• 제목/요약/키워드: electrolyte solution

검색결과 775건 처리시간 0.085초

Multi-Functional Dual-Layer Polymer Electrolytes for Lithium Metal Polymer Batteries

  • Lee, Young-Gi;Ryu, Kwang-Sun;Chang, Soon-Ho
    • ETRI Journal
    • /
    • 제26권4호
    • /
    • pp.285-291
    • /
    • 2004
  • We prepared a novel multi-functional dual-layer polymer electrolyte by impregnating the interconnected pores with an ethylene carbonate (EC)/dimethyl carbonate (DMC)/lithium hexafluorophosphate $(LiPF_6)$ solution. The first layer, based on a microporous polyethylene, is incompatible with a liquid electrolyte, and the second layer, based on poly (vinylidenefluoride-co-hexafluoropropylene), is submicroporous and compatible with an electrolyte solution. The maximum ionic conductivity is $7{\times}10^{-3}S/cm$ at ambient temperature. A unit cell using the optimum polymer electrolyte showed a reversible capacity of 198 mAh/g at the 500th cycle, which was about 87% of the initial value.

  • PDF

강화상 나노입자의 용액 반응성이 구리 도금 박막에 미치는 영향 (Influence of Reactivity of Reinforcing Nanoparticles with Aqueous Solution on Electroplating Copper Films)

  • 박지은;오민주;김이슬;이동윤
    • 한국재료학회지
    • /
    • 제23권12호
    • /
    • pp.695-701
    • /
    • 2013
  • To understand how reactivity between reinforcing nanoparticles and aqueous solution affects electrodeposited Cu thin films, two types of commercialized cerium oxide (ceria, $CeO_2$) nanoparticles were used with copper sulfate electrolyte to form in-situ nanocomposite films. During this process, we observed variation in colors and pH of the electrolyte depending on the manufacturer. Ceria aqueous solution and nickel sulfate ($NiSO_4$) aqueous solutions were also used for comparison. We checked several parameters which could be key factors contributing to the changes, such as the oxidation number of Cu, chemical impurities of ceria nanoparticles, and so on. Oxidation number was checked by salt formation by chemical reaction between $CuSO_4$ solution and sodium hydroxide (NaOH) solution. We observed that the color changed when $H_2SO_4$ was added to the $CuSO_4$ solution. The same effect was obtained when $H_2SO_4$ was mixed with ceria solution; the color of ceria solution changed from white to yellow. However, the color of $NiSO_4$ solution did not show any significant changes. We did observe slight changes in the pH of the solutions in this study. We did not obtain firm evidence to explain the changes observed in this study, but changes in the color of the electrolyte might be caused by interaction of Cu ion and the by-product of ceria. The mechanical properties of the films were examined by nanoindentation, and reaction between ceria and electrolyte presumably affect the mechanical properties of electrodeposited copper films. We also examined their crystal structures and optical properties by X-ray diffraction (XRD) and UV-Vis spectroscopy.

금속-공기전지의 Anode전극 반응에 관한 연구 (Study on the Anode Electrode Reaction in the Metal-Air Cell)

  • 김용혁
    • 한국전기전자재료학회논문지
    • /
    • 제23권12호
    • /
    • pp.1002-1006
    • /
    • 2010
  • In this study, magnesium (Mg), zinc (Zn) and aluminium (Al) as anode electrode and the solution of NaCl dissolved with 2~20 wt% as electrolytes were used for the metal-air cell. The open circuit voltage, short circuit current and I-V characteristics upon different kinds of anode electrode and electrolyte concentration were investigated. The open circuit voltage, initially about 1.45 V, rises to 1.6 V during the first 10 minutes indicating the necessity of an induction time to activate the catalyst on the air cathode. The short circuit current increases with an increased concentration of NaCl, causes an increase in the conductivity of the electrolyte solution, but the open circuit voltage did not under undergo influence of electrolyte. From NaCl 20 wt% electrolyte, the maximum output power of the magnesium electrode materials was measured with 177mW. It is found that the power characteristics of metal-air cell could be improved by using magnesium electrode materials in the NaCl electrolyte.

전기 분해법을 이용한 다이아몬드 상 탄소 박막 증착에서의 암모니아수 첨가 효과 (Adding effect of ammonia solution on deposition of diamond phase carbon thin films by electrolysis method)

  • 권민철;김은미;박홍준;김용;이재열;신동혁
    • 한국진공학회지
    • /
    • 제8권4B호
    • /
    • pp.524-529
    • /
    • 1999
  • We deposited diamond phase carbon thin films on Si substrate by the electrolysis of methanol solution. A little amount of ammonia solution was added to increase the current density of the electrolyte. We analyzed films by XRD and SEM. The chemical change of electrolyte during the electrolysis process was characterized by FTIR. We obtained better quality diamond phase carbon films at a lower applying boltage(300V) and temperature ($40^{\circ}C$) by adding ammonia solution to methanol electrolyte. Diamond (111), (220), (311) peaks were shown distinctively in XRD graph. Addition of ammonia solution resulted in lowering the applying bias voltage to 300V and the substrate temperature to $40^{\circ}C$ still maintaining a high current density at 80mA/$\textrm{cm}^2$, which prohibited a great loss of solution from vaporization. Possible change of chemical reaction due to the addition of ammonia solution was also discussed.

  • PDF

헥사시아노 철산철 활물질의 전기화학적 특성에 미치는 전해질 농도의 영향 (Effects of Electrolyte Concentration on Electrochemical Properties of an Iron Hexacyanoferrate Active Material)

  • 양은지;이상엽;말도나도노잘레스폴;정순기
    • 융합정보논문지
    • /
    • 제11권2호
    • /
    • pp.117-123
    • /
    • 2021
  • 수계 아연 이온 전지의 신규 전극 활물질로서 헥사시아노 철산철(Fe4[Fe(CN6)]3, FeHCF)의 전기화학적 특성에 미치는 전해질 농도의 영향에 관하여 조사하였다. FeHCF 전극의 전기화학 반응 및 구조적 안정성에 전해질 농도가 크게 영향을 준다는 것이 전위 주사, 충전-방전 시험, X-선 회절 분석에 의해 확인되었다. 1.0-7.0 mol dm-3의 전해질 용액에서는 농도가 증가함에 따라 FeHCF 전극의 충전 및 방전 용량이 증가하였으나 사이클이 진행됨에 따라 서서히 감소하였다. 반면에 9.0 mol dm-3의 전해질 용액에서는 초기 용량은 상대적으로 작았으나 사이클 특성이 우수하였다. 전자의 전해질 용액에서 5사이클 진행된 FeHCF 전극은 반응 전과 비교하여 결정 구조에 변화가 있었으며, 후자의 경우에는 변화가 없었다. 이것은 FeHCF 전극의 전기화학적 성능이 전해질 용액 중에 존재하는 아연 이온의 수화 구조와 크게 관련이 있음을 시사하는 것이다.

전기화학적 방법에 의한 타이타늄 분극특성 및 나노메쉬 형성 (Characteristics of titanium polarization curve and formation of nanomesh by electrochemical method)

  • 박진서;김부섭
    • 대한치과기공학회지
    • /
    • 제38권2호
    • /
    • pp.79-84
    • /
    • 2016
  • Purpose: The aim of this study was to make nanomesh on the surface of titanium by potentiostatic technique which was done at the suitable potential level. Methods: In order to find the suitable potential level, use a $25^{\circ}C$ NaCl, NaOH and NH4F solution of 1 M and 5 M as supporting electrolyte, working electrode(positive potential) was contact to the titanium specimen and counter electrode(negative potential) was contact to the Pt substrate. At the transpassive potential which was observed by potentiostatic technique, potentiostatic technique was done for 2hours. Results: As a result, 1 M NaOH solution was suitable as a supporting electrolyte, potentiostatic technique used a $25^{\circ}C$ NaOH solution of 1 M for 2hours, nanomesh was formed. Conclusion: The potentiostatic technique was used $25^{\circ}C$ NaOH solution of 1 M and 5 M as supporting electrolyte for 2hours. Nanomesh was built more uniform and fine in 1 M NaOH solution than 5 M NaOH solution.

4 M KOH 수용액 및 에탄올 용액에서 알루미늄 공기 전지용 Al-(Ga, Sn, Mn) 합금 음극의 부식 특성 (Corrosion Properties of Al-(Ga, Sn, Mn) Alloy Anodes for an Al-air Battery in 4 M KOH Aqueous and Ethanol Solutions)

  • 이한옥;박찬진;장희진
    • Corrosion Science and Technology
    • /
    • 제10권2호
    • /
    • pp.71-75
    • /
    • 2011
  • Corrosion properties of Al-0.3Ga-0.3Sn, Al-0.3Mn-0.3Ga, and Al-0.3Mn-0.3Sn alloys were examined to develop an anode material for Al-air battery with alkaline aqueous or ethanol electrolyte. The results of potentiodynamic polarization tests showed that the electrode potential of the Al alloys were lower than the pure Al, implying the cell voltage can be increased by using one of these alloys for an anode in 4 M KOH aqueous solution. The corrosion rate appeared to be increased by alloying Ga but to be reduced by Sn and Mn in the aqueous solution. The ethanol solution is expected to improve the cell performance in that the electrode potential and the corrosion rate of Al were lower in ethanol solution than in aqueous solution. However the Al-(Ga, Sn, Mn) alloys are not favorable in ethanol solution because of the high potential and corrosion rate.

Al/Air 연료전지의 출력특성에 미치는 KOH 전해질과 H2O2 감극제의 영향 (Effect of KOH Electrolyte and H2O2 Depolarizer on the Power Characteristics of Al/Air Fuel Cells)

  • 김용혁
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.303-307
    • /
    • 2015
  • The effects of additive such as $H_2O_2$ in KOH electrolyte solution for the Aluminum/Air fuel cell were investigated with regard to electric power characteristics. The power generated by a Al/Air fuel cell was controlled by the KOH electrolyte solution and $H_2O_2$ depolarizer. Higher cell power was achieved when higher KOH electrolyte concentration and higher $H_2O_2$ depolarizer amount. The maximum power was increased by the increase amount $H_2O_2$ depolarizer, it was found that $H_2O_2$ depolarizer inhibits the generation of hydrogen and the polarization effect was reduced as a result. Internal resistance analysis was employed to elucidate the maximum power variation. Higher internal resistance created internal potential differences that drive current dissipating energy. In order to improve the output characteristics of the Al/Air fuel cell, it is thought to be desirable to increase the KOH electrolyte concentration and increase the $H_2O_2$ addition amounts.

Electrorefining of CuZr Alloy Using Ba2ZrF8-LiF Electrolyte

  • Lee, Seong Hun;Choi, Jeong Hun;Yoo, Bung Uk;Lee, Jong Hyeon
    • 한국재료학회지
    • /
    • 제27권12호
    • /
    • pp.672-678
    • /
    • 2017
  • In the production of zirconium cladding tube, a pickling acid solution is used to remove surface contaminants, which generates tons of pickling acid waste. The waste pickling solution is a valuable resource of Hf-free Zr. Many studies have investigated separating the Hf-free Zr source from the waste pickling acid. The results showed that $Ba_2ZrF_8$ precipitates prepared from the waste pickling acid were useful as an electrolyte for the electrorefining of Zr in molten salt. In the present work, electrorefining was performed in a $Ba_2ZrF_8-LiF$ binary electrolyte to recover Zr from a Hf-free CuZr ingot anode prepared by electroreduction. Before electrorefining, two pretreatments are performed. First, electrolyte melting was carried out to determine the eutectic temperature, and second, the electrolyte was treated to eliminate impurities, mainly hydride. After electrorefining, the cathode deposits were analyzed by $O_2$ gas analyzer and SEM-EDX to explore the possibility of recovering nuclear-grade Zr metal. Moreover, the anode was analyzed by SEM-EDX to determine the Zr dissolution depth.

구리/NaCl 전해질/아연 전기화학전지의 전류특성 (Current characteristics of Cu/NaCl electrolyte/Zn electrochemical cell)

  • 김용혁
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1626-1631
    • /
    • 2010
  • The characteristics of electric current for the voltaic cell are important for electric power applications. In this paper, an electrical equivalent model consist of three resisters and a capacitance for the Cu/NaCl solution/Zn electrochemical cell is proposed. The capacitance which exists in the Zn electrode/electrolytic interface increased according to Zn electrode area, but cannot affect almost in electric current. Complex impedance plot was used to analysis the interface effect for Zn/electrolyte. This result shows that the interface is similar with the electric transmission line. The short current measurements were conducted to investigate the effects of hydrogen peroxide, the watery sulfuric acid and NaCl aqueous solution. As the hydrogen peroxide increased, the electric current increased because the hydrogen gas being converted with the water. Also electric current increased significantly with increase of the hydrogen ion with the watery sulfuric acid and increased with increase of $Na^+$ ion and $Cl^-$ion in the NaCl electrolyte.