• Title/Summary/Keyword: electron beam treatment

Search Result 280, Processing Time 0.033 seconds

Granulocytic Sarcoma: Results of Radiotherapy (Granulocytic Sarcoma : 방사선 치료 성적)

  • Song Mi Hee;Chung Eun Ji;Seong Jin Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.261-266
    • /
    • 1992
  • We analyzed retrospectively the patients of granulocytic sarcoma treated with radiotherapy at the Department of Radiation Oncology, Yonsei University College of Medicine from Mar 1987 to Mar.1992 in an attempt to review our experience with irradiation of granulocytic sarcoma and to evaluate the treatment results for the radiation dose response. Fourteen lesions of granulocytic sarcoma in 9 patients were developed in variable clinical settings such as AML, CML and without leukemia. The involved lesions were bone, lymph node, soft tissue and skin in descending order of occurrence. All of the lesions in 9 patients were treated with external beam radiotherapy (Co-60 or electron beam). Both age distribution and clinical settings did not show any correlation with the response to treatment. The response to treatment seemed to be better for lesions in the bone than in other involved lesions. The majority received local irradiation of a total dose of more than 2000 cGy. Radiation dose of more than 2000 cGy showed excellent local control of $100\%$, (11/11), while local control decreased to $33\%$(1/3) with total dose less than 2000 cGy. In conclusion, local radiotherapy seems to be very effective for palliative or curative aim of granulocytic sarcoma, and a radiation dose more than 2000 cGy is highly recommended.

  • PDF

Radiation Therapy for Primary Eyelid Cancers in Tunisia

  • Belaid, A;Nasr, C;Benna, M;Cherif, A;Jmour, O;Bouguila, H;Benna, F
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3643-3646
    • /
    • 2016
  • Management of eyelid cancers is based on surgery and/or radiotherapy (RT). The treatment objective is to control tumors with acceptable functional and esthetic outcomes. The aim of this study was to evaluate the results of radiation therapy in management of epithelial eyelid cancers, reviewing retrospectively the clinical records of patients treated in our institution from January 1989 to December 2013. We focused on clinical and histological features, treatment characteristics, tolerance and disease control. One hundred and eight patients (62 men and 46 women) were enrolled, with a mean age of 61 years [ranges 15-87]. The most frequent tumor location was the inner canthus (42.6%). Median tumor size was 21 mm [ranges 4-70]. Histological type was basal cell carcinoma in 88 cases (81.5%), squamous cell carcinoma in 16 (14.8%) and sebaceous carcinoma in 4 (3.7%). Radiation therapy was exclusive in 67 cases (62%) and post-operative for positive or close margins in the remaining cases. Kilovoltage external beam radiotherapy (KVRT) was used in 63 patients (58.3%) and low-dose-rate interstitial brachytherapy in 37 (34.3%). Eight (7.4%) were treated with cobalt or with a combination of KVRT-cobalt, KVRT-electron beams, KVRT-brachytherapy or cobalt-electron beams. The total delivered radiation doses were 70 Gy (2 Gy/fraction) in 62 patients (57.4%), 66 Gy (2 Gy/fraction) in 37 (34.3%) and 61.2 Gy (3.4Gy/fraction) in 9 (8.3%). After a median follow-up of 64 months, we noted 10 cases of local recurrences(9.2%): 7 after exclusive and 3 after post-operative RT. No local recurrence occurred in patients treated with brachytherapy. Actuarial 5-year local recurrence-free rate, disease-free survival and overall survival were respectively 90%, 90% and 97%. T-stage was found to be a significant factor for recurrence (p=0.047). All acute radiation-related reactions were scored grade I or II. Delayed effects were eye watering in 24 cases (22.2%), eye dryness in 19 (17.6%), unilateral cataract in 7 (6.4%) and ectropion in 4 (3.7%). Radiation therapy and especially brachytherapy is an efficient treatment of eyelid cancers, allowing eye conservation and functional preservation with good local control rates and acceptable toxicity.

Observations on the Modulated Structure in Pyrochlore-type Compounds, $In_2(Ti_{1.7}Zn_{0.3})O_{0.67}$ and $In_2(Ti_{1.7}Mg_{0.3})O_{6.7}$ (Pyrochlore형 화합물 $In_2(Ti_{1.7}Zn_{0.3})O_{0.67}$$In_2(Ti_{1.7}Mg_{0.3})O_{6.7}$에서의 변조구조 관찰)

  • Lee, Hwack-Joo;Park, Hyun-Min;Cho, Yang-Koo;Ryu, Hyun;Nahm, Sahn;Bando, Y.
    • Applied Microscopy
    • /
    • v.29 no.4
    • /
    • pp.471-477
    • /
    • 1999
  • Microstructural observations on the pyrochlore-type $Lu_2Ti_2O_7$ and the similar type of compounds, $In_2(Ti_{1.7}Zn_{0.3})O_{6.7}$ and $In_2(Ti_{1.7}Mg_{0.3})O_{6.7}$ which were made by the isothermal heat-treatment at 1623K for 18 days in Pt tube, were carried out using a top-entry HRTEM working at 200 kV. The modulated structures were found in both compounds, however, not in $Lu_2Ti_2O_7$. From the electron diffraction pattern analysis, the modulated superlattices are incommensurate and are 2.69 times of sublattices along (220) direction. The high resolution TEM images have shown that the superlattices consist of alternate superlattices which are composed of two or three sublattices, resulting in the average of 2.7 times of sublattices in accordance with the analysis of electron diffraction patterns. The crystal structures of both compounds are found to quite similar to those of pyrochlore, however the evidence that the cubic axes are slightly deviated from right angle. The modulated structure has gradually changed to the unmodulated structure induced by electron irradiation.

  • PDF

Preparation of poly-crystalline Si absorber layer by electron beam treatment of RF sputtered amorphous silicon thin films (스퍼터링된 비정질 실리콘의 전자빔 조사를 통한 태양전지용 흡수층 제조공정 연구)

  • Jeong, Chaehwan;Na, Hyeonsik;Nam, Daecheon;Choi, Yeonjo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.81-81
    • /
    • 2010
  • 유리기판위에 큰 결정입자를 갖는 실리콘 (폴리 실리콘) 박막을 제조하는 것은 가격저가화 및 대면적화 측면 같은 산업화의 높은 잠재성을 가지고 있기 때문에 그동안 많은 관심을 가지고 연구되어 오고 있다. 다양한 방법을 이용하여 다결정 실리콘 박막을 만들기 위해 노력해 오고 있으며, 태양전지에 응용하기 위하여 연속적이면서 10um이상의 큰 입자를 갖는 다결정 실리콘 씨앗층이 필요하며, 고속증착을 위해서는 (100)의 결정성장방향 등 다양한 조건이 제시될 수 있다. 다결정 실리콘 흡수층의 품질은 고품질의 다결정 실리콘 씨앗층에서 얻어질 수 있다. 이러한 다결정 실리콘의 에피막 성장을 위해서는 유리기판의 연화점이 저압 화학기상증착법 및 아크 플라즈마 등과 같은 고온기반의 공정 적용의 어려움이 있기 때문에 제약 사항으로 항상 문제가 제기되고 있다. 이러한 관점에서 볼때 유리기판위에 에피막을 성장시키는 방법으로 많지 않은 방법들이 사용될 수 있는데 전자 공명 화학기상증착법(ECR-CVD), 이온빔 증착법(IBAD), 레이저 결정화법(LC) 및 펄스 자석 스퍼터링법 등이 에피 실리콘 성장을 위해 제안되는 대표적인 방법으로 볼 수 있다. 이중에서 효율적인 관점에서 볼때 IBAD는 산업화측면에서 좀더 많은 이점을 가지고 있으나, 박막을 형성하는 과정에서 큰 에너지 및 이온크기의 빔 사이즈 등으로 인한 표면으로의 damages가 일어날 수 있어 쉽지 않는 방법이 될 수 있다. 여기에서는 이러한 damage를 획기적으로 줄이면서 저온에서 결정화 시킬 수 있는 cold annealing법을 소개하고자 한다. 이온빔에 비해서 전자빔의 에너지와 크기는 그리드 형태의 렌즈를 통해 전체면적에 조사하는 것을 쉽게 제어할 수 있으며 이러한 전자빔의 생성은 금속 필라멘트의 열전자가 아닌 Ar플라즈마에서 전자의 분리를 통해 발생된다. 유리기판위에 흡수층 제조연구를 위해 DC 및 RF 스퍼터링법을 이용한 비정질실리콘의 박막에 대하여 두께별에 따른 밴드갭, 캐리어농도 등의 변화에 대하여 조사한다. 최적의 조건에서 비정질 실리콘을 2um이하로 증착을 한 후, 전자빔 조사를 위해 1.4~3.2keV의 다양한 에너지세기 및 조사시간을 변수로 하여 실험진행을 한 후 단면의 이미지 및 결정화 정도에 대한 관찰을 위해 SEM과 TEM을 이용하고, 라만, XRD를 이용하여 결정화 정도를 조사한다. 또한 Hall효과 측정시스템을 이용하여 캐리어농도, 이동도 등을 각 변수별로 전기적 특성변화에 대하여 분석한다. 또한, 태양전지용 흡수층으로 응용을 위하여 dark전도도 및 photo전도도를 측정하여 광감도에 대한 결과가 포함된다.

  • PDF

Effects of Increase in Ratio of Phenolic Hydroxyl Function on Carbon Fiber Surfaces by Anodic Oxidation on Mechanical Interfacial Bonding of Carbon Fibers-reinforced Epoxy Matrix Composites (양극산화 처리에 따른 탄소섬유 표면의 페놀릭 하이드록실 관능기 비율의 증가가 에폭시기지 복합재료의 기계적 계면결합 특성에 미치는 영향)

  • Kim, Dong-Kyu;Kim, Kwan-Woo;Han, Woong;Song, Bhumkeun;Oh, Sang-Yub;Bang, Yun Hyuk;Kim, Byung-Joo
    • Applied Chemistry for Engineering
    • /
    • v.27 no.5
    • /
    • pp.472-477
    • /
    • 2016
  • We studied the effects of anodic oxidation treatments of carbon fibers on interfacial adhesion of the carbon fibers-reinforced epoxy matrix composites with various current densities. The surface of treated carbon fibers was characterized by atomic force microscope (AFM), field emission-scanning electron microscope (FE-SEM), Fourier transform infrared spectroscopy (FT-IR), and X-ray photoelectron spectroscopy (XPS). The interlaminar shear strength (ILSS) of the composites was determined by a short beam shear test. This result showed that both the roughness and oxygen group of the carbon fibers surface increased in proportion to the current density. After anodic-oxidation-treated, the ILSS also increased as a function of the current density. In addition, the proportional relationship between ILSS and phenolic hydroxyl group was confirmed. The ILSS of the CF-2.0 sample increased by 4% compared to that of the CF-AS sample, because the anodic oxidation treatment increased the oxygen group and roughness on the carbon fibers surface, which leading to the improvement of the interfacial adhesion of the carbon fibers-reinforced epoxy matrix composites. Among these, the phenolic hydroxyl group which has the proportional relationship with ILSS is found to be the most important factor for improving the interfacial adhesion of the carbon fibers-reinforced epoxy matrix composites.

EFFECTS OF SURFACE ROUGHNESS AND MULTILAYER COATING ON THE CORROSION RESISTANCE OF Ti-6Al-4V ALLOY

  • Ko, Yeong-Mu;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.134-135
    • /
    • 2003
  • The dental implant materials required good mechanical properties, such as fatigue strength, combined with a high resistance to corrosion. For increasing fatigue resistance and delaying onset of stress corrosion cracking, shot peening has been used for > 50 years to extend service life of metal components. However, there is no information on the electrochemical behavior of shot peened and hydroxyapatite(HA) coated Ti-6Al-4V alloys. To increase fatigue strength, good corrosion resistance, and biocompatibility, the electrochemical characteristics of Ti/TiN/HA coated and shot peened Ti-6Al-4V alloys by electron beam physical vapor deposition(EB-PVD) have been researched by various electrochemical method in 0.9%NaCl. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. The produced materials were quenched at 1000$^{\circ}C$ under high purity dried Ar atmosphere and were hold at 500$^{\circ}C$ for 2 hrs to achieve the fatigue strength(1140㎫) of materials. Ti-6Al-4V alloys were prepared under the condition of hydrogen and vacuum arc furnace. Shot peening(SP) and sand blasting treatment was carried out for 1, 5, and 10min. On the surface of Ti-6Al-4V alloys using the steel balls of 0.5mm and alumina sand of 40$\mu\textrm{m}$ size. Ti/TiN/HA multilayer coatings were carried out by using electron-beam deposition method(EB-PVD) as shown Fig. 1. Bulk Ti, powder TiN and hydroxyapatite were used as the source of the deposition materials. Electrons were accelerated by high voltage of 4.2kV with 80 - 120mA on the deposition materials at 350$^{\circ}C$ in 2.0 X 10-6 torr vacuum. Ti/TiN/HA multilayer coated surfaces and layers were investigated by SEM and XRD. A saturated calomel electrode as a reference electrode, and high density carbon electrode as a counter electrode, were set according to ASTM GS-87. The potentials were controlled at a scan rate of 100 mV/min. by a potentiostat (EG&G Co.273A) connected to a computer system. Electrochemical tests were used to investigate the electrochemical characteristics of Ti/TiN/HA coated and shot peened materials in 0.9% NaCl solution at 36.5$^{\circ}C$. After each electrochemical measurement, the corrosion surface of each sample was investigated by SEM.

  • PDF

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF

Novel Activation by Electrochemical Potentiostatic Method

  • Lee, Hak-Hyeong;Lee, Jun-Gi;Jeong, Dong-Ryeol;Gwon, Gwang-U;Kim, Ik-Hyeon
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.29.1-29.1
    • /
    • 2009
  • Fabrication of good quality P-type GaN remained as a challenge for many years which hindered the III-V nitrides from yielding visible light emitting devices. Firstly Amano et al succeeded in obtaining P-type GaN films using Mg doping and post Low Energy Electron Beam Irradiation (LEEBI) treatment. However only few region of the P-GaN was activated by LEEBI treatment. Later Nakamura et al succeeded in producing good quality P-GaN by thermal annealing method in which the as deposited P-GaN samples were annealed in N2 ambient at temperatures above $600^{\circ}C$. The carrier concentration of N type and P-type GaN differs by one order which have a major effect in AlGaN based deep UV-LED fabrication. So increasing the P-type GaN concentration becomes necessary. In this study we have proposed a novel method of activating P-type GaN by electrochemical potentiostatic method. Hydrogen bond in the Mg-H complexes of the P-type GaN is removed by electrochemical reaction using KOH solution as an electrolyte solution. Full structure LED sample grown by MOCVD serves as anode and platinum electrode serves as cathode. Experiments are performed by varying KOH concentration, process time and applied voltage. Secondary Ion Mass Spectroscopy (SIMS) analysis is performed to determine the hydrogen concentration in the P-GaN sample activated by annealing and electrochemical method. Results suggest that the hydrogen concentration is lesser in P-GaN sample activated by electrochemical method than conventional annealing method. The output power of the LED is also enhanced for full structure samples with electrochemical activated P-GaN. Thus we propose an efficient method for P-GaN activation by electrochemical reaction. 30% improvement in light output is obtained by electrochemical activation method.

  • PDF

Dosimetric characterization and commissioning of a superficial electronic brachytherapy device for skin cancer treatment

  • Park, Han Beom;Kim, Hyun Nam;Lee, Ju Hyuk;Lee, Ik Jae;Choi, Jinhyun;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.937-943
    • /
    • 2018
  • Background: This work presents the performance of a novel electronic brachytherapy (EBT) device and radiotherapy (RT) experiments on both skin cancer cells and animals using the device. Methods and materials: The performance of the EBT device was evaluated by measuring and analyzing the dosimetric characteristics of X-rays generated from the device. The apoptosis of skin cancer cells was analyzed using B16F10 melanoma cancer cells. Animal experiments were performed using C57BL/6 mice. Results: The X-ray characteristics of the EBT device satisfied the accepted tolerance level for RT. The results of the RT experiments on the skin cancer cells show that a significant apoptosis induction occurred after irradiation with 50 kVp X-rays generated from the EBT device. Furthermore, the results of the animal RT experiments demonstrate that the superficial X-rays significantly delay the tumor growth and that the tumor growth delay induced by irradiation with low-energy X-rays was almost the same as that induced by irradiation with a high-energy electron beam. Conclusions: The developed new EBT device has almost the same therapeutic effect on the skin cancer with a conventional linear accelerator. Consequently, the EBT device can be practically used for human skin cancer treatment in the near future.

TENSILE BOND STRENGTH OF ALUNMINA CORE TREATED BY ION ASSISTED REACTION (이온보조반응법으로 처리한 알루미나 코아의 인장결합강도에 관한 연구)

  • Kim, Hyeong-Seob;Woo, Yi-Hyung;Kwon, Kung-Rock;Choi, Boo-Byung;Choi, Won-Kook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.704-723
    • /
    • 2000
  • This study was undertaken to evaluate the tensile bond strength of In-Ceram alumina core treat-ed by ion assisted reaction(IAR). Ion assisted reaction is a prospective surface modification technique without damage by a keV low energy ion beam irradiation in reactive gas environments or reactive ion itself. 120 In-Ceram specimens were fabricated according to manufacturer's directions and divided into six groups by surface treatment methods of In-Ceram alumina core. SD group(control group): sandblasting SL group: sandblasting + silane treatment SC group: sandblasting + Siloc treatment IAR I group: sandblasting + Ion assisted reaction with argon ion and oxygen gas IAR II group: sandblasting + Ion assisted reaction with oxygen ion and oxygen gas IAR III group: sandblasting + Ion assisted reaction with oxygen ion only For measuring of tensile bond strength, pairs of specimens within a group were bonded with Panavia 21 resin cement using special device secured that the film thickness was $80{\mu}m$. The results of tensile strength were statistically analyzed with the SPSS release version 8.0 programs. Physical change like surface roughness of In-Ceram alumina core treated by ion assistad reaction was evaluated by Contact Angle Measurement, Scanning Electron Microscopy, Atomic Force Microscopy; chemical surface change was evaluated by X-ray Photoelectron Spectroscopy. The results as follows: 1. In tensile bond strength, there were no statistically significant differences with SC group, IAR groups and SL group except control group(P<0.05). 2. Contact angle measurement showed that wettability of In-Ceram alumina core was enhanced after IAR treatment. 3. SEM and AFM showed that surface roughness of In-Ceram alumina core was not changed after IAR treatment. 4. XPS showed that IAR treatment of In-Ceram alumina core was enabled to create a new functional layer. A keV IAR treatment of In-Ceram alumina core could enhanced tensile bond strength with resin cement. In the future, this ion assisted reaction may be used effectively in various dental materials as well as in In-Ceram to promote the bond strength to natural tooth structure.

  • PDF