• 제목/요약/키워드: energy monitoring module

검색결과 104건 처리시간 0.026초

Soil resistance estimation using smart instrumented dynamic penetrometers

  • Geunwoo Park;Namsun Kim;Yong-Hoon Byun;Sang Yeob Kim;Jong-Sub Lee
    • Smart Structures and Systems
    • /
    • 제34권1호
    • /
    • pp.63-72
    • /
    • 2024
  • In-situ penetration tests using dynamic penetrometers are widely used for estimating soil resistance. Additionally, these dynamic penetrometers have been instrumented to improve tests accuracy. This paper introduces smart instrumented dynamic penetrometers and discusses experimental studies for various cases. An energy monitoring module was developed to enhance the dynamic penetration tests. The standard penetration test (SPT) and instrumented dynamic cone penetrometer (IDCP) tests were conducted using the energy monitoring module. Dynamic responses obtained by the energy monitoring module were used to calculate the transferred energies into the rod head and tip to correct the evaluation of ground strength. In addition, a crosshole-type dynamic penetrometer (CDP) was developed to measure the penetration index and shear wave velocity simultaneously to estimate the strength and stiffness of ground. The results of this study indicate that smart instrumented dynamic penetrometers may be effectively used to characterize the strength and stiffness of ground.

태양전지 모듈 고장진단센서를 이용한 모니터링 시스템 (The Monitoring System of Photovoltaic Module using Fault Diagnosis Sensor)

  • 박유나;강기환;주영철;김수현;고석환;장길수
    • 한국태양에너지학회 논문집
    • /
    • 제36권5호
    • /
    • pp.91-100
    • /
    • 2016
  • This paper proposes the PV module fault diagnosis sensor which is applied to Zigbee wireless network, and monitoring system using the developed sensor. It is designed with embedded sensor in junction box. The diagnosis elements for algorithm were voltage and temperature. For that reason, It is able to reduce the price and separate the fault of bypass diode from shading differently from other monitoring systems. This fault diagnosis algorithm verified through the Field-installed operations of PV module.

태양전지모듈 고장 진단 알고리즘을 적용한 모니터링시스템 (The Monitoring System with PV Module-level Fault Diagnosis Algorithm)

  • 고석환;소정훈;황혜미;주영철;송형준;신우균;강기환;최정내;강인철
    • 한국태양에너지학회 논문집
    • /
    • 제38권3호
    • /
    • pp.21-28
    • /
    • 2018
  • The objects of PV (Photovoltaic) monitoring system is to reduce the loss of system and operation and maintenance costs. In case of PV plants with configured of centralized inverter type, only 1 PV module might be caused a large loss in the PV plant. For this reason, the monitoring technology of PV module-level that find out the location of the fault module and reduce the system losses is interested. In this paper, a fault diagnosis algorithm are proposed using thermal and electrical characteristics of PV modules under failure. In addition, the monitoring system applied with proposed algorithm was constructed. The wireless sensor using LoRa chip was designed to be able to connect with IoT device in the future. The characteristics of PV module by shading is not failure but it is treated as a temporary failure. In the monitoring system, it is possible to diagnose whether or not failure of bypass diode inside the junction box. The fault diagnosis algorithm are developed on considering a situation such as communication error of wireless sensor and empirical performance evaluation are currently conducting.

태양광 모듈 개별 모니터링을 위한 무선 IoT센서 (Development of Wireless IoT Sensors for Individual Photovoltaic Module Monitoring)

  • 박종성;김창헌;이지원;김지현;유상혁;양범승
    • Current Photovoltaic Research
    • /
    • 제9권3호
    • /
    • pp.106-109
    • /
    • 2021
  • In order to perform photovoltaic (PV) operation and management (O&M) efficiently, individual PV module monitoring is becoming more important. In this research, we developed wireless IoT sensor which can monitor individual photovoltaic modules. This IoT sensor can detect the output voltage, current and module temperature of individual modules and provide monitored data by wireless communication. Measured voltage error was 1.23%, and it shows 16.6 dBM, 0.42sec and 7.1 mA for voltage, transmittance output, response time and mean power consumption, respectively. IoT sensors were demonstrated in the test field with real climate environment condition and each of 5 sensors showed precise results of voltage, current and temperature. Also, sensors were compared with commercial power-optimizers and showed result difference within 5%.

제주지역 풍력발전량 실시간 감시 시스템 구축에 관한 연구 (A Study on the Real-Time Monitoring System of Wind Power in Jeju)

  • 김경보;양경부;박윤호;문창은;박정근;허종철
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.25-32
    • /
    • 2010
  • A real-time monitoring system was developed for transfer, receive, backup and analysis of wind power data at three wind farm(Hang won, Hankyung and Sung san) in Jeju. For this monitoring system a communication system analysis, a collection of data and transmission module development, data base construction and data analysis and management module was developed, respectively. These modules deal with mechanical, electrical and environmental problem. Especially, time series graphic is supported by the data analysis and management module automatically. The time series graphic make easier to raw data analysis. Also, the real-time monitoring system is connected with wind power forecasting system through internet web for data transfer to wind power forecasting system's data base.

기후데이터 분석을 통한 태양광모듈의 내구성 평가 기준 제안 (Suggestion of PV Module Test Methods Based on Weathering Monitoring)

  • 김경수;윤재호
    • Current Photovoltaic Research
    • /
    • 제7권2호
    • /
    • pp.46-50
    • /
    • 2019
  • The photovoltaic (PV) system consists of solar cells, solar modules, inverters and peripherals. The related evaluation and certification are proceeding as standards published by the IEC (International Electrotechnical Commission) TC (Technical Committee) 82. In particular, PV module is a component that requires stable durability over 20 years, and evaluation in various external environments is very important. Currently, IEC 61215-based standards are being tested, but temperature, humidity, wind and solar radiation conditions are not considered in all areas. For this reason, various types of defects may occur depending on the installation area of the same photovoltaic module. In particular, the domestic climate (South Korea) is moderate. The various test methods proposed by IEC 61215 are appropriate, excessive, or insufficient, depending on environmental condition. In this paper, we analyze the climate data collection for one year to understand the vulnerability of this test method of PV modules. Through this, we propose a test method for PV module suitable for domestic climatic conditions and also propose a technical consideration for installation and design of PV system.

해상공사로 인한 연안환경 모니터링시스템 (Monitoring System of Coastal Environment Changes due to the Construction on the Sea)

  • 정태성;김성곤
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제8권2호
    • /
    • pp.53-59
    • /
    • 2005
  • 연안환경요소를 효과적으로 모니터링하기 위하여 모델링 결과와 관측결과를 통합하여 제공하는 연안환경정보 제공 시스템이 개발되었다. 개발된 시스템은 실시간 관측 자료를 관리하기 위한 모니터링 모듈, 환경요소를 수치모의할 수 있는 모델링 모듈, 그리고 모니터링과 모델링된 결과를 그래픽으로 볼 수 있는 후처리 모듈로 구성되어 있다. 시스템 개발의 목적은 사용자가 쉽고, 편리하게 연안 환경요소에 대한 정보를 관찰할 수 있도록 하기 위한 것이다. 개발된 시스템을 활용하면, 연안환경요소에 대한 신속한 평가, 빠른 모니터링이 가능하여, 궁극적으로 환경오염과 자연재해로 인한 피해를 최소화할 수 있을 것이다.

  • PDF

IGCC 온라인 성능계산 모듈 (On-line Performance Calculation Module of IGCC Power Plant)

  • 주용진;김시문;이민철;정재화
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.364-367
    • /
    • 2008
  • This present paper describes concepts of the real-time operation monitoring system as a tool for enhancing the reliability and raising the availability of the first Korea IGCC (Integrated Gasification Combined Cycle) power plant. This system consists of five (5) modules : (1) Data Validation Module, (2) Performance Calculation Module (3) Performance Diagnostic Module, (4) Trip Information Module, and (5) Statistics Analysis Module. Among these modules, Performance Calculation Module is explained in more detail. The objective of this module is to continuously evaluate the degradation (decrease in performance) of the IGCC plant and its equipment in order to provide plant operators additional information to help them identify problems, improve performance.

  • PDF

전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발 (An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line)

  • 김동완;박지호;박성원
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

콘크리트 구조물에서의 열전모듈 거동에 관한 기초연구 (Fundamental Study of the Behavior of Thermoelectric Module on Concrete Structure)

  • 임치수;이재준
    • 한국도로학회논문집
    • /
    • 제17권5호
    • /
    • pp.33-38
    • /
    • 2015
  • PURPOSES : The purpose of this paper is to investigate the application of thermoelectric technology to concrete structures for harvesting solar energy that would otherwise be wasted. In various fields of research, thermoelectric technology using a thermoelectric module is being investigated for utilizing solar energy. METHODS: In our experiment, a halogen lamp was used to produce heat energy instead of the solar heat. A data logger was used to record the generated voltage over time from the thermoelectric module mounted on a concrete specimen. In order to increase the efficiency of energy harvesting, various factors such as color, architecture, and the ability to prevent heat absorption by the concrete surface were investigated for the placement of the thermoelectric module. RESULTS : The thermoelectric module produced a voltage using the temperature difference between the lower and upper sides of the module. When the concrete specimen was coated with an aluminum foil, a high electric power was measured. In addition, for the power generated at low temperatures, it was confirmed that the voltage was generated steadily. CONCLUSIONS: Thermoelectric technology for energy harvesting can be applied to concrete structures for generating electric power. The generated electricity can be used to power sensors used in structure monitoring in the future.