가)

  • Ro, Yonghun;Yoo, Chulsang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1765-1777
    • /
    • 2014
  • This study evaluated PMM (Probability Matching Method) for parameter estimation of the Z - R relation. As a first step, the sensitivity analysis was done to decide the threshold number of data pairs and the data interval for the development of a histogram. As a result, it was found that at least 1,000 number of data pairs are required to apply the PMM for the parameter estimation. This amount of data is similar to that collected for two hours. Also, the number of intervals for the histogram was found to be at least 100. Additionally, it was found that the matching the first-order moment is better than the cumulative probability, and that the data pairs comprising 30 to 100% are better for the PMM application. Finally, above findings were applied to a real rainfall event observed by the Bislsan radar and optimal parameters were estimated. The radar rain rate derived by applying these parameters was found to be well matched to the rain gauge rain rate.

Application of a Fictitious Axial Force Factor to Determine Elastic and Inelastic Effective Lengths for Column Members of Steel Frames (강프레임 기둥 부재의 탄성 및 비탄성 유효좌굴길이 산정을 위한 가상축력계수의 적용)

  • Choi, Dong Ho;Yoo, Hoon;Lee, Yoon Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2A
    • /
    • pp.81-92
    • /
    • 2010
  • In design of steel frames, it is generally believed that elastic system buckling analysis cannot predict real behaviors of structures, while inelastic system buckling analysis can give informative buckling behaviors of individual members considering inelastic material behavior. However, the use of Euler buckling equation with these system buckling analyses have the inherent problem that the methods evaluate unexpectedly large effective lengths of members having relatively small axial forces. This paper proposes a new method of obtaining elastic and inelastic effective lengths of all members in steel frames. Considering a fictitious axial force factor for each story of frames, the proposed method determines the effective lengths using the inelastic stiffness reduction factor and the iterative eigenvalue analysis. In order to verify the validity of the proposed method, the effective lengths of example frames by the proposed method were compared to those of previously established methods. As a result, the proposed method gives reasonable effective lengths of all members in steel frames. The effect of inelastic material behavior on the effective lengths of members was also discussed.

The study of Application of Drought Index Using Measured Soil Moisture at KoFlux Tower (KoFlux 타워에서 관측된 토양수분 값을 이용한 가뭄지수 활용에 관한 연구)

  • Kim, Sooyoung;Jo, Hwan Bum;Lee, Seung Oh;Choi, Minha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6B
    • /
    • pp.541-549
    • /
    • 2010
  • While the number of rainy days is decreasing, the mean annual precipitation is increasing due to abnormal climate changes caused by the global warming in Korea. Owing to the biased-concentration of rainfall during specific short terms, not only flood but also drought becomes more and more serious. From the literature, it is easily found that previous studies about flood have been intensively conducted. However, previous studies about drought have been performed rarely. This study conducted the comparison between two representative drought indexes calculated from soil moisture and precipitation. Study area was Haenam-gun, Jeollanam-do in Korea. Soil Moisture Index(SMI) was calculated from soil moisture data while the Standardized Precipitation Index(SPI) and the Palmer Drought Severity Index(PDSI) were calculated from meteorological data. All monthly data utilized in this study were observed at the KoFlux Tower. After the comparative analysis, three indexes showed similar tendency. Therefore, it is thought that the drought index using soil moisture measured at the KoFlux Tower is reasonable, which is because the soil moisture is immediately affected by all the meteorological factors.

Estimation of the Shaft Resistance of Rock-Socketed Drilled Shafts using Geological Strength Index (GSI를 이용한 암반에 근입된 현장타설말뚝의 주면저항력 산정)

  • Cho, Chun Whan;Lee, Hyuk Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1C
    • /
    • pp.25-31
    • /
    • 2006
  • It is common to use the unconfined compressive strength (UCS) of intact rock to estimate the shaft resistance of rock socketed drilled shaft. Therefore the most design manuals give a guide to use the UCS of rock core to estimate the shaft resistance of rock-socketed drilled shaft. Recently, however the design manuals for highway bridge (KSCE, 2001) and of AASHTO (2000) were revised to use the UCS of rock mass with RQD instead of the UCS of rock core so that the estimated resistance could be representative of field conditions. Questions have been raised in application of the new guide to the domestic main bed rock types. The intrinsic drawbacks in terms of RQD were comprised in the questions, too. As the results, in 2002 the new guide in the design manual for highway bridge (KSCE, 2001) were again revised to use the UCS of rock core to estimate the shaft resistance of rock-socketed drilled shafts. In this paper, various methods which can estimate the UCS of rock mass from intact rock core were reviewed. It seems that among those, the Hoek-Brown method is very reliable and practical for the estimation of the UCS of rock mass from rock cores. As the results, using the Hoek-Brown failure criterion a modified guide for the estimation of the shaft resistance of rock-socketed drilled shafts was suggested in this paper. Through a case study it is shown that the suggested method gives a good agreement with the measured data.

A Study on the Extraction of Monasil PCA using Liquid CO2 (액체 이산화탄소 이용한 Monasil PCA 추출에 대한 연구)

  • Cho, Dong Woo;Oh, Kyoung Shil;Bae, Won;Kim, Hwayong;Lee, Kab-Soo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.684-689
    • /
    • 2012
  • Poly(acrylic acid) (PAA) microspheres is one of the widely-used polymeric materials for the bio-field application and the electric materials. For the synthesis of PAA microspheres, the polymerization technique using surfactants is applied. After the synthesis, the purification and separation processes are required for the removal of surfactant. When general organic solvents were used, many problems, such as huge amount of waste solvent, additional separation processes, and the possibility of residual media, were occurred. Thus, High-pressure Soxhlet extraction using liquid $CO_2$ was developed to solve these problems. In this study, High-pressure Soxhlet extraction of the synthesized PAA microspheres using liquid $CO_2$ was conducted for the removal of Monasil PCA which is used for the dispersion polymerization of acrylic acid in compressed liquid Dimethyl ether (DME). The morphology of the extracted PAA particles was checked by field emission scanning electron microscopy (FE-SEM) and the residual concentration of Monasil PCA was analyzed by inductively coupled plasma - Optical Emission Spectrometer (ICP-OES). For studying the effect of the solvent effect, Soxhlet extraction was conducted using n-hexane, liquid DME, and liquid $CO_2$. In case of n-hexane, some extracted PAA microspheres were produced. However, deformation was also occurred due to the high thermal energy of n-hexane vapor. Liquid DME could not remove Monasil PCA. When using liquid $CO_2$, the extracted PAA microspheres which were free for the residual solvent were produced without deformation. For finding the optimum operating condition, high-pressure Soxhlet extraction was conducted for 8 hours with changing the temperature of reboiler and condenser. When the extractor temperature is $19.6{\pm}0.2^{\circ}C$ and the pressure is $51.5{\pm}0.5$ bar, the best removal efficiency was obtained.

A Study on the Nightsoil Treatment by BFB (BFB에 의한 분뇨처리(糞尿處理)의 연구(研究))

  • Kim, Hwan Gi;Lee, Young Dong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.1-15
    • /
    • 1983
  • This paper has concentrated on estimating the possibility and mathematical analysis for the application of BFB to the treatment of nightsoil with low dilution rate. The experiment for the study of this purpose was conducted by continuous type reactor at $20^{\circ}C$, varying F/M ratio from 0.12 to 0.37 and dilution ratio from 2 to 10, and in it provided matted reticulated polypropylene sheets for the solid supports. The obtained results showed that the application of BFB to the treatment of nightsoil would be more effective than any other biological treatment process. Also, it has observed that the optimum dilution ratio was about 5 times and the optimum HRT was about 17 hours, and then it was estimated that the reactor volume and the quantity of weak water could be reduced to the extent of 70 percent and 80 percent. The experimental results of BFB could be analysed by the mathematical models applied to complete mixing activated sludge process. The substrate removal rates which were obtained by McKinney's($K_m$) and EcKenfelder's($K_e$) equation was 1.784/hr and $2.0{\times}10l/mg{\cdot}day$, and substrate was removed very rapidly compared to those of conventional type biological treatment processes. The biomass yield coefficient($a_5$), the endogeneous respiration rate(b), the synthesis oxygen demand rate($a{_5}^{\prime}$), and the endogeneous respiration oxygen demand rate(b') were 0.349, 0.0237/day, 0.495 and 0.0336, respectively.

  • PDF