• Title/Summary/Keyword: emission test

Search Result 1,624, Processing Time 0.024 seconds

Polarized Infrared Emission from Polycyclic Aromatic Hydrocarbons and Implications

  • Hoang, Thiem
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.81.2-81.2
    • /
    • 2017
  • Polarized mid-infrared emission from polycyclic aromatic hydrocarbons (PAHs) can provide a crucial test of basic physics of alignment of nanoparticles and opens a potential new window into studying magnetic fields. In this talk, I will present a new model of polarized PAH emission that takes into account the effect of PAH alignment with the magnetic field due to resonance paramagnetic relaxation. I will then present our predictions for the polarization level of the strong PAH emission features from the interstellar medium. I will present the first detection of polarization of PAH emission at 11.3micron which is consistent with our theoretical prediction. Finally, I will discuss important implications of this work for tracing magnetic fields via mid-IR PAH features and for constraining the polarization of anomalous microwave emission that is useful for the quest of CMB B-modes.

  • PDF

Study on Vacuum Packaging of Field Emission Display (Field Emission Display의 고진공 실장에 관한 연구)

  • Lee, Duck-Jung;Ju, Byeong-Kwon;Jang, Jin;Oh, Myong-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.103-106
    • /
    • 1999
  • In this paper, we suggest the FED packaging technology that have 4mm thickness, using sodalime glass-to-sodalime glass electrostatic bonding. It based on conventional silicon-glass bonding. The silicon film was deposited an around the exhausting hole on FED backside panel. And then, the silicon film of panel was successfully bonded with capping(bare) glass in vacuum environment and the FED panel was vacuum-sealed. In this method, we could achieve more 153 times increased conductance and 200 times increased vacuum efficiency than conventional tube packaging method. The vacuum level in panel, by SRG test, was maintained about low 10$_{-4}$ Torr during above two months And, the light emission was observed to 0.7-inch tubeless packaged FED. Then anode current was 34 $\mu$ A. Emission stability was constantly measured for 10 days.

  • PDF

The Development of the Life Cycle Assessment Systems for the Constraint of the Motor Vehicle Emission (자동차 배출가스 규제를 위한 전생애평가 시스템 구축)

  • 조재립;김경훈;김우식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.43
    • /
    • pp.365-379
    • /
    • 1997
  • Currently the problem of air pollution caused by the motor vehicle emission is of the most serious problems to be solved. Life Cycle Assessment is a process to evaluate the environmental burdens associated with a product or process by identifying and quantifying energy and materials used and wasters to the environment. This paper establishes a Life Cycle Assessment Systems which satisfies the criteria motor vehicle emission for the automobile producers who are currently producing the automobiles with catalytic convert. This plan also considered the constraint of the effective motor vehicle emission by way of the exhaust gas recirculation, electronic fuel injection, closed loop carburetor. In order to develope the performance of the LCA systems, the recent emissions test data have also been applied. The result of the development LCA systems has proved that the LCA plans presented in this paper satisfies the criteria motor vehicle emission and will be contributed to constrain the motor vehicle emission most effectively.

  • PDF

Calculation of CO2 Emission for Fossil-Fired Thermal Power Plant considering Coal-Oil Mix Rate (혼소율을 고려한 화력 발전소의 CO2 대기배출량 계산)

  • Lee, Sang-Joong;Kim, Soon-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.67-72
    • /
    • 2010
  • G8 summit meeting held in July 2008 decided to set up a long-term goal, by 2050, reducing the world greenhouse emissions by half of those emitted in 1990. In November 2009, the Government announced to reduce the national $CO_2$ emission by 30[%] of BAU by 2020. Electric power industries in Korea produce most of their electricity by burning fossil fuels, and emit approximately 28[%] of national $CO_2$ emissions. Monitoring the $CO_2$ emissions. Monitoring the $CO_2$ emission of electric power plants is very important. This paper presents a method to calculate the hourly $CO_2$ emission for a thermal power plant burning mixture of coal and oil using the performance test data and coal-oil mix rate. An example of $CO_2$ emission calculation is also demonstrated.

Data Qualification of Optical Emission Spectroscopy Spectra in Resist/Nitride/Oxide Etch: Coupon vs. Whole Wafer Etching

  • Kang, Dong-Hyun;Pak, Soo-Kyung;Park, George O.;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.433-433
    • /
    • 2012
  • As the requirement in patterning geometry continuously shrinks down, the termination of etch process at the exact time became crucial for the success in nano patterning technology. By virtue of real-time optical emission spectroscopy (OES), etch end point detection (EPD) technique continuously develops; however, it also faced with difficulty in low open ratio etching, typically in self aligned contact (SAC) and one cylinder contact (OCS), because of very small amount of optical emission from by-product gas species in the bulk plasma glow discharge. In developing etching process, one may observe that coupon test is being performed. It consumes costs and time for preparing the patterned sample wafers every test in priority, so the coupon wafer test instead of the whole patterned wafer is beneficial for testing and developing etch process condition. We also can observe that etch open area is varied with the number of coupons on a dummy wafer. However, this can be a misleading in OES study. If the coupon wafer test are monitored using OES, we can conjecture the endpoint by experienced method, but considering by data, the materials for residual area by being etched open area are needed to consider. In this research, we compare and analysis the OES data for coupon wafer test results for monitoring about the conditions that the areas except the patterns on the coupon wafers for real-time process monitoring. In this research, we compared two cases, first one is etching the coupon wafers attached on the carrier wafer that is covered by the photoresist, and other case is etching the coupon wafers on the chuck. For comparing the emission intensity, we chose the four chemical species (SiF2, N2, CO, CN), and for comparing the etched profile, measured by scanning electron microscope (SEM). In addition, we adopted the Dynamic Time Warping (DTW) algorithm for analyzing the chose OES data patterns, and analysis the covariance and coefficient for statistical method. After the result, coupon wafers are over-etched for without carrier wafer groups, while with carrier wafer groups are under-etched. And the CN emission intensity has significant difference compare with OES raw data. Based on these results, it necessary to reasonable analysis of the OES data to adopt the pre-data processing and algorithms, and the result will influence the reliability for relation of coupon wafer test and whole wafer test.

  • PDF

Development of NH3 Emission Factors using a Dynamic Flux Chamber in a Sewage Treatment Plant (부유형 챔버를 이용한 하수처리장에서의 암모니아 배출 특성 연구)

  • Jeon, Eui-Chan;Sa, Jae-Hwan;Park, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.263-273
    • /
    • 2005
  • In this study, the major emission procedures and emission characteristics were identified at the site of sewage treatment plant which is one of the major sources of ammonia. At the same time the emission factors and emission rates were estimated. In order to calculate the emission flux, we used a Dynamic Flux Chamber(DFC), which is found to be a proper sampling devise for area sources such as sewage treatment plant. It was found that the most stable sampling condition was when the stirrer's speed of DFC was 120RPM, and it would be the best time to take a sample 60 minutes later after setting the chamber. The relatively higher flux was shown in Autumn compared to summer and winter. Annual ammonia emission rates procedures were calculated as $906.32{\mu}g/activity-ton$, $1,114.72{\mu}g/activity-ton$ and $437.53{\mu}g/activity-ton$ each at the primary settling basin, aeration basin and the final settling basin, respectively. The ammonia emission rate the highest at in the aeration basin according to this test. This results was due to that the surface of aeration basin or the final settling basin is relatively wider than the primary settling basin.

Medical Clinics' quality Management of X-ray Units in Gyeongbuk Area (경북 지역 의원급의 X선 발생장치 정도관리 실태)

  • Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.267-275
    • /
    • 2010
  • Quality management of an x-ray unit drastically differs according to the type of establishment of medical institutions. Many primary medical institutions have it, but they do not pay much attention to quality management. In the study, Gyeongbuk area has been divided into four zones from January 4, 2010 to September 3, 2010, and four places were designated by city. Among medical institutions located at a total of 16 sites, the target was 8 places with X-ray emission equipment 10 years or more in use as well as 8 places with X-ray emission equipment less than 10 years in use. The 5 essential items of quality control were tested. In the test that checked for equipment it was found that sites with X-ray emission equipment 10 years or more in use didn't have ground connection (6.25%) while all of them passed the current leak test. In the exposure dose reproducibility test 4 sites with X-ray emission equipment 10 years or more in use (25%) and 1 site with X-ray emission equipment less than 10 years in use didn't pass the test. In the KVp accuracy test 5 sites with X-ray emission equipment 10 years or more in use (31.25%) and 2 sites with X-ray emission equipment less than 10 years in use (12.5%) didn't pass the test. In the tube current and tube current amount test 3 sites with X-ray emission equipment 10 years or more in use (18.75%) and 1 site with less than 10 years in use (6.25%) didn't pass the test. According to the findings of the present research, quality control at medical institutions with X-ray equipment 10 years or more in use was poorer than medical institutions with X-ray equipment less than 10 years in use. In this regard, administrative and technical measures need to be taken as soon as possible. In addition, owners of medical clinics or unit managers need to raise awareness, and it is necessary to revise a regular test cycle every year or every two years if they have old equipment or if the equipment is not used on a frequent basis. And it is also important to provide regular educational programs for quality management.

Relationship between Take-off Behavior of Hard-disk Slider and AE Signal (하드디스크 슬라이더의 부상 특성과 AE신호의 관계)

  • 이상민;문재택;김대은
    • Tribology and Lubricants
    • /
    • v.17 no.1
    • /
    • pp.40-55
    • /
    • 2001
  • Acoustic emission(AE) signal has been widely utilized to monitor the interaction at the head/disk interface. In this work the relationship between the AE signal and the state of contact between the slider and the disk is presented. Results of the FFT(Fast Fourier Transform) analyses of the AE signal could be used to better understand the interfacial interaction. Also, it was found that wear particles affect the AE signal. Therefore, the signal can be used to monitor the wear particle presence at the interface.

Relationship between Take-off Behavior of Hard-disk Slider and AE Signal (하드디스크 슬라이더의 부상 특성과 AE신호의 관계)

  • 이상민;문재택;김대은
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.310-317
    • /
    • 1999
  • Acoustic emission(AE) signal has been widely utilized to monitor the interaction at the head/disk interface. In this work the relationship between the AE signal and the state of contact between the slider and the disk is presented. Results of the FFT analyses of the AE signal could be used to better understand the interfacial interaction. Also, it was found that wear particles affect the AE signal. Therefore, the signal can be used to monitor the wear particle presence at the interface.

  • PDF

Friction welding of high speed steel to carbon steel and AE evaluation (고속도강과 탄소공구강의 마찰용접 및 AE 평가)

  • 이원석;윤인진;전태언;오세규
    • Proceedings of the KWS Conference
    • /
    • 1995.04a
    • /
    • pp.114-117
    • /
    • 1995
  • A study of friction welding of high speed steel(SKH51) bar for blade side to carbon steel(STC3) bar for shank side was carried out experimentally through tensile test, hardness lest, microstructure, and acoustic emission (AR) test. So, this paper deals with optimizing the welding conditions and the real-time quality(strength) evaluation of friction welded joints by acoustic emission technique.

  • PDF