• Title/Summary/Keyword: electron microscope

Search Result 4,378, Processing Time 0.031 seconds

Transmission Electron Microscope Specimen Preparation of Si-Based Anode Materials for Li-Ion Battery by Using Focused Ion Beam and Ultramicrotome

  • Chae, Jeong Eun;Yang, Jun Mo;Kim, Sung Soo;Park, Ju Cheol
    • Applied Microscopy
    • /
    • v.48 no.2
    • /
    • pp.49-53
    • /
    • 2018
  • A successful transmission electron microscope (TEM) analysis is closely related to the preparation of the TEM specimen and should be followed by the suitable TEM specimen preparation depending on the purpose of analysis and the subject materials. In the case of the Si-based anode material, lithium atoms of formed Li silicide were removed due to ion beam and electron beam during TEM specimen preparation and TEM observation. To overcome the problem, we proposed a new technique to make a TEM specimen without the ion beam damage. In this study, two types of test specimens from the Si-based anode material of Li-ion battery were prepared by respectively adopting the only focused ion beam (FIB) method and the new FIB-ultramicrotome method. TEM analyses of two samples were conducted to compare the Ga ion damage of the test specimen.

The Effect of Mn Content Solution-treatment Temperatures on Insoluble Phases in Al-Li-Cu-Mg-Mn-Zr Alloys (Al-Li-Cu-Mg-Zr 합금의 미고용상에 미치는 용체화 처리 및 Mn 함량의 영향)

  • Shin, Hyun-Sik;Ming, He;Cho, Kwon-Koo;Chung, Young-Hoon;Shin, Myung-Chul
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.517-526
    • /
    • 1994
  • Large insoluble phases and dispersoids in Al-Li-Cu-Mg-Mn-Zr alloys containing Mn were analyzed with EPMA(Electron Probe Microanalyzer) and SAEM(Scanning Auger Electron Microscope). Morphology, distribution and volume fraction of the large insoluble phase were also analyzed quantitatively by optical microscopy. Mechanical properties were tested at room temperature and at $200^{\circ}C$. With increasing Mn contents, the volume fraction of the large insoluble phases increased steeply, thus decreasing ductility. Mn was found to be very effective for obtaing uniformly distributed fine-grain structures. The alloy containing 0.44 wt% Mn showed the highest tensile strength among Mn-bearing alloys tested.

  • PDF

FINE STRUCTURES OF PHYSIOLOGIC AND PATHOLOGIC ROOT RESORPTION SURFACES OF DECIDUOUS TEETH (생리적 및 염증성 유치 치근 흡수면의 미세구조)

  • Park, Yoon-Hee;Sohn, Heung-Kyu;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.524-534
    • /
    • 2000
  • Deciduous teeth can be extracted for two reasons, one due to the physiologic resorption and the other by the inflammation at the apex after traumatic injury. Physiologic resorption may be different from pathologic resorption in timing and mechanism. Therefore we resumed the different features of physiologic and pathologic resorption root surfaces. Many previous studies showed micromorphology of resorbed surface of roots of deciduous teeth. But, few studies compared physiological and pathological root resorption surfaces. In this study, we carefully observed microscopic morphologies of those two different root surfaces by scanning electron microscope and histologic features by light microscope. The resultant differences between physiologic and pathologic resorption surfaces of deciduous teeth were as follows: 1. The morphology of pathologic resorption lacunae due to inflammation varied in size and shape with irregular boundaries compared with the physiologic areas from scanning electron microscope observations. 2. From light microscope observations, several large resorption fossae containing numerous resorption lacunae were found, whereas the resorption lacunae were irregular in shape with pathologic resorption surface. 3. Numerous multinucleated giant cells were closely attached to the physiologic resorption lacunae, whereas several kinds of mesenchymal cells with numerous inflammatory cells were found in the areas adjacent to the pathologic resorption surface. 4. Light microscope findings showed that compensating cementum formation took place along some of the areas of inflammatory dentinal resorption. In conclusion, several morphological differences were present between physiologic and pathologic root resorption surfaces of human deciduous teeth. The future studies should include cytochemistry to clarify the cellular roles in resorption process observations of pulpal surfaces of coronal and radicular dentin to and the changes that occur in each phase of human deciduous tooth resorption.

  • PDF

Empirical relationship between band gap and synthesis parameters of chemical vapor deposition-synthesized multiwalled carbon nanotubes

  • Obasogie, Oyema E.;Abdulkareem, Ambali S.;Mohammed, Is'haq A.;Bankole, Mercy T.;Tijani, Jimoh. O.;Abubakre, Oladiran K.
    • Carbon letters
    • /
    • v.28
    • /
    • pp.72-80
    • /
    • 2018
  • In this study, an empirical relationship between the energy band gap of multi-walled carbon nanotubes (MWCNTs) and synthesis parameters in a chemical vapor deposition (CVD) reactor using factorial design of experiment was established. A bimetallic (Fe-Ni) catalyst supported on $CaCO_3$ was synthesized via wet impregnation technique and used for MWCNT growth. The effects of synthesis parameters such as temperature, time, acetylene flow rate, and argon carrier gas flow rate on the MWCNTs energy gap, yield, and aspect ratio were investigated. The as-prepared supported bimetallic catalyst and the MWCNTs were characterized for their morphologies, microstructures, elemental composition, thermal profiles and surface areas by high-resolution scanning electron microscope, high resolution transmission electron microscope, energy dispersive X-ray spectroscopy, thermal gravimetry analysis and Brunauer-Emmett-Teller. A regression model was developed to establish the relationship between band gap energy, MWCNTs yield and aspect ratio. The results revealed that the optimum conditions to obtain high yield and quality MWCNTs of 159.9% were: temperature ($700^{\circ}C$), time (55 min), argon flow rate ($230.37mL\;min^{-1}$) and acetylene flow rate ($150mL\;min^{-1}$) respectively. The developed regression models demonstrated that the estimated values for the three response variables; energy gap, yield and aspect ratio, were 0.246 eV, 557.64 and 0.82. The regression models showed that the energy band gap, yield, and aspect ratio of the MWCNTs were largely influenced by the synthesis parameters and can be controlled in a CVD reactor.

The Effects of Natural Disinfectants Naringin on Corneal Epithelium and Endothelium of Rabbit - By Scanning Electron Microscopy (천연보존제 나린진이 가토안의 각막 상피와 내피에 미치는 영향 - 주사전자현미경을 통한 고찰)

  • Kim, In-Suk;Yoo, Geun-Chang;Chae, Soo-Chul;Jeon, Chang-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.63-69
    • /
    • 2005
  • The effects of R products of B company and natural disinfectant naringin, well-known chemical disinfectant on Corneal endothelium and epithelium of rabbit were observed by scanning electron microscope. The main component of naringin is extract of grapefruit seed, which is one of the flavonoid widely recognized as natural antioxidants and used as preservative agent of food and cosmetics. The chemical disinfectants cytotoxicity in cell cultures were announced by MIT assay and LDH leakage assay. But there has been no study about that chemical disinfectants and natural disinfectants is inserted drops on rabbit's cornea directly. In this test R products B company and natural disinfectants has been dropped on the cornea of rabbits for one weeks and observed cytotoxiciy by light camera after rose bengal staining. Also, we analysed the damage of corneal epithelium and endothelium morphologically after enucleating the cornea by scanning electron microscope.

  • PDF

Scanning Electron Microscopic Study on the Microplastics in Rinse Off Cosmetics (피부 청결 화장품에 첨가된 미세플라스틱의 주사전자현미경적 연구)

  • Kim, Kyung-Sook;Chang, Byung-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.9
    • /
    • pp.252-257
    • /
    • 2019
  • We investigated the microstructure and morphological characteristics of microplastics added to rinse off cosmetics by scanning electron microscope. The size of the microplastic was in a wide range of sizes, from $250{\mu}m$ to 1.5mm in diameter. The small microplastics were in the shape of elongated particles and the large microplastics were cuboidal. Most cubic microplastics were observed in the form of squares or rectangles. The surface of the cubic microplastic was smoothly observed without protruding portions, but irregularly many gaps were formed. The gap between openings was measured from about $5{\mu}m$ to $20{\mu}m$. It has not been confirmed that these gaps are formed from the surface of the microplastic to the inside there of.

Recent Advances in Electron Crystallography

  • Chung, Jeong Min;Lee, Sangmin;Jung, Hyun Suk
    • Applied Microscopy
    • /
    • v.47 no.3
    • /
    • pp.160-164
    • /
    • 2017
  • Electron crystallography has been used as the one of powerful tool for studying the structure of biological macromolecules at high resolution which is sufficient to provide details of intramolecular and intermolecular interactions at near-atomic level. Previously it commonly uses two-dimensional crystals that are periodic arrangement of biological molecules, however recent studies reported a novel technical approach to electron crystallography of three-dimensional crystals, called micro electron-diffraction (MicroED) which involves placing the irregular and small sized protein crystals in a transmission electron microscope to determine the atomic structure. In here, we review the advances in electron crystallography techniques with several recent studies. Furthermore, we discuss the future direction of this structural approach.

OBSERVATION OF THE MAGNETIC DOMAIN IN THIN-FILM HEADS BY ELECTRON MICROSCOPY

  • Kobayashi, Kazuo
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.710-715
    • /
    • 1995
  • Magnetic domains were observed using an image lock-in technique for backscattered electron contrast (Type II) with a 200 kV scanning electron microscope. Backscattered electrons indicate a difference in magnetic domain structures at the upper and lower parts of the upper pole in thin-film heads, changing the acceleration voltage. With this method, it is also possible to observe the domain structure of the thin-film head pole through a 10 to $20\;\mu\textrm{m}$ protective layer, and the upper shield of the MR head through the coil in the resist, alumina overcoat, and upper pole.

  • PDF

Hardware Design for the Control Signal Generation of Electron Optic by Focal Length (Focal length에 의한 전자 렌즈의 제어 신호 생성을 위한 하드웨어 설계)

  • Lim, Sun-Jong;Lee, Chan-Hong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.96-100
    • /
    • 2007
  • Condenser lens and objective lens are used to demagnify the image of the crossover to the final spot size. In lens, electrons are focused by magnetic fields. This fields is fringing field. It is important in electron focusing. Electron focusing occurs the radial component field and axial component field. Radial component produces rotational force and axial component produces radial force. Radial force causes the electron's trajectory to curve toward the optic axis and corss it. Focal length decreases as the current of lens increases. In this paper, we use the focal length for desiging the hardware of lens current control and present the results.

Characteristics of Pearlescent Pigment using in Make-up Cosmetics (색조화장에 사용되는 진주광택 안료의 특성)

  • Kwak, Han-Ah;Choi, Eun-Young;Chang, Byung-Soo
    • Applied Microscopy
    • /
    • v.39 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • We investigated the morphological characteristics of the pearlescent pigment by using scanning electron microscope, energy dispersive X-ray spectrometry and thermal analyzer. The result is that the shape of pigment is platy polygonal form through observing the pearlescent pigment by the scanning electron microscope. The size of pigment is various and not formed in standardized size or shape. The pigment flakes were measured about from $30{\mu}m$ to $300{\mu}m$. The tip of the piece of pigment is pointed shape or angled. The result of observing them by the scanning electron microscope in magnifying high power is that the edge and the lateral face of them is an round form and the measurement of thickness is about $9{\mu}m$. As well using the high magnification scanning electron microscope, the surface of the pigment flake observed like rugged as coating with the $TiO_2$ element, the diameter of the coating particle is around 60 nm, then the coating particle consists of granular substance. Analysis of the configuration elements of pearlescent pigment using by the energy dispersive X-ray spectrometry is that O, Si, C, Na, Ca, Ti, Zn detected in the surface of pigment and its lateral face identifies similar components. In thermal analysis, there are no contained quantity differences between them in beginning from $100^{\circ}C$ to $800^{\circ}C$ showing thermal analysis, 1.1% out of contained quantity reduced at $115^{\circ}C$, 1.7% dropped at $416^{\circ}C$, and 1.9% decreased at $797^{\circ}C$.