• Title/Summary/Keyword: energy space

Search Result 3,298, Processing Time 0.028 seconds

A study on Tensile performance of Energy Absorbing Bolts in Space Frame (스페이스프레임에 사용되는 에너지 흡수형 볼트의 인장성능연구)

  • Lee, Sung-Min;Kim, Min-Sook;Choi, Jung-Sam;Kang, Chang-Hoon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.6
    • /
    • pp.53-60
    • /
    • 2007
  • The hole for the insertion of the pin in the shank is exist at ball joint connection of the space frame. It brings about the brittle fracture caused by stress concentration. Consequently it cannot expect the deformation performance or energy absorption performance from ball joint connection. In this study we developed a new connection details which will increase the plastic deformation performance at ball joint connection and can absorb the error in construction, which expect the plastic deformation performance at the reduced shank without brittle fracture at the screw of bolt and pin. Also it's capacity is verified by the performance in numerical analysis and test. We confirmed bolt's plastic deformantion performance through controled shank and pin's area.

  • PDF

Sound Control of Structural-acoustic Coupling System Using Optimum Layout of Absorbing Material and Damping Material (흡음재 및 제진재의 최적배치를 이용한 구조-음향 연성계의 소음제어)

  • Kim, Dong-Young;Hong, Do-Kwan;Ahn, Chan-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.2 s.95
    • /
    • pp.161-168
    • /
    • 2005
  • The absorbing material is mostly used to changing the acoustic energy to the heat energy in the passive control, and that consists of the porous media. That controls an air borne noise while the stiffened plates, damping material and additional mass control a structure borne noise. The additional mass can decrease the sound by mass effect and shift of natural frequency, and damping material can decrease the sound by damping effect. The passive acoustic control using these kinds of control materials has an advantage that is possible to control the acoustic in the wide frequency band and the whole space at a price as compared with the active control using the various electronic circuit and actuator. But the space efficiency decreased and the control ability isn't up to the active control. So it is necessary to maximize the control ability in the specific frequency to raise the capacity of passive control minimizing the diminution of space efficiency such an active control. Therefore, the characteristics of control materials and the optimum layout of control materials that attached to the boundary of structure-acoustic coupled cavity were studied using sequential optimization on this study.

Analysis of Environment-friendly features in the unit of Environment-friendly Certificated Apartment (친환경인증아파트 단위주거의 친환경적 계획요소 분석)

  • Lee, Song-Hyun;Hwang, Yeon-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.6 s.59
    • /
    • pp.150-158
    • /
    • 2006
  • The purpose of this study is to evaluate environment-friendly planning feature in Environment-friendly Certificated apartments and to use the basic planning data of housing. Seven Environment-friendly Certificated apartments have been analyzed. The findings of this study are as follows: Environment-friendly planning features are categorized into 4 items; floor planning feature, material planning feature, universal planning feature and environmental planning feature. Among floor planning features, natural sunlight, built-in closets, and differentiated floor plans are well considered, but the flexible floor plan for resident's lifestyle and green space are lack. Among material planning features, environment-friendly finishing materials, environment-friendly products and energy-efficient double-pane windows are well considered, but implementation for resource savings using recycled materials are lack. Among universal design planning features, removal of threshold and installation of safety device in bathroom are not well considered. Among environmental planning features, usage of alternative energy like solar energy are not applied. The environment-friendly planning features in interior space should be introduced in diverse ways.

A Study on Analysis of Space Evaluation Using the Luminance Distribution Images (휘도분포영상을 이용한 공간평가분석에 관한 연구)

  • Han, Sang-Pil;Kim, Jong-Youn;Cho, Nam-Cheol;Yi, Yong-Kyu;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.76-81
    • /
    • 2013
  • In our former study, we proposed that the AC-Model might be applied to various conditions. And we also introduced the method for daylighting that it was possible to reduce discomfort glare and to improve visual impressions as the supplementary type and blind-control type on the compound lighting. The purpose of this study was to examine the relationship between physical elements and psychological evaluation of lighting space. The study was made using an full-size space, which were equipped with various luminaries. We investigated the relationship between subjective evaluation and characteristics of light distribution and showed the high correlation between the evaluation rating and luminance distribution over whole room.

Validation of Generalized State Space Averaging Method for Modeling and Simulation of Power Electronic Converters for Renewable Energy Systems

  • Rimmalapudi, Sita R.;Williamson, Sheldon S.;Nasiri, Adel;Emadi, Ali
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.231-240
    • /
    • 2007
  • This paper presents an advanced modeling and simulation technique applied to DC/DC power electronic converters fed through renewable energy power sources. The distributed generation (DG) system at the Illinois Institute of Technology, which employs a phase-l system consisting of a photovoltaic-based power system and a phase-2 system consisting of a fuel cell based primary power source, is studied. The modeling and simulation of the DG system is done using the generalized state space averaging (GSSA) method. Furthermore, the paper compares the results achieved upon simulation of the specific GSSA models with those of popular computer aided design software simulations performed on the same system. Finally, the GSSA and CAD software simulation results are accompanied with test results achieved via experimentation on both, the PV-based phase-l system and the fuel cell based phase-2 power system.

Analysis of the Residence Time Distribution for a Variable Feed Rate System by the State-space Equation (가변 유입유량 공정시스템에 대한 상태방정식을 이용한 체재시간분포 해석)

  • Moon, Jinho;Jung, Sung-Hee;Kim, Jong-Bum
    • Journal of Radiation Industry
    • /
    • v.4 no.1
    • /
    • pp.85-89
    • /
    • 2010
  • The radioactive experiments are carried out for diagnosis of a variety of industrial processes in terms of the operation condition and the efficiency by measuring the residence time distribution. However, it is not easy to interpret the residence time distribution using the conventional methods when the flow rate is not constant and a number of processes are coupled in a complicated manner. In these cases, they can be analyzed by describing the system with mathematical models that can be defined with the state-space equations. In this paper, the residence time distribution of sludge was measured with a radiotracer, $^{46}Sc-EDTA$, in the digester of which the flow rate varies with time. The digester was assumed as a linear time variant system since the flow rate changed during the experiment and the operation efficiency of the digester was calculated by applying the state-spae equations.

Aerodynamics Characteristics of Hypersonic Vehicle in Near Space

  • Wu, Dingyi;Liu, Zhenxia;Xiao, Hong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.503-505
    • /
    • 2008
  • The purpose of the current study is to examine the aerodynamic characteristics of two hypersonic vehicles in near space. One is derived from waverider shape, and the other from liftbody. The objective of this study are threefold. The first is to creat an computational database for hypersonic vehicle configurations. The second is to examine the effects of individual vehicle components on hypersonic configurations and to determine the differences in aerodynamic characteristics that result from integrating all vehicle components. The third objective is to evaluate the controllability of each of the fully integrated vehicles and the effectiveness of the control surface design. These objectives were accomplished using DSMC solutions and aerodynamic code developed in Northwestern Polytechnical University. The results are analyzed also in three sections. First, the results of the waverider shape and liftbody shape without integrated vehicle components are presented. Second, the results of adding aircraft components to the waverider shape and liftbody shape are presented. Finally, the aerodynamic characteristics of the fully integrated waverider-derived configuration and liftbody-derived configuration are examined and compared with those of the pure waverider shape and liftbody shape. Comparation between fully integrated waverider-derived configuration and liftbody-derived configuration are also presented in this paper.

  • PDF

Energy Theme Park Design in Yeong-Heung Island (영흥 에너지 테마파크 조경설계)

  • Lee Shi-Young;Cho Kwang-Young;Kim Shin-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.2 s.109
    • /
    • pp.100-110
    • /
    • 2005
  • The Korea South-East Power Co., Ltd.(KOSEP) held a design competition for Energy Theme Park at Yeong-Heung power plant in October, 2004. The site is located in 980-1 Oe-ri, Yeong-Heung myun, OngJin gun, Incheon City and has an area of $54,450m^2$. Design objectives of KOSEP were to make environmentally sustainable space, to build a symbolic and gathering place for community members and visitors, to make a tourist spot of Yeong-Heung Island linked with adjacent sight spots in OngJin gun, and to elevate an identity and status of the KOSEP by creating a landscape correspondent to the concept of the building design. The spatial concept of this project was developed by expressing a circular course of energy, named 'energy circle' and accounting for principles of energy generation. By interpreting 'energy circle' and principles of energy generation, and applying it to the site, the design met the various desires of the KOSEP. This design consists of seven theme spaces; the future energy plaza, the wind plaza, the light plaza, the thermal power plaza, a water strider dam, a ecological pond and the stratum plaza. These theme spaces are consecutively placed along the circular path which surrounds the public information building and to represent how power plants generate energy in each space and diverse design techniques and special effects are used.

Energy Saving Effect for High Bed Strawberry Using a Crown Heating System (고설 딸기 관부 난방시스템의 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kwon, Jin Kyung;Kang, Youn Koo;Lee, Jae Han;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.420-428
    • /
    • 2019
  • This study is the heating energy saving test of the high-bed strawberry crown heating system. The system consists of electric hot water boiler, thermal storage tank, circulation pump, crown heating pipe(white low density polyethylene, diameter 16mm) and a temperature control panel. For crown heating, the hot water pipe was installed as close as possible to the crown part after planting the seedlings and the pipe position was fixed with a horticultural fixing pin. In the local heating type, hot water at $20{\sim}23^{\circ}C$ is stored in the themal tank by using an electric hot water boiler, and crown spot is partially heated at the setting temperature of $13{\sim}15^{\circ}C$ by turning on/off the circulation pump using a temperature sensor for controlling the hot water circulation pump which was installed at the very close to crown of strawberry. The treatment of test zone consisted of space heating $4^{\circ}C$ + crown heating(treatment 1), space heating $8^{\circ}C$(control), space heating $6^{\circ}C$ + crown heating(treatment 2). And strawberries were planted in the number of 980 for each treatment. The heating energy consumption was compared between November 8, 2017 and March 30, 2018. Accumulated power consumption is converted to integrated kerosene consumption. The converted kerosene consumption is 1,320L(100%) for space $8^{\circ}C$ heating, 928L(70.3%) for space $4^{\circ}C$ + crown heating, 1,161L($88^{\circ}C$) for space $6^{\circ}C$ + crown heating). It was analyzed that space $4^{\circ}C$ + pipe heating and space $6^{\circ}C$ + crown heating save heating energy of 29.7% and 12% respectively compared to $8^{\circ}C$ space heating(control).

Onset time comparison of solar proton event with coronal mass ejection, metric type II radio burst, and flare

  • Cho, Kyung-Suk;Hwang, Jung-A;Bong, Su-Chan;Marubashi, Katsuhide;Rho, Su-Lyun;Park, Young-Deuk
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.38.3-39
    • /
    • 2010
  • While major solar proton events (SPEs) come from the coronal mass eject (CME)-driven shocks in solar wind, there are many evidences that potentiality of CMEs to generate SPEs depends on its early evolution near the Sun and on different solar activities observed around the CME liftoff time. To decipher origin of SPE release, we have investigated onset time comparison of the SPE with CME, metric type II radio burst, and hard X-ray flare. For this, we select 30 SPEs observed from 1997 to 2006 by using the particle instrument ERNE onboard SOHO, which allows proton flux anisotropy measurement in the energy range ~10 - 50MeV. Onset time of the SPEs is inferred by considering the energy-dependent proton transport time. As results, we found that (1) SPE onset time is comparable to that of type II but later than type III onset time and HXR start time, (2) SPE onset time is mostly later than the peak time of HXR flare, (3) almost half of the SPE onsets occurred after the HXR emission, and (4) there are two groups of CME height at the onset time of SPE; one is the height below 5 Rs (low corona) and the other is above 5Rs (high corona). In this talk, we will present the onset time comparison and discuss about the origin of the SPE onset.

  • PDF