• Title/Summary/Keyword: energy index

Search Result 2,329, Processing Time 0.028 seconds

Improvement of Open BIM-based Building Permission Process Using EPI(Energy Performance Index) (에너지성능지표(EPI)를 대상으로 한 개방형BIM기반 건축인허가 개선방향 제시)

  • Kim, Inhan;Kim, Minchan;Choi, Jungsik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.6
    • /
    • pp.124-135
    • /
    • 2015
  • As many countries have been raising awareness of environmental issues, greater efforts for eco-friendly construction have been made in both governmental and private sectors. However, assessment circumstances for building energy performance and green building standard of legislation are still based on two dimension and handwork. This takes time, cost and labor, and makes assessment inaccurate and inefficient. Therefore, this study suggests methods to improve eco-friendly construction permission process and to automatize open BIM-based assessment of Energy Performance Index (EPI) among several eco-friendly construction certification standards. First, it analyzes the relations between assessment criteria and IFC data, and provides solutions to problems and limitations. Second, it applies the solutions to assessment program in order to automatize open BIM-based assessment for EPI. The eco-friendly construction permission process with these solutions applied will reduce time, cost, and labor by simplifying and automatizing the tasks. Also, the simplified process of design revision will improve not only productivity and efficiency but also accuracy and reliability.

Associating Factors on Energy Drinks Intake of Some Middle School Students in Incheon Area (인천지역 일부 중학생의 에너지 음료의 섭취 관련 영향요인)

  • Oh, Ji-Won;Jang, Jae-Seon
    • The Korean Journal of Food And Nutrition
    • /
    • v.30 no.3
    • /
    • pp.618-626
    • /
    • 2017
  • The purpose of this study was to investigate the intake of energy drinks and awareness of caffeine among middle school students. The subject was 313 middle school in Incheon area. The questionnaire respondents are consisted of 133 male students and 180 female students. The recognition result that allowed multiple responses to energy drink types was recognized by hot six at 28.9%, followed by red bull 24.3%, monster energy 13.8%, wolf energy 8.0% and taurine soda 6.9%, respectively. There was a significant difference in the experience of energy drink intake, intake reason, intake time and place (p<0.05), but there was no significant difference in intake frequency and place (p>0.05). There were significant differences in experience and frequency of energy drink intake (p<0.05), but there was no significant difference in intake reason, choice criteria, intake time and place (p>0.05). The result of the perception of energy drinks according to gender was 2.25 points for male students and 2.61 points for female students in the question 'caffeine is also present in tea, green tea, cola and chocolate'. There was a significant difference between male and female students (p<0.05). As a result of the recogniton of energy drinks, "the appropriate amount of caffeine is cleared and the concentration improves." When asked, "low body weight is 2.24 points, normal 2.27 points, overweight 1.89 points, obesity 2.46 points (p<0.05). There was a statistically significant difference in body mass index (BMI) between the two groups (1.95 for low body weight, 2.10 for normal body weight, 1.62 for overweight and 2.43 for obesity). Regression analysis showed that $R^2=0.007$ and F=2.798, respectively. Significant differences were found at the significance level of p<0.05. Energy drink consumption expenditure(${\beta}=0.121$, p<0.05), sleep time(${\beta}=0.130$, p<0.05), and caffeine perception(${\beta}=-0.162$, p<0.05) were significant determinants of energy drinks intake.

The rock fragmentation mechanism and plastic energy dissipation analysis of rock indentation

  • Zhu, Xiaohua;Liu, Weiji
    • Geomechanics and Engineering
    • /
    • v.16 no.2
    • /
    • pp.195-204
    • /
    • 2018
  • Based on theories of rock mechanics, rock fragmentation, mechanics of elasto-plasticity, and energy dissipation etc., a method is presented for evaluating the rock fragmentation efficiency by using plastic energy dissipation ratio as an index. Using the presented method, the fragmentation efficiency of rocks with different strengths (corresponding to soft, intermediately hard and hard ones) under indentation is analyzed and compared. The theoretical and numerical simulation analyses are then combined with experimental results to systematically reveal the fragmentation mechanism of rocks under indentation of indenter. The results indicate that the fragmentation efficiency of rocks is higher when the plastic energy dissipation ratio is lower, and hence the drilling efficiency is higher. For the rocks with higher hardness and brittleness, the plastic energy dissipation ratio of the rocks at crush is lower. For rocks with lower hardness and brittleness (such as sandstone), most of the work done by the indenter to the rocks is transferred to the elastic and plastic energy of the rocks. However, most of such work is transferred to the elastic energy when the hardness and the brittleness of the rocks are higher. The plastic deformation is small and little energy is dissipated for brittle crush, and the elastic energy is mainly transferred to the kinetic energy of the rock fragment. The plastic energy ratio is proved to produce more accurate assessment on the fragmentation efficiency of rocks, and the presented method can provide a theoretical basis for the optimization of drill bit and selection of well drilling as well as for the selection of the rock fragmentation ways.

Energy Content of Quercus mongolica Stands in Korea with Respect to Latitude and Altitude (위도와 해발고에 따른 신갈나무림의 에너지 고정량)

  • Kwon, Ki-Cheol;Lee, Don Koo
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.3
    • /
    • pp.299-308
    • /
    • 2006
  • This study was conducted to investigate differences in energy content of Quercus mongolica stands in the Republic of Korea with respect to latitude and altitude. Study sites were located in Mt. Joongwang, Pyeongchang-gun, Gangwon-do (altitude 1,300 m, 1,000 m, 800 m), Mt. Taehwa, Gwangju-gun, Gyeonggi-do (altitude 350 m), Mt. Wolak, Jecheon-si, Chungcheongbuk-do (altitude 300 m), Mt. Baekwoon, Gwangyang-gun, Jeollanam-do (altitude 800 m), and Mt. Halla, Jeju-do (altitude 1,000 m) by northern and southern aspect. Total energy content and annual energy fixation of Q. mongolica stands were 2,916-6,550 GJ/ha and 250-440 GJ/ha, respectively during the study period, Lower latitude (NE) stands of Q. mongolica showed more energy contents and annual energy fixation than higher latitude stands. Energy content and annual energy fixation of Q. mongolica stands were increased in low altitude. Energy content of Q. mongolica stands were higher in northern aspect than southern aspect. However, there were no significant differences in annual energy fixation between the aspects. Annual energy fixation of Q. mongolica stands was highly correlated with warm index and followed by descending orders: altitude, stand age, aspect, annual solar radiation and latitude.

Fuel Mix of Electricity Generating System Considering Energy Security and Climate Change Mitigations : Focusing on Complementarity between Policy Objectives (에너지 안보 및 기후변화 대책을 고려한 발전구성비의 도출 : 정책 목표간의 상호보완성을 중심으로)

  • Ryu, Hanee;Kim, Kyunam;Kim, Yeonbae
    • Environmental and Resource Economics Review
    • /
    • v.20 no.4
    • /
    • pp.761-796
    • /
    • 2011
  • The purpose of this paper is to derive fuel mix of electricity generating system with the lowest cost considering energy security and climate change mitigations as the target of energy policy. Energy Security Price Index(ESPI), based on the measure of market concentration in fossil fuel market and political risk of exporting countries, is chosen to assess the level of energy security. The methodology of Energy Conservation Supply Curve(CSC) is applied to fuel mix to meet the carbon emission mitigation through increasing the alternatives participation and introduction of new technologies. These also represent an improvement on the level of energy security, having the complementarity between two objectives. The alternative measure for improving energy security is exploration and production(E&P) of fossil fuel for energy sufficiency. Fuel mix of electricity generating system to achieve certain objectives in 2020 can be derived with the lowest cost considering energy security and carbon emission mitigations.

  • PDF

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

Evaluation of the Interruption Cost of Distribution Power Systems Considering the Failure Source and the Composite Customer Interruption Cost

  • Park, Sang-Bong;Nam, Kee-Young;Kim, Dae-Kyeong;Jeong, Seong-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.3
    • /
    • pp.124-129
    • /
    • 2003
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using composite interruption cost. This paper presents algorithms to evaluate the interruption cost of distribution power systems by taking into consideration the failure source and the composite customer interruption cost. From the consumer's standpoint, the composite customer interruption cost is considered as the most valuable index to estimate the reliability of a power distribution system. This paper presents new algorithms that take into account the load by customer type and failure probability by distribution facilities while calculating the amount of unserved energy by customer type. Finally, evaluation results of unserved energy and system interruption cost based on composite customer interruption cost are shown in detail.

Low-Resolution Wind Mapping For Estimation of Wind Resource Potential (풍력자원 잠재량 산출을 위한 저해상도 바람지도 구축)

  • Kim, Hyun-Goo;Jang, Moon-Seok;Kyong, Nam-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.307-308
    • /
    • 2006
  • The national goal of wind energy dissemination has to be determined rationally based on technically available wind resource potential. For a reliable and scientific estimation or wind resource potential, a wind map is requisite. This paper presents the national wind map of Korea established by numerical wind simulation. Prediction accuracy of the low-resolution wind map is Improved by nudging QuikSCAT data and is validated by comparing with marine buoy beacon and met-mast measurements. Therefore, quantification of national wind resource potential is now possible and is anticipating to be utilized as a core index for policy and strategy building of wind energy dissemination and technology development.

  • PDF

A Study on the Factors Affecting Bone Mineral Density in Adult Women - Based on the Mothers of Elementary School Students- (일부 초등학생의 어머니를 대상으로 한 성인 여성의 골밀도에 영향을 미치는 요인에 관한 연구)

  • 김기랑
    • Journal of Nutrition and Health
    • /
    • v.33 no.3
    • /
    • pp.241-249
    • /
    • 2000
  • The bone mineral density(vertebrae Ll-4, femoral neck, Ward's triangle and trochanter) of 160 healthy adult women aged 29-45 was measured and general characteristics, anthropomentric measurements, and dietary intake were also studied to determine the main factors affecting the bone mineral density(BMD) of adult women. The nutrient intake of the subjects was adequate to RDA level except energy, Ca, Fe, and vit A. The BMD of vertebrae L24 showed significant positive association with nutrient intake such as animal protein, P, Ca(animal) and Fe(animal). The BMD of the femoral neck correlated significantly with anthropometric measurements such as height, weight, waist circumference, hip circumference, body fat and body mass index. The BMD of both sites(vertebrae L24 and femoral neck) were significantly related to vertebrae L24 was daily Ca intake and that of femoral neck was daily energy expenditure. In conclusion, adequate nutrient intake, especially protein, P, Ca and Fe as well as increases in physical activity were suggested to prevent the loss of bone mineral density in adult women.

  • PDF

A Study on the Evaluation of Automatic Steering System of Ships in Folowing Seas (추사파중을 항행하는 선박의 자동조타 시스템 평가에 관한 연구)

  • 이경우;손경호
    • Journal of the Korean Institute of Navigation
    • /
    • v.25 no.4
    • /
    • pp.407-415
    • /
    • 2001
  • In the present study, irregular disturbances to ship dynamics is proposed, where irregular disturbances implying irregular wave and the fluctuating component of wind for the evaluation of automatic steering system of ship in following seas. Prediction method based on the principle of linear superposition. Irregular wave disturbances in following seas is calculated by frequency variation method. The mathematical model of each element of an automatic steering system is derived, which takes account of a few non-linear mechanisms. PD(Proportional-Derivative) controller and low-pass filter with a weather adjustment are adopted to modelling the characteristics of an autopilot. Performance index is introduced from the viewpoint of energy saving, which derived from the concept of energy loss on ship propulsion. Finally, the present methods are applied to two typical types of ship ; an ore carrier and a fishing boat. The various effects of control constants of autopilot on propulsive energy loss are investigated

  • PDF