• Title/Summary/Keyword: energy monitoring module

Search Result 104, Processing Time 0.034 seconds

Performance Monitoring Study of Unglazed Transpired Solar Air Heating Module (무창 기공형 태양열 공기 난방 모듈 성능 모니터링 연구)

  • Kang, Eun-Chul;Hyun, Myung-Taek;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.67-72
    • /
    • 2002
  • Solar Air Systems (SAS) have unique advantages for space heating and tempering ventilation air. Air, unlike water, needs no protection against freezing nor are leaks damaging to the building structure or its contents. In contrast to glazed collector, unglazed steel solar collector may have higher efficiencies over glazed flat collector due to the absence of the glass. Therefore, the monitoring of SAS is so important to evaluate actual performance of SAS for right applications. This study is to provide a testing method with a movable test cell developed in KIER to evaluate the thermal performance of SAS based on international standard method ASHRAE 93-86, "Method of Testing to Determine the Thermal Performance of Solar Collectors". The monitoring tool used advanced technique LabVIEW 6i with portable notebook computer. Sample results have been obtained to access the performance of a reference and a target SAS module. The process and tool introduced here could be used to provide a performance verification data for future implementation study applications.

A Mobile Robot for Nuclear Power Plant Applications

  • Kim, Chang-Hoi;Seo, Yong-Chil;Cho, Jai-Wan;Choi, Young-Soo;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.803-807
    • /
    • 2003
  • Tele-operation and remote monitoring techniques are essential and important technologies for performing the inspection and repair tasks effectively in nuclear power plants. This paper presents the application of a mobile robot for the remote monitoring and inspection of the Calandria faces, where human access is limited because of the high-level radioactive environments during full power operation. The mobile robot was designed with reconfigurable crawler type of wheels attached on the front and rear side in order to pass through the ditch. The extendable mast, mounted on the mobile robot, can be extended up to 8 m vertically. This robot was also equipped a visible CCD/thermal infrared inspection head module and a stereo camera module for the enhancement of visual inspection.

  • PDF

A Study on the Method of Energy Saving in a Marine Cooling System (선박 냉각시스템의 에너지 절감기법에 관한 연구)

  • Oh Jin-Seok;Lim Myoung-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.587-592
    • /
    • 2005
  • The ESS(Energy Saving System) is designed to have functions of controlling. monitoring for cooling system. etc. ESS consists of the I/O module, CPU module and Display module I/O module detects various ESS data on local area and treats signals via I/O interface system. The interface system receives various status data and outputs control signals. ESS is tested with dummy signal to verify proposed functions and is shown good results. For future study ESS will be tested under real condition in the ship.

Analysis of Temperature and Generation Characteristics of Semi-transparent Module (건물일체형 반투명 태양광발전모듈의 후면 유리 종류에 따른 온도 및 발전 특성 분석)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Kim, Jun-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1106-1107
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially a temperature should be considered, for it affects both electrical efficiency of a PV module and heating/cooling load in a building. It reports the effect of thermal characteristics of the PV module on generation performance. The study was performed by monitoring the temperature and experiment. The results showed that 1 degree temperature rise reduced about 0.48% of output power.

  • PDF

Analysis of Thermal and Optical Characteristic of Semi-transparent Module according to Various Types of the Backside Glass (후면 유리 종류에 따른 투과형 태양광발전모듈의 열 및 광 특성 분석)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Kim, Kyung-Su;Yu, Gwon-Jong;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.263-268
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially a temperature should be considered, for it affects both electrical efficiency of a PV module and heating/cooling load in a building. This study investigates a semitransparent PV module that is designed as finished material for windows. Therefore it needs to considerate about the optical characteristics of the transparent module. It reports the effect of thermal and optical characteristics of the PV module on generation performance. The study was performed by measuring sun spectrum and luminance through the PV modules and by monitoring the temperature and experiment. The results showed that 1 degree temperature rise reduced about 0.48% of output power.

  • PDF

Development of Cell Voltage Monitoring Module for PEMFC (연료전지 스택의 셀 전압 감시를 위한 장치 개발)

  • Jung, Jae-Wook;Kim, Tae-Hoo;Park, Hyun-Seok;Jeon, Ywun-Seok;Ku, Bon-Woong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.376-379
    • /
    • 2006
  • In this paper, stack voltage monitoring module is developed which monitor cell voltage of the fuel cell stack and transfer it to the main controller for monitoring fault and stopping drive when the trouble is happened in the fuel cell stack. Especially, the circuit, for monitoring each cell voltage of several hundreds cells in stack, is designed and analyzed. The connector is also developed for making wire harness simple and low cost because wire harness is complicated when the cells are connect each monitoring circuit.

  • PDF

Design of an Intelligent Streetlight System in USN

  • Oh, Sun Jin
    • International Journal of Advanced Culture Technology
    • /
    • v.2 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, we propose an intelligent streetlight system that has a complex sensor module of temperature, humidity, luminance and motion detection and controlled by the fuzzy logic based central monitoring system in order to get flexible and precise manipulation of the streetlight system in USN environment. The proposed streetlight system provides low power consumption and high efficiency by using sensed data from the complex sensor module, which were collected, processed, and analyzed by the fuzzy logic based central monitoring system. The performance of the proposed streetlight system is to be evaluated by a simulation study in terms of power savings and safety at the fields constructed as a test-bed under several suggested scenarios. Finally, we know that the proposed intelligent streetlight system can maximize the energy savings efficiently with the fuzzy logic based central monitoring system and selective remote dimming control by connecting it to the wireless ubiquitous sensor network (USN) using a Zigbee module.

Development of Remote Control and Monitoring System for HID Street-lamp Based on Low Cost Zigbee Communication Network (저 가격형 Zigbee 통신 네트워크 기반 HID 가로등의 원격 제어 및 감시 시스템 개발)

  • Chung, Wan-Sup;Kim, Yang-Bae;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.69-73
    • /
    • 2014
  • In this paper, remote control and surveillance monitoring system of HID street-lamp using low-cost type of Zigbee communication module was developed. A plurality of capacitors with different capacity are attached to magnetic ballast for HID lamps. Changes in the amount of illumination can be adjusted by the changes in capacity so that the electric energy can be reduced. In Zigbee communication module, a ATmega128L microprocessor is used and in main CPU, ARM9 Core is used to construct a low-cost smart system. In surveillance monitoring systems, the system was configured to remote monitoring of presence of error in the lamp abnormalities, the status of leakage current and abnormalities of ballasts and capacitors and the validity of the proposed empirical experiment was confirmed.

Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module (전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링)

  • Jung, Deug-Il;Son, Young-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF

DTS-based Temperature Monitoring and Analysis of Battery Cell Deterioration Characteristics by Temperature Condition (DTS 기반 온도 감시 및 온도 조건에서의 배터리 셀 열화 특성 분석)

  • SoonJong, Kwon;Soo-Yeon, Kim;Jin, Hwang;Sang-Kyun, Woo;Bong-Suck, Kim
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.143-149
    • /
    • 2022
  • As ESS safety issues increase recently, there is a need to more precisely monitor the temperature of the ESS. In this paper, DTS technology for temperature monitoring of ESS batteries is introduced and the temperature measurement principle is explained. The temperature of the battery module is measured using the DTS system, and the thermal deviation between battery cells inside the battery module is analyzed. In order to analyze how thermal imbalance affects the charging and discharging performance of the battery, an accelerated degradation test was conducted. Cycle life characteristics analysis, battery surface temperature change, and AC impedance characteristics were conducted to analyze how the performance of battery cells differs according to temperature conditions.